Quantitative analysis of single bacterial chemotaxis using a linear concentration gradient microchannel

被引:35
作者
Jeon, Hojeong [4 ]
Lee, Yongku [4 ]
Jin, Songwan [3 ]
Koo, Sangmo [4 ]
Lee, Chang-Soo [2 ]
Yoo, Jung Yul [1 ,4 ]
机构
[1] Seoul Natl Univ, Inst Adv Machinery & Design, Seoul 151744, South Korea
[2] Chungnam Natl Univ, Dept Chem Engn, Taejon 305764, South Korea
[3] Korea Polytech Univ, Dept Mech Engn, Siheung Si 429793, Gyeonggi Do, South Korea
[4] Seoul Natl Univ, Sch Mech & Aerosp Engn, Seoul 151744, South Korea
关键词
Chemotaxis; Bacteria; Microchannel; Linear concentration gradient; Hydrodynamic focusing; MICROFLUIDIC DEVICE; RANDOM MOTILITY; DIFFUSION; COEFFICIENTS; ASSAY;
D O I
10.1007/s10544-009-9330-8
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A microfluidic device to quantify bacterial chemotaxis has been proposed, which generates a linear concentration gradient of chemoattractant in the main channel only by convective and molecular diffusion, and which enables the bacteria to enter the main channel in a single file by hydrodynamic focusing technique. The trajectory of each bacterium in response to the concentration gradient of chemoattractant is photographed by a CCD camera and its velocity is acquired by a simple PTV (Particle Tracking Velocimetry) algorithm. An advantage of this assay is to measure the velocity of a single bacterium and to quantify the degree of chemotaxis by analyzing the frequency of velocities concurrently. Thus, the parameter characterizing the motility of wild-type Escherichia coli strain RP437 in response to various concentration gradients of L-aspartate is obtained in such a manner that the degree of bacterial chemotaxis is quantified on the basis of a newly proposed Migration Index.
引用
收藏
页码:1135 / 1143
页数:9
相关论文
共 20 条
[1]   CHEMOTAXIS IN BACTERIA [J].
ADLER, J .
SCIENCE, 1966, 153 (3737) :708-&
[2]   CHEMOTAXIS IN BACTERIA [J].
BERG, HC .
ANNUAL REVIEW OF BIOPHYSICS AND BIOENGINEERING, 1975, 4 :119-136
[3]   Spectral intensity mapping and analysis of dyed microflows [J].
Curran, K ;
Davies, M .
MICROFLUIDICS AND NANOFLUIDICS, 2005, 1 (02) :146-154
[4]   A three-channel microfluidic device for generating static linear gradients and its application to the quantitative analysis of bacterial chemotaxis [J].
Diao, JP ;
Young, L ;
Kim, S ;
Fogarty, EA ;
Heilman, SM ;
Zhou, P ;
Shuler, ML ;
Wu, MM ;
DeLisa, MP .
LAB ON A CHIP, 2006, 6 (03) :381-388
[5]   MEASUREMENT OF BACTERIAL RANDOM MOTILITY AND CHEMOTAXIS COEFFICIENTS .1. STOPPED-FLOW DIFFUSION CHAMBER ASSAY [J].
FORD, RM ;
PHILLIPS, BR ;
QUINN, JA ;
LAUFFENBURGER, DA .
BIOTECHNOLOGY AND BIOENGINEERING, 1991, 37 (07) :647-660
[6]   MEASUREMENT OF BACTERIAL RANDOM MOTILITY AND CHEMOTAXIS COEFFICIENTS .2. APPLICATION OF SINGLE-CELL-BASED MATHEMATICAL-MODEL [J].
FORD, RM ;
LAUFFENBURGER, DA .
BIOTECHNOLOGY AND BIOENGINEERING, 1991, 37 (07) :661-672
[7]   Generating fixed concentration arrays in a microfluidic device [J].
Holden, MA ;
Kumar, S ;
Castellana, ET ;
Beskok, A ;
Cremer, PS .
SENSORS AND ACTUATORS B-CHEMICAL, 2003, 92 (1-2) :199-207
[8]   Neutrophil chemotaxis in linear and complex gradients of interleukin-8 formed in a microfabricated device [J].
Jeon, NL ;
Baskaran, H ;
Dertinger, SKW ;
Whitesides, GM ;
Van de Water, L ;
Toner, M .
NATURE BIOTECHNOLOGY, 2002, 20 (08) :826-830
[9]   Optical measurement of transverse molecular diffusion in a microchannel [J].
Kamholz, AE ;
Schilling, EA ;
Yager, P .
BIOPHYSICAL JOURNAL, 2001, 80 (04) :1967-1972
[10]   Enhanced diffusion due to motile bacteria [J].
Kim, MJ ;
Breuer, KS .
PHYSICS OF FLUIDS, 2004, 16 (09) :L78-L81