A multiple active contour model for cardiac boundary detection on echocardiographic sequences

被引:239
作者
Chalana, V
Linker, DT
Haynor, DR
Kim, YM
机构
[1] UNIV WASHINGTON, CTR BIOENGN, SEATTLE, WA 98195 USA
[2] UNIV WASHINGTON, DIV CARDIOL, SEATTLE, WA 98195 USA
[3] UNIV WASHINGTON, DEPT RADIOL, SEATTLE, WA 98195 USA
[4] UNIV WASHINGTON, DEPT ELECT ENGN, SEATTLE, WA 98195 USA
关键词
D O I
10.1109/42.500138
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Tracing of left-ventricular epicardial and endocardial borders on echocardiographic sequences is essential for quantification of cardiac function. We designed a method based on an extension of active contour models to detect both epicardial and endocardial borders on short-axis cardiac sequences spanning the entire cardiac cycle, We validated the results by comparing the computer-generated boundaries to the boundaries manually outlined by four expert observers on 44 clinical data sets, The mean boundary distance between the computer-generated boundaries and the manually outlined boundaries was 2.80 mm (sigma = 1.28 mm) for the epicardium and 3.61 (sigma = 1.68 mm) for the endocardium, These distances were comparable to interobserver distances, which had a mean of 3.79 mm (sigma = 1.53 mm) for epicardial borders and 2.67 mm (sigma = 0.88 mm) for endocardial borders, The correlation coefficient between the areas enclosed by the computer-generated boundaries and the average manually outlined boundaries was 0.95 for epicardium and 0.91 for endocardium, The algorithm is fairly insensitive to the choice of the initial curve, Thus, we have developed an effective and robust algorithm to extract left-ventricular boundaries from echocardiographic sequences.
引用
收藏
页码:290 / 298
页数:9
相关论文
共 24 条
[1]  
[Anonymous], 1983, THESIS MIT CAMBRIDGE
[2]  
CHALANA V, 1995, PROC SPIE, V2434, P262
[3]  
CHALANA V, 1994, P SOC PHOTO-OPT INS, V2167, P786, DOI 10.1117/12.175117
[4]  
CHALANA V, UNPUB ACAD RADIOL
[5]   DETECTING LEFT-VENTRICULAR ENDOCARDIAL AND EPICARDIAL BOUNDARIES BY DIGITAL TWO-DIMENSIONAL ECHOCARDIOGRAPHY [J].
CHU, CH ;
DELP, EJ ;
BUDA, AJ .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1988, 7 (02) :81-90
[6]   ON ACTIVE CONTOUR MODELS AND BALLOONS [J].
COHEN, LD .
CVGIP-IMAGE UNDERSTANDING, 1991, 53 (02) :211-218
[7]   FINITE-ELEMENT METHODS FOR ACTIVE CONTOUR MODELS AND BALLOONS FOR 2-D AND 3-D IMAGES [J].
COHEN, LD ;
COHEN, I .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1993, 15 (11) :1131-1147
[8]   REPRODUCIBILITY OF LEFT-VENTRICULAR AREA AND VOLUME MEASUREMENTS USING A COMPUTER ENDOCARDIAL EDGE-DETECTION ALGORITHM IN NORMAL SUBJECTS [J].
CONETTA, DA ;
GEISER, EA ;
OLIVER, LH ;
MILLER, AB ;
CONTI, CR .
AMERICAN JOURNAL OF CARDIOLOGY, 1985, 56 (15) :947-952
[9]  
DANIEL WW, 1978, APPLIED NONPARAMETRI
[10]   MATCHED-FILTER IDENTIFICATION OF LEFT-VENTRICULAR ENDOCARDIAL BORDERS IN TRANSESOPHAGEAL ECHOCARDIOGRAMS [J].
DETMER, PR ;
BASHEIN, G ;
MARTIN, RW .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1990, 9 (04) :396-404