Sequential binding of CD11a/CD18 and CD11b/CD18 defines neutrophil capture and stable adhesion to Intercellular adhesion molecule-1

被引:114
作者
Hentzen, ER
Neelamegham, S
Kansas, GS
Benanti, JA
McIntire, LV
Smith, CW
Simon, SI
机构
[1] Baylor Coll Med, Dept Pediat, Speros Martel Sect Leukocyte Biol, Houston, TX 77030 USA
[2] Rice Univ, Cox Lab Biomed Engn, Inst Biosci & Bioengn, Houston, TX 77251 USA
[3] SUNY Buffalo, Dept Chem Engn, Buffalo, NY 14260 USA
[4] Northwestern Univ, Sch Med, Dept Microbiol & Immunol, Chicago, IL USA
关键词
D O I
10.1182/blood.V95.3.911.003k36_911_920
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The relative contributions of CD11a/CD18 and CD11b/CD18 to the dynamics and strength of neutrophil adhesion to intercellular adhesion molecule (ICAM)-1-transfected cells were examined over the time course of chemotactic stimulation. Suspensions of neutrophils and transfectants were sheared in a cone-plate viscometer, and formation of heterotypic aggregates was measured by 2-color flow cytometry. The 2-body collision theory was used to compute adhesion efficiency, defined as the proportion of collisions between neutrophils and target cells that resulted in capture. ICAM-1 surface density and shear rate both regulated adhesion efficiency, Target cells expressing approximately 1000 ICAM-1 sites/mu m(2)(I-low) were captured with an efficiency of 0.15 at 100 s(-1), which decreased to zero at 300 s(-1). At 8-fold higher ICAM-1 expression (I-high) corresponding to levels measured on interleukin-1-stimulated endothelium, efficiency was 0.3 at 100 s(-1) and remained above background to 900 s(-1) Shear alone was sufficient for CD11a/CD18-mediated adhesion to ICAM-1, and stimulation with formyl-methionyl-leucyl-phenylalanine boosted capture efficiency through CD11a/CD18 by 4-fold. In comparison, CD11b/CD18 supported one third of this efficiency, but was necessary for aggregate stability over several minutes of shear and at shear stresses exceeding 5 dyne/cm(2). Hydrodynamics influenced capture efficiency predominantly through the collisional contact duration, predicted to be approximately 9 milliseconds for successful capture of I-low and 4 milliseconds for I-high The implication is that an increase in ICAM-1 from resting levels to those on inflamed endothelium effectively increases the permissible shear in which capture through beta(2)-integrins may occur. Neutrophil adhesion to ICAM-1 appears to be a cooperative and sequential process of CD11a-dependent capture followed by CD11b-mediated stabilization. (C) 2000 by The American Society of Hematology.
引用
收藏
页码:911 / 920
页数:10
相关论文
共 46 条
  • [1] E-SELECTIN SUPPORTS NEUTROPHIL ROLLING IN-VITRO UNDER CONDITIONS OF FLOW
    ABBASSI, O
    KISHIMOTO, TK
    MCINTIRE, LV
    ANDERSON, DC
    SMITH, CW
    [J]. JOURNAL OF CLINICAL INVESTIGATION, 1993, 92 (06) : 2719 - 2730
  • [2] [Anonymous], PHYS BASIS CELL CELL
  • [3] BELL GI, 1978, SCIENCE, V200, P618, DOI 10.1126/science.347575
  • [4] GENERATION OF SIGNALS ACTIVATING NEUTROPHIL FUNCTIONS BY LEUKOCYTE INTEGRINS - LFA-1 AND GP150/95, BUT NOT CR3, ARE ABLE TO STIMULATE THE RESPIRATORY BURST OF HUMAN NEUTROPHILS
    BERTON, G
    LAUDANNA, C
    SORIO, C
    ROSSI, F
    [J]. JOURNAL OF CELL BIOLOGY, 1992, 116 (04) : 1007 - 1017
  • [5] LEUKOCYTE-ENDOTHELIAL CELL RECOGNITION - 3 (OR MORE) STEPS TO SPECIFICITY AND DIVERSITY
    BUTCHER, EC
    [J]. CELL, 1991, 67 (06) : 1033 - 1036
  • [6] Chemokines and the arrest of lymphocytes rolling under flow conditions
    Campbell, JJ
    Hedrick, J
    Zlotnik, A
    Siani, MA
    Thompson, DA
    Butcher, EC
    [J]. SCIENCE, 1998, 279 (5349) : 381 - 384
  • [7] Doerschuk CM, 1996, J IMMUNOL, V157, P4609
  • [8] LYMPHOCYTE FUNCTION ASSOCIATED ANTIGEN-1 (LFA-1) INTERACTION WITH INTERCELLULAR-ADHESION MOLECULE-1 (ICAM-1) IS ONE OF AT LEAST 3 MECHANISMS FOR LYMPHOCYTE ADHESION TO CULTURED ENDOTHELIAL-CELLS
    DUSTIN, ML
    SPRINGER, TA
    [J]. JOURNAL OF CELL BIOLOGY, 1988, 107 (01) : 321 - 331
  • [9] NEUTROPHIL INDUCED OXIDATIVE INJURY OF CARDIAC MYOCYTES - A COMPARTMENTED SYSTEM REQUIRING CD11B CD18-ICAM-1 ADHERENCE
    ENTMAN, ML
    YOUKER, K
    SHOJI, T
    KUKIELKA, G
    SHAPPELL, SB
    TAYLOR, AA
    SMITH, CW
    [J]. JOURNAL OF CLINICAL INVESTIGATION, 1992, 90 (04) : 1335 - 1345
  • [10] Fung Y. C., 1993, BIOMECHANICS MECH PR