Fast PC-based data acquisition system for gas-tilled position sensitive detectors

被引:9
作者
Mio, H [1 ]
Chemloul, M [1 ]
Laggner, P [1 ]
Amenitsch, H [1 ]
Bernstorff, S [1 ]
Rappolt, M [1 ]
机构
[1] SINCROTRONE TRIESTE,I-34012 TRIESTE,ITALY
关键词
D O I
10.1016/S0168-9002(97)00203-9
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The high flux of the new generation of synchrotron radiation sources requires fast position sensitive detectors with high count rate data acquisition systems capability. Though the local count rare in a gas-filled position-sensitive detector is limited by the space charge effect, the integral rate will increase with the area of the detector. Thus, more than several 10(6) events per second can be achieved. Therefore, we developed a new PC-based histogramming and control interface (HCl) with an intrinsic dead lime lower than 200 ns for linear and area X-ray detectors for time-resolved measurement applications. An overview of the complete acquisition system including a fast lime-to-digital converter and image processing software will be given. The design principles and operating characteristics including experimental results obtained with a 100 mm linear delay-line detector at the SAXS beamline 5.2 in Elettra (Trieste) will be presented.
引用
收藏
页码:384 / 391
页数:8
相关论文
共 23 条
[1]   HIGH-FLUX BEAMLINE FOR SMALL-ANGLE X-RAY-SCATTERING AT ELETTRA [J].
AMENITSCH, H ;
BERNSTORFF, S ;
LAGGNER, P .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (02) :1624-1626
[2]   X-RAY POSITION-SENSITIVE DETECTORS [J].
ARNDT, UW .
JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1986, 19 :145-163
[3]   DESIGN AND PROPERTIES OF POSITION-SENSITIVE PROPORTIONAL-COUNTERS USING RESISTANCE-CAPACITANCE POSITION ENCODING [J].
BORKOWSKI, CJ ;
KOPP, MK .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1975, 46 (08) :951-962
[4]   DATA ACQUISITION-SYSTEMS FOR LINEAR AND AREA X-RAY-DETECTORS USING DELAY-LINE READOUT [J].
BOULIN, CJ ;
KEMPF, R ;
GABRIEL, A ;
KOCH, MHJ .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 269 (01) :312-320
[5]  
CHARPAK DG, 1978, NUCL INSTRUM METHODS, V152, P185
[6]   A HIGH-RESOLUTION AND FAST TDC FOR SENSITIVE POSITION GAS-FILLED DETECTORS [J].
CHEMLOUL, M ;
COMPARAT, V .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 355 (2-3) :532-536
[7]   A new type of centroid finding method for position sensitive detectors [J].
Chemloul, M ;
Comparat, V .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 367 (1-3) :290-294
[8]   ALTERNATIVE APPROACHES TO DELAY-LINE READOUT FOR MULTIWIRE PROPORTIONAL CHAMBERS [J].
CIPRIANI, F ;
GABRIEL, A ;
KOCH, MHJ .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 346 (1-2) :286-291
[10]  
EIKENBERRY EF, 1991, ADV ELECT ELECT PHYS