Determination of theobromine, theophylline and caffeine in cocoa samples by a high-performance liquid chromatographic method with on-line sample cleanup in a switching-column system

被引:137
作者
Brunetto, Maria del Rosario
Gutierrez, Lubin
Delgado, Yelitza
Gallignani, Maximo
Zambrano, Alexis
Gomez, Alvaro
Ramos, Gladys
Romero, Carlos
机构
[1] Univ Los Andes, Fac Sci, IVAIQUIM Venezuelan Andean Inst Chem Res, Merida 5101, Venezuela
[2] Minist Agr & Tierras, Inst Nacl Invest Agr, Merida 5101, Venezuela
关键词
cocoa; theobromine; caffeine; theophylline; HPLC; solid-phase extraction; column-switching;
D O I
10.1016/j.foodchem.2005.10.007
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
A simple reversed-phase high-performance liquid chromatographic method was developed for the determination of theobromine, theophylline and caffeine in cocoa samples. In the sample cleanup step, the procedure involves an on-line solid-phase extraction of analytes from cocoa samples into a home-made dry-packed pre-column with ODS-C-18 using a column-switching system. The separation was performed on a C-18 Nova-Pak column (150 nim x 3.9 mm, 4 mu m) using a mobile phase consisting of a solution of 20% of methanol in water under isocratic conditions, at a flow-rate of 1.4 ml/min. The validation method revealed quantitative recoveries (> 95.0%) with a coefficients of variation < 3.2% and it also provided a good precision for data validation. The overlap of sample cleanup, analysis and recondition of the precolumn increases the sample throughput to 8 samples/h. Furthermore, the proposed method was successfully applied to analysis of cocoa samples "Trinitario", "Forastero" and "Criollo" grown in different seasons of the year and fermented for 3 and 7 days, respectively. The results showed a slight reduction in the theobromine and caffeine content according to the fermentation times. In the same way, the theobromine/caffeine ratio was assessed, with the purpose of establishing a correlation with the genotype of the studied samples. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:459 / 467
页数:9
相关论文
共 25 条
[1]   Simultaneous determination of caffeine, theobromine, and theophylline by high-performance liquid chromatography [J].
Bispo, MS ;
Veloso, MCC ;
Pinheiro, HLC ;
De Oliveira, RFS ;
Reis, JON ;
De Andrade, JB .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2002, 40 (01) :45-48
[2]   HPLC ANALYSIS OF METHYLXANTHINES IN HUMAN BREAST-MILK [J].
BLANCHARD, J ;
WEBER, CW ;
SHEARER, LE .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1990, 28 (12) :640-642
[3]   Developmental variation of sugars, carboxylic acids, purine alkaloids, fatty acids, and endoproteinase activity during maturation of Theobroma cacao L. seeds [J].
Bucheli, P ;
Rousseau, G ;
Alvarez, M ;
Laloi, M ;
McCarthy, J .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2001, 49 (10) :5046-5051
[4]   Improved analysis of theobromine and caffeine in chocolate food products formulated with cocoa powder [J].
Caudle, AG ;
Gu, YF ;
Bell, LN .
FOOD RESEARCH INTERNATIONAL, 2001, 34 (07) :599-603
[5]   Simultaneous determination of caffeine, theobromine and theophylline in foods and pharmaceutical preparations by using ion chromatography [J].
Chen, Q ;
Mou, S ;
Hou, X ;
Ni, Z .
ANALYTICA CHIMICA ACTA, 1998, 371 (2-3) :287-296
[6]   Simultaneous determination of artificial sweeteners, preservatives, caffeine, theobromine and theophylline in food and pharmaceutical preparations by ion chromatography [J].
Chen, QC ;
Wang, J .
JOURNAL OF CHROMATOGRAPHY A, 2001, 937 (1-2) :57-64
[7]  
Davrieux F., 2005, 14 INT COCOA RES C, P861
[8]   QUANTIFICATION OF THEOPHYLLINE IN HUMAN PLASMA BY REVERSED-PHASE ION-INTERACTION HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND COMPARISON WITH THE TDX FLUORESCENCE POLARIZATION IMMUNOASSAY PROCEDURE [J].
GENNARO, MC ;
ABRIGO, C ;
BIGLINO, P .
ANALYST, 1992, 117 (07) :1071-1074
[9]   CAFFEINE AND THEOBROMINE IN COFFEE, TEA AND COLA-BEVERAGES - SIMULTANEOUS DETERMINATION BY REVERSED-PHASE ION-INTERACTION HPLC [J].
GENNARO, MC ;
ABRIGO, C .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1992, 343 (06) :523-525
[10]   HIGHLY SENSITIVE AND RAPID-DETERMINATION OF THEOPHYLLINE, THEOBROMINE AND CAFFEINE IN HUMAN PLASMA AND URINE BY GRADIENT CAPILLARY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY FRIT-FAST ATOM BOMBARDMENT MASS-SPECTROMETRY [J].
HIEDA, Y ;
KASHIMURA, S ;
HARA, K ;
KAGEURA, M .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1995, 667 (02) :241-246