In today's high-throughput screening (HTS) environment, an increasing number of assay detection technologies are routinely utilized in lead finding programs. Because of the relatively broad applicability of several of these technologies, one is often faced with a choice of which technology to utilize for a specific assay. The aim of this study was to address the question of whether the same compounds would be identified from screening a set of samples in three different versions of an HTS assay. Here, three different versions of a tyrosine kinase assay were established using scintillation proximity assay (SPA), homogeneous time-resolved fluorescence resonance energy transfer (HTR-FRET), and fluorescence polarization (FP) technologies. In this study, 30,000 compounds were evaluated in each version of the kinase assay in primary screening, deconvolution, and dose-response experiments. From this effort, there was only a small degree of overlap of active compounds identified subsequent to the deconvolution experiment. When all active compounds were then profiled in all three assays, 100 and 101 active compounds were identified in the HTR-FRET and FP assays, respectively. In contrast, 40 compounds were identified in the SPA version of the kinase assay, whereas all of these compounds were detected in the HTR-FRET assay only 35 were active in the FP assay. Although there was good correlation between the IC50 values obtained in the HTR-FRET and FP assays, poor correlations were obtained with the IC50 values obtained in the SPA assay. These findings suggest that significant differences can be observed from HTS depending on the assay technology that is utilized, particularly in assays with high hit rates.
引用
收藏
页码:191 / 214
页数:24
相关论文
共 12 条
[1]   Scintillation proximity assay: A versatile high-throughput screening technology [J].
Cook, ND .
DRUG DISCOVERY TODAY, 1996, 1 (07) :287-294
[2]   Evaluation of electrochemiluminescent technology for inhibitors of granulocyte colony-stimulating factor receptor binding [J].
Gopalakrishnan, SM ;
Warrior, U ;
Burns, D ;
Groebe, DR .
JOURNAL OF BIOMOLECULAR SCREENING, 2000, 5 (05) :369-375
[3]   Time-resolved fluorometry: an overview of the labels and core technologies for drug screening applications [J].
Hemmila, I ;
Webb, S .
DRUG DISCOVERY TODAY, 1997, 2 (09) :373-381
[4]  
Jolley ME, 1996, J BIOMOL SCREEN, V1, P33
[5]  
KIBBEY M, 1996, NAT BIOTECHNOL, V14, P259
[6]   Rapid and sensitive immunomagnetic-electrochemiluminescent detection of staphyloccocal enterotoxin B [J].
Kijek, TM ;
Rossi, CA ;
Moss, D ;
Parker, RW ;
Henchal, EA .
JOURNAL OF IMMUNOLOGICAL METHODS, 2000, 236 (1-2) :9-17
[7]  
Kolb J.M., 1996, J BIOMOL NMR, V1, P203
[8]  
MATHIS G, 1995, CLIN CHEM, V41, P1391
[9]   Fluorescence polarization and anisotropy in high throughput screening: Perspectives and primer [J].
Owicki, JC .
JOURNAL OF BIOMOLECULAR SCREENING, 2000, 5 (05) :297-306
[10]  
SELVIN PR, 1995, METHOD ENZYMOL, V246, P300