Controlled release, blind tests of DNAPL characterization using partitioning tracers

被引:43
作者
Brooks, MC
Annable, MD
Rao, PSC
Hatfield, K
Jawitz, JW
Wise, WR
Wood, AL
Enfield, CG
机构
[1] Univ Florida, Interdisciplinary Program Hydrol Sci, Gainesville, FL 32611 USA
[2] US EPA, Natl Risk Management Res Lab, Cincinnati, OH 45268 USA
[3] US EPA, Natl Risk Management Res Lab, Ada, OK 74820 USA
[4] Purdue Univ, Sch Civil Engn, W Lafayette, IN 47907 USA
关键词
tracer test; partitioning tracer; DNAPL; perchloroethylene; groundwater; site characterization;
D O I
10.1016/S0169-7722(02)00057-8
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The partitioning tracer technique for dense nonaqueous phase liquid (DNAPL) characterization was evaluated in an isolated test cell, in which controlled releases of perchloroethylene (PCE) had occurred. Four partitioning tracer tests were conducted, two using an inverted, double five-spot pumping pattern, and two using vertical circulation wells. Two of the four tests were conducted prior to remedial activities, and two were conducted after. Each test was conducted as a "blind test" where researchers conducting the partitioning tracer tests had no knowledge of the volume, method of release, nor resulting spatial distribution of DNAPL. Multiple partitioning tracers were used in each test, and the DNAPL volume estimates varied significantly within each test based on the different partitioning tracers. The tracers with large partitioning coefficients generally predicted a smaller volume of PCE than that expected based on the actual release volume. However, these predictions were made for low DNAPL saturations (average saturation was approximately 0.003), under conditions near the limits of the method's application. Furthermore, there were several factors that may have hindered prediction accuracy, including tracer degradation and remedial fluid interference. (C) 2002 Published by Elsevier Science B.V.
引用
收藏
页码:187 / 210
页数:24
相关论文
共 40 条
[1]   Partitioning tracers for measuring residual NAPL: Field-scale test results [J].
Annable, MD ;
Rao, PSC ;
Hatfield, K ;
Graham, WD ;
Wood, AL ;
Enfield, CG .
JOURNAL OF ENVIRONMENTAL ENGINEERING, 1998, 124 (06) :498-503
[2]  
ANNABLE MD, 1995, 2 TRAC WORKSH I EN T, P77
[3]  
[Anonymous], [No title captured], Patent No. [3,590,923, 3590923]
[4]  
BROOKS MC, THESIS U FLORIDA GAI
[5]   Thermodynamics of bromide exchange on ferrihydrite: Implications for bromide transport [J].
Brooks, SC ;
Taylor, DL ;
Jardine, PM .
SOIL SCIENCE SOCIETY OF AMERICA JOURNAL, 1998, 62 (05) :1275-1279
[6]  
Brusseau ML, 1999, ACS SYM SER, V725, P208
[7]   Partitioning tracer tests for evaluating remediation performance [J].
Cain, RB ;
Johnson, GR ;
McCray, JE ;
Blanford, WJ ;
Brusseau, ML .
GROUND WATER, 2000, 38 (05) :752-761
[8]   Using vertical circulation wells for partitioning tracer tests and remediation of DNAPLs [J].
Chen, L ;
Knox, RC .
GROUND WATER MONITORING AND REMEDIATION, 1997, 17 (03) :161-168
[9]   Partitioning and interfacial tracers for differentiating NAPL entrapment configuration: Column-scale investigation [J].
Dai, DP ;
Barranco, FT ;
Illangasekare, TH .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2001, 35 (24) :4894-4899
[10]  
Deans H., 1971, U.S. Patent, Patent No. [3623842, 3,623,842]