The effects of polymer properties on DNA separations by capillary electrophoresis in uncross-linked polymer solutions

被引:115
作者
Barron, AE [1 ]
Sunada, WM [1 ]
Blanch, HW [1 ]
机构
[1] UNIV CALIF BERKELEY,DEPT CHEM,BERKELEY,CA 94720
关键词
capillary electrophoresis; DNA restriction fragments; polyacrylamide; hydroxyethylcellulose; hydroxypropylcellulose;
D O I
10.1002/elps.1150170421
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Low-viscosity, aqueous solutions of hydrophilic linear polymers have been shown to be useful for the separation of DNA restriction fragments by capillary electrophoresis (CE). However, the choice of polymer type, size, and concentration remains largely empirical, because the mechanism of high-field electrophoretic DNA separations in polymer solutions is not well understood. To assist in elucidating the mechanism of DNA separation, we experimentally investigated the effects of polymer properties such as stiffness (persistence length), average molecular mass, polydispersity, and hydrophilicity on the separation of DNA ranging from 72 bp to 23 kbp. This was accomplished by comparing the results of DNA separations obtained by counter-migration CE in dilute and semidilute solutions of linear polyacrylamide (PAA), hydroxyethylcellulose (HEC), and hydroxypropylcellulose (HPC) polymers of several different average molecular masses.
引用
收藏
页码:744 / 757
页数:14
相关论文
共 42 条
  • [1] HIGH-RESOLUTION SEPARATION OF DNA RESTRICTION FRAGMENTS BY CAPILLARY ELECTROPHORESIS IN CELLULOSE DERIVATIVE SOLUTIONS
    BABA, Y
    ISHIMARU, N
    SAMATA, K
    TSUHAKO, M
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1993, 653 (02) : 329 - 335
  • [2] BARNES HA, 1989, INTRO RHEALOGY
  • [3] THE USE OF COATED AND UNCOATED CAPILLARIES FOR THE ELECTROPHORETIC SEPARATION OF DNA IN DILUTE POLYMER-SOLUTIONS
    BARRON, AE
    SUNADA, WM
    BLANCH, HW
    [J]. ELECTROPHORESIS, 1995, 16 (01) : 64 - 74
  • [4] CAPILLARY ELECTROPHORESIS OF DNA IN UNCROSS-LINKED POLYMER-SOLUTIONS
    BARRON, AE
    SOANE, DS
    BLANCH, HW
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1993, 652 (01) : 3 - 16
  • [5] A TRANSIENT ENTANGLEMENT COUPLING MECHANISM FOR DNA SEPARATION BY CAPILLARY ELECTROPHORESIS IN ULTRADILUTE POLYMER-SOLUTIONS
    BARRON, AE
    BLANCH, HW
    SOANE, DS
    [J]. ELECTROPHORESIS, 1994, 15 (05) : 597 - 615
  • [6] BASHKIN JS, 1995, 17 INT S CAP CHROM E
  • [7] CAPILLARY ELECTROPHORESIS OF DNA IN AGAROSE SOLUTIONS AT 40-DEGREES-C
    BOCEK, P
    CHRAMBACH, A
    [J]. ELECTROPHORESIS, 1991, 12 (12) : 1059 - 1061
  • [8] BUTLER JM, 1994, BIOTECHNIQUES, V17, P4
  • [9] SEPARATION OF DNA RESTRICTION FRAGMENTS USING CAPILLARY ELECTROPHORESIS
    CHAN, KC
    WHANG, CW
    YEUNG, ES
    [J]. JOURNAL OF LIQUID CHROMATOGRAPHY, 1993, 16 (9-10): : 1941 - 1962
  • [10] MOVEMENT OF DNA FRAGMENTS DURING CAPILLARY ZONE ELECTROPHORESIS IN LIQUID POLYACRYLAMIDE
    CHIARI, M
    NESI, M
    RIGHETTI, PG
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1993, 652 (01) : 31 - 39