Effects of continuous positive airway pressure on sleep apnea and ventricular irritability in patients with heart failure

被引:245
作者
Javaheri, S
机构
[1] Univ Cincinnati, Med Ctr, Dept Med, Cincinnati, OH 45267 USA
[2] Dept Vet Affairs Med Ctr, Sleep Disorders Lab, Cincinnati, OH USA
关键词
nervous system; sympathetic; heart failure; respiration hypoxia;
D O I
10.1161/01.CIR.101.4.392
中图分类号
R5 [内科学];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
Background-Patients with heart failure and systolic dysfunction may develop disordered breathing during sleep. Repeated episodes of apnea and hypopnea may result in desaturation and arousals, which could adversely affect left ventricular function. The purpose of this study was to determine the short-term effects of continuous positive airway pressure (CPAP) on sleep-disordered breathing and its consequences in heart failure patients. Methods and Results-The author prospectively studied 29 male patients whose initial polysomnograms showed 15 or more episodes of apnea and hypopnea per hour (apnea-hypopnea index, AHI). Twenty-one patients had predominately central and 8 patients obstructive sleep apnea. All were treated with CPAP during the subsequent night. In 16 patients, CPAP resulted in virtual elimination of disordered breathing. In these patients, the mean AHI (36 +/- 12 [SD] versus 4 +/- 3 per hour, P = 0.0001), arousal index due to disordered breathing (16 +/- 9 versus 2 +/- 2 per hour, P = 0.0001), and percent of total sleep time below saturation of 90% (20 +/- 23% to 0.3 +/- 0.7%, P = 0.0001) decreased, and lowest saturation (76 +/- 8% versus 90 +/- 3%, P = 0.0001) increased with CPAP. In 13 patients who did not respond to CPAP, these values did not change significantly. In patients whose sleep apnea responded to CPAP, the number of hourly episodes of nocturnal premature ventricular contractions (66 +/- 117 versus 18 +/- 20. P = 0.055) and couplets (3.2 +/- 6 versus 0.2 +/- 0.21, P = 0.031) decreased. In contrast, in patients whose sleep apnea did not respond to CPAP, ventricular arrhythmias did not change significantly. Conclusions-In 55% of patients with heart failure and sleep apnea, first-night nasal CPAP eliminates disordered breathing and reduces ventricular irritability.
引用
收藏
页码:392 / 397
页数:6
相关论文
共 27 条
[1]
[Anonymous], 1992, SLEEP, V15, P174
[2]
PHARYNGEAL NARROWING OCCLUSION DURING CENTRAL SLEEP-APNEA [J].
BADR, MS ;
TOIBER, F ;
SKATRUD, JB ;
DEMPSEY, J .
JOURNAL OF APPLIED PHYSIOLOGY, 1995, 78 (05) :1806-1815
[3]
Bradley T D, 1996, J Card Fail, V2, P223, DOI 10.1016/S1071-9164(96)80045-5
[4]
THE EFFECT OF SHORT-TERM NASAL CPAP ON CHEYNE-STOKES RESPIRATION IN CONGESTIVE-HEART-FAILURE [J].
BUCKLE, P ;
MILLAR, T ;
KRYGER, M .
CHEST, 1992, 102 (01) :31-35
[5]
NASAL CONTINUOUS POSITIVE AIRWAY PRESSURE IN CHRONIC HEART-FAILURE WITH SLEEP-DISORDERED BREATHING [J].
DAVIES, RJO ;
HARRINGTON, KJ ;
ORMEROD, OJM ;
STRADLING, JR .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1993, 147 (03) :630-634
[6]
ARTERIAL BLOOD-PRESSURE RESPONSES TO GRADED TRANSIENT AROUSAL FROM SLEEP IN NORMAL HUMANS [J].
DAVIES, RJO ;
BELT, PJ ;
ROBERTS, SJ ;
ALI, NJ ;
STRADLING, JR .
JOURNAL OF APPLIED PHYSIOLOGY, 1993, 74 (03) :1123-1130
[7]
Dempsey JA, 1996, SLEEP, V19, P236
[8]
CHEYNE-STOKES RESPIRATION PRESENTING AS SLEEP-APNEA SYNDROME - CLINICAL AND POLYSOMNOGRAPHIC FEATURES [J].
DOWDELL, WT ;
JAVAHERI, S ;
MCGINNIS, W .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1990, 141 (04) :871-879
[9]
GOLD AR, 1985, AM REV RESPIR DIS, V132, P220
[10]
REVERSAL OF CENTRAL SLEEP-APNEA USING NASAL CPAP [J].
ISSA, FG ;
SULLIVAN, CE .
CHEST, 1986, 90 (02) :165-171