Night energy balance in a heated low-cost plastic greenhouse

被引:65
作者
Baille, A.
Lopez, J. C.
Bonachela, S.
Gonzalez-Real, M. M.
Montero, J. I.
机构
[1] Univ Politecn Cartagena, Area Ingn Agroforestal, Escuela Tecn Super Ingn Agron, Cartagena 30203, Spain
[2] Estac Expt Palmerillas Cajamar, El Ejido 04710, Almeria, Spain
[3] Univ Almeria, Dept Prod Vegetal, Almeria 04120, Spain
[4] IRTA, Barcelona 08348, Spain
关键词
heating system; energy balance; convective heat loss; radiative heat loss; heat transfer coefficient;
D O I
10.1016/j.agrformet.2006.03.008
中图分类号
S3 [农学(农艺学)];
学科分类号
0901 ;
摘要
This paper analyses the night energy balance of an air-heated greenhouse in mild-winter climatic conditions (Almeria, Southeastern Spain). The components of the energy balance of the air volume, soil and cover surfaces were determined in a low-cost plastic structure (parral-type), devoid of crop, under continuous and constant inflow of heat into the inside air at moderate (62 W m(-2)) and at high (134 W m(-2)) heating input. For typical winter weather conditions and heating practices in the Almeria region, corresponding to the moderate heating input, the energy balance at the soil-air interface showed that the soil heat flux provided most of the energy to compensate for the radiative ground losses, and only a very small amount of sensible energy, of the same order of magnitude as the residual soil evaporation (< 5 W m(-2)), was exchanged between the air and the soil surface. In the greenhouse air volume, energy losses mainly occurred through air-inner cover convective exchange (; 50 W m(-2)). At the cover, losses mostly occurred by radiative exchange, the convective component being relatively small (between 10 W m(-2)). For the high heating input, the soil radiative losses were compensated by both the soil conduction flux (about 15 W m(-2)) and the soil-to-air convective heat transfer (about 20 W m(-2)). Radiative losses were also found to be the major component of the cover losses, whereas the convective component reached one-third of the total cover loss. For the two heating levels, leakage losses reached up to 35% of the heating input at high wind speed. The increase in leakage losses with wind speed led to a consequential decrease of the cover convective fluxes and to a negative relationship between the latter and the wind speed. Estimates of the convective heat transfer coefficients between the inside air and surfaces (soil and inner cover), and between the outside air and the outer cover, supply values within the range reported in the literature. The influence of the air mixing due to the air heating systems on the inside air-to-cover heat coefficient was demonstrated. In conclusion the measures to improve the energy efficiency would be: (i) to improve the air tightness of the greenhouse, (ii) to reduce radiative losses by means of thermal screens or IR-opaque plastic covering materials, and (iii) to increase the soil efficiency in storing solar energy and releasing it during the night. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:107 / 118
页数:12
相关论文
共 28 条
[1]  
ALBRIGHT L, 1990, AM SOC AGR ENG, P453
[2]  
Bailey B. J., 1994, Computers and Electronics in Agriculture, V10, P203, DOI 10.1016/0168-1699(94)90041-8
[3]  
BAILEY BJ, 1988, FAO REUR TECHNICAL S, V3, P17
[4]  
BAILLE A, 1999, ECOSYSTEMS WORLD, V20, P265
[5]   Greenhouse ventilation rate: Theory and measurement with tracer gas techniques [J].
Baptista, FJ ;
Bailey, BJ ;
Randall, JM ;
Meneses, JF .
JOURNAL OF AGRICULTURAL ENGINEERING RESEARCH, 1999, 72 (04) :363-374
[6]   Mechanical properties of covering materials for greenhouses .2. General overview [J].
Briassoulis, D ;
Waaijenberg, D ;
Gratraud, J ;
vonEslner, B .
JOURNAL OF AGRICULTURAL ENGINEERING RESEARCH, 1997, 67 (02) :81-96
[7]  
BRUTSAERT W, 1984, EVAPORATION ATMOSPHE, P290
[8]   A review of greenhouse engineering developments during the 1990s [J].
Critten, DL ;
Bailey, BJ .
AGRICULTURAL AND FOREST METEOROLOGY, 2002, 112 (01) :1-22
[9]  
DAY W, 1999, ECOSYSTEMS WORLD, V20, P71
[10]  
de Halleux D., 1989, THESIS GEMBLOUX U BE