Type of Hip Fracture Determines Load Share in Intramedullary Osteosynthesis

被引:73
作者
Eberle, Sebastian [1 ]
Gerber, Claus [2 ]
von Oldenburg, Geert [2 ]
Hungerer, Sven [1 ]
Augat, Peter [1 ]
机构
[1] Trauma Ctr Murnau, Inst Biomech, D-82418 Murnau, Germany
[2] Stryker Osteosynth, Schoenkirchen Kiel, Germany
关键词
FINITE-ELEMENT-ANALYSIS; UNSTABLE INTERTROCHANTERIC FRACTURES; HUMAN PROXIMAL FEMUR; BIOMECHANICAL EVALUATION; FEMORAL FRACTURES; PLATE; NAIL; VALIDATION; MORTALITY; WALKING;
D O I
10.1007/s11999-009-0800-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
The choice of the appropriate implant continues to be critical for fixation of unstable hip fractures. Therefore, the goal of this study was to develop a numerical model to investigate the mechanical performance of hip fracture osteosynthesis. We hypothesized that decreasing fracture stability results in increasing load share of the implant and therefore higher stress within the implant. We also investigated the relationship of interfragmentary movement to the fracture stability. A finite element model was developed for a cephalomedullary nail within a synthetic femur and simulated a pertrochanteric fracture, a lateral neck fracture, and a subtrochanteric fracture. The femur was loaded with a hip force and was constrained physiologically. The FE model was validated by mechanical experiments. All three fractures resulted in similar values for stiffness (462-528 N/mm). The subtrochanteric fracture resulted in the highest local stress (665 MPa), and the pertrochanteric fracture resulted in a lower stress (621 MPa) with even lower values for the lateral neck fracture (480 MPa). Thus, intramedullary implants can stabilize unstable hip fractures with almost the same amount of stiffness as seen in stable fractures, but they have to bear a higher load share, resulting in higher stresses in the implant.
引用
收藏
页码:1972 / 1980
页数:9
相关论文
共 31 条
[1]
Implant-related complications in the treatment of unstable intertrochanteric fractures:: meta-analysis of dynamic screw-plate versus dynamic screw-intramedullary nail devices [J].
Audigé, L ;
Hanson, B ;
Swiontkowski, MF .
INTERNATIONAL ORTHOPAEDICS, 2003, 27 (04) :197-203
[2]
Hip contact forces and gait patterns from routine activities [J].
Bergmann, G ;
Deuretzbacher, G ;
Heller, M ;
Graichen, F ;
Rohlmann, A ;
Strauss, J ;
Duda, GN .
JOURNAL OF BIOMECHANICS, 2001, 34 (07) :859-871
[3]
A BIOMECHANICAL EVALUATION OF THE LONG STEM INTRAMEDULLARY HIP SCREW [J].
BOSTROM, MPG ;
LYDEN, JP ;
ERNBERG, JJ ;
MISSRI, AAE ;
BERBERIAN, WS .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1995, 9 (01) :45-52
[4]
Outcome of osteoporotic pelvic fractures: An underestimated severity. Survey of 60 cases [J].
Breuil, Veronique ;
Roux, Christian Hubert ;
Testa, Jean ;
Albert, Christine ;
Chassang, Madleen ;
Brocq, Olivier ;
Euller-Ziegler, Liana .
JOINT BONE SPINE, 2008, 75 (05) :585-588
[5]
CHANG WS, 1987, CLIN ORTHOP RELAT R, P141
[6]
Finite element analysis of a femoral retrograde intramedullary nail subject to gait loading [J].
Cheung, G ;
Zalzal, P ;
Bhandari, M ;
Spelt, JK ;
Papini, M .
MEDICAL ENGINEERING & PHYSICS, 2004, 26 (02) :93-108
[7]
Fracture toughness and fatigue crack propagation rate of short fiber reinforced epoxy composites for analogue cortical bone [J].
Chong, Alexander C. M. ;
Miller, Forrest ;
Buxton, Mckee ;
Friis, Elizabeth A. .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2007, 129 (04) :487-493
[8]
Fatigue performance of composite analogue femur constructs under high activity loading [J].
Chong, Alexander C. M. ;
Friis, Elizabeth A. ;
Ballard, Gregory P. ;
Czuwala, Peter J. ;
Cooke, Francis W. .
ANNALS OF BIOMEDICAL ENGINEERING, 2007, 35 (07) :1196-1205
[9]
HIP-FRACTURES IN THE ELDERLY - A WORLDWIDE PROJECTION [J].
COOPER, C ;
CAMPION, G ;
MELTON, LJ .
OSTEOPOROSIS INTERNATIONAL, 1992, 2 (06) :285-289
[10]
Functional outcomes and mortality vary among different types of hip fractures - A function of patient characteristics [J].
Cornwall, R ;
Gilbert, MS ;
Koval, KJ ;
Strauss, E ;
Siu, AL .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (425) :64-71