Cerebral Protection During Transcatheter Aortic Valve Implantation: An Updated Systematic Review and Meta-Analysis

被引:34
作者
Testa, Luca [1 ]
Latib, Azeem [2 ]
Casenghi, Matteo [1 ]
Gorla, Riccardo [1 ]
Colombo, Antonio [2 ]
Bedogni, Francesco [1 ]
机构
[1] IRCCS Pol S Donato, Dept Cardiol, Milan, Italy
[2] EMO GVM Ctr Cuore Columbus, San Raffaele Sci Inst, Intervent Cardiol Unit, Milan, Italy
来源
JOURNAL OF THE AMERICAN HEART ASSOCIATION | 2018年 / 7卷 / 10期
基金
美国国家卫生研究院;
关键词
aortic valve stenosis; stroke; transcutaneous aortic valve implantation; EMBOLIC DEFLECTION DEVICE; BRAIN-LESIONS; REPLACEMENT; RISK; STENOSIS; SILENT; EMBOLIZATION;
D O I
10.1161/JAHA.117.008463
中图分类号
R5 [内科学];
学科分类号
100201 [内科学];
摘要
Background-The use of embolic protection devices (EPD) may theoretically reduce the occurrence of cerebral embolic lesions during transcatheter aortic valve implantation. Available evidence from single studies is inconclusive. The aim of the present meta-analysis was to assess the safety and efficacy profile of current EPD. Methods and Results-Major medical databases were searched up to December 2017 for studies that evaluated patients undergoing transcatheter aortic valve implantation with or without EPD. End points of interest were 30-day mortality, 30-day stroke, the total number of new lesions, the ischemic volume per lesion, and the total volume of lesions. Eight studies involving 1285 patients were included. The EPD delivery success rate was reported in all studies and was achieved in 94.5% of patients. The use of EPD was not associated with significant differences in terms of 30-day mortality (odds ratio 0.43 [0.18-1.05], P=0.3) but it was associated with a lower rate of 30-day stroke (odds ratio 0.55 [0.31-0.98], P=0.04). No differences were detected with respect to the number of new lesions (standardized mean difference -0.19 [-0.71 to 0.34], P=0.49). The use of EPD was associated with a significantly smaller ischemic volume per lesion (standardized mean difference, -0.52 [-0.85 to -0.20], P=0.002) and smaller total volume of lesions (standardized mean difference, -0.23 [-0.42 to -0.03], P=0.02). Conclusions-The use of EPD is not associated with a reduced rate of mortality and new ischemic cerebral lesions. The use of EPD during transcatheter aortic valve implantation seems to be associated with a lower 30-day stroke rate, although this result is driven by a single nonrandomized study. The use of EPD is associated with a smaller volume of ischemic lesions, and smaller total volume of ischemic lesions.
引用
收藏
页数:14
相关论文
共 28 条
[1]
Transcatheter Aortic-Valve Replacement with a Self-Expanding Prosthesis [J].
Adams, David H. ;
Popma, Jeffrey J. ;
Reardon, Michael J. ;
Yakubov, Steven J. ;
Coselli, Joseph S. ;
Deeb, G. Michael ;
Gleason, Thomas G. ;
Buchbinder, Maurice ;
Hermiller, James, Jr. ;
Kleiman, Neal S. ;
Chetcuti, Stan ;
Heiser, John ;
Merhi, William ;
Zorn, George ;
Tadros, Peter ;
Robinson, Newell ;
Petrossian, George ;
Hughes, G. Chad ;
Harrison, J. Kevin ;
Conte, John ;
Maini, Brijeshwar ;
Mumtaz, Mubashir ;
Chenoweth, Sharla ;
Oh, Jae K. .
NEW ENGLAND JOURNAL OF MEDICINE, 2014, 370 (19) :1790-1798
[2]
[Anonymous], COCHRANE HDB SYSTEMA
[3]
Cerebral ischemic lesions on diffusion-weighted imaging are associated with neurocognitive decline after cardiac surgery [J].
