An improved assay by HPLC with amperometric detection for the determination of phentolamine in plasma

被引:5
作者
Pérez-Urizar, J [1 ]
Aguirre-Bañuelos, P [1 ]
Castañeda-Hernández, G [1 ]
Flores-Murrieta, F [1 ]
机构
[1] Inst Politecn Nacl, Ctr Invest & Estudios Avanzados, Dept Farmacol & Toxicol, Mexico City 14000, DF, Mexico
关键词
D O I
10.1081/JLC-100101472
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An improved method for the determination of phentolamine in human plasma samples was developed. After being alkalinized, plasma samples (1 mL) were extracted with diethyl ether and then back-extracted with O.1 N HCl. Analyses were carried out on a Novapak C8 column eluted with a mixture of sodium monochloroacetate (pH 3) and acetonitrile (75:25). Amperometric detection was performed by oxidation at 1000 mV, using a glassy carbon electrode against Ag/AgCl. Calibration curves, constructed over a 1 to 30 ng/mL plasma concentration range, were linear (r=0.999). Intra-assay coefficients of variation and accuracy for the determined concentrations were comprised within 7.6-10.9% and 94.0-105.6%, respectively. Inter-assay coefficient of variation and accuracy ranges were 10.4-20.7% and 93.2-102.7%, respectively. The methods detection limit was 0.2 ng/mL, allowing determination of oral phentolamine pharmacokinetics after administration of a 40 mg dose. It is concluded that the present procedure is suitable for pharmacokinetic and bioavailability studies of oral phentolamine formulations presently used in the treatment of erectile dysfunction.
引用
收藏
页码:557 / 564
页数:8
相关论文
共 6 条
[1]   Oral phentolamine as treatment for erectile dysfunction [J].
Becker, AJ ;
Stief, CG ;
Machtens, S ;
Schultheiss, D ;
Hartmann, U ;
Truss, MC ;
Jonas, U .
JOURNAL OF UROLOGY, 1998, 159 (04) :1214-1215
[2]   DETERMINATION OF PHENTOLAMINE IN BLOOD AND URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
BROS, FD ;
WOLSHIN, EM .
ANALYTICAL CHEMISTRY, 1978, 50 (03) :521-525
[3]  
Hoffman BB, 1996, The pharmacological basis of therapeutics, P199
[4]   AN ASSAY FOR PHENTOLAMINE USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION [J].
KERGER, BD ;
JAMES, RC ;
ROBERTS, SM .
ANALYTICAL BIOCHEMISTRY, 1988, 170 (01) :145-151
[5]   GAS-CHROMATOGRAPHIC DETERMINATION OF PHENTOLAMINE (REGITINE) IN HUMAN-PLASMA AND URINE [J].
SIOUFI, A ;
POMMIER, F ;
MANGONI, P ;
GAURON, S ;
METAYER, JP .
JOURNAL OF CHROMATOGRAPHY, 1981, 222 (03) :429-435
[6]  
Zorgniotti A W, 1994, Int J Impot Res, V6, P37