Barber, P. Alan ;
Hach, Sylvia ;
Tippett, Lynette J. ;
Ross, Linda ;
Merry, Alan F. ;
Milsom, Paget .
STROKE, 2008, 39 (05) :1427-1433
[4]
Postcardiac surgical cognitive impairment in the aged using diffusion-weighted magnetic resonance imaging [J].
Cook, David J. ;
Huston, John, III ;
Trenerry, Max R. ;
Brown, Robert D., Jr. ;
Zehr, Kenton J. ;
Sundt, Thoralf M., III .
ANNALS OF THORACIC SURGERY, 2007, 83 (04) :1389-1395
[5]
Diffusion-weighted MRI determined cerebral embolic infarction following transcatheter aortic valve implantation: assessment of predictive risk factors and the relationship to subsequent health status [J].
Fairbairn, Timothy A. ;
Mather, Adam N. ;
Bijsterveld, Petra ;
Worthy, Gillian ;
Currie, Stuart ;
Goddard, Anthony J. P. ;
Blackman, Daniel J. ;
Plein, Sven ;
Greenwood, John P. .
HEART, 2012, 98 (01) :18-23
[6]
Clinically silent cerebral ischemic events after cardiac surgery: Their incidence, regional vascular occurrence, and procedural dependence [J].
Floyd, TF ;
Shah, PN ;
Price, CC ;
Harris, F ;
Ratcliffe, SJ ;
Acker, MA ;
Bavaria, JE ;
Rahmouni, H ;
Kuersten, B ;
Wiegers, S ;
McGarvey, ML ;
Woo, JY ;
Pochettino, AA ;
Melhem, ER .
ANNALS OF THORACIC SURGERY, 2006, 81 (06) :2160-2166
[7]
Risk and Fate of Cerebral Embolism After Transfemoral Aortic Valve Implantation A Prospective Pilot Study With Diffusion-Weighted Magnetic Resonance Imaging [J].
Ghanem, Alexander ;
Mueller, Andreas ;
Naehle, Claas P. ;
Kocurek, Justine ;
Werner, Nikos ;
Hammerstingl, Christoph ;
Schild, Hans H. ;
Schwab, Joerg O. ;
Mellert, Fritz ;
Fimmers, Rolf ;
Nickenig, Georg ;
Thomas, Daniel .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (14) :1427-1432
[8]
The Problem With Asymptomatic Cerebral Embolic Complications in Vascular Procedures What If They Are Not Asymptomatic? [J].
Gress, Daryl R. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 60 (17) :1614-1616
[9]
Effect of a Cerebral Protection Device on Brain Lesions Following Transcatheter Aortic Valve Implantation in Patients With Severe Aortic Stenosis The CLEAN-TAVI Randomized Clinical Trial [J].
Haussig, Stephan ;
Mangner, Norman ;
Dwyer, Michael G. ;
Lehmkuhl, Lukas ;
Luecke, Christian ;
Woitek, Felix ;
Holzhey, David M. ;
Mohr, Friedrich W. ;
Gutberlet, Matthias ;
Zivadinov, Robert ;
Schuler, Gerhard ;
Linke, Axel .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2016, 316 (06) :592-601
[10]
Cerebral Embolization During Transcatheter Aortic Valve Implantation A Transcranial Doppler Study [J].
Kahlert, Philipp ;
Al-Rashid, Fadi ;
Doettger, Philipp ;
Mori, Kathrine ;
Plicht, Bjoern ;
Wendt, Daniel ;
Bergmann, Lars ;
Kottenberg, Eva ;
Schlamann, Marc ;
Mummel, Petra ;
Holle, Dagny ;
Thielmann, Matthias ;
Jakob, Heinz G. ;
Konorza, Thomas ;
Heusch, Gerd ;
Erbel, Raimund ;
Eggebrecht, Holger .
CIRCULATION, 2012, 126 (10) :1245-+