Time-resolved luminescence energy transfer immunobinding study using a ruthenium-ligand complex as a donor label

被引:13
作者
Augustin, CM [1 ]
Oswald, B [1 ]
Wolfbeis, OS [1 ]
机构
[1] Univ Regensburg, Inst Analyt Chem Chemo & Biosensors, D-93040 Regensburg, Germany
关键词
luminescence immunoassay; time resolution; luminescence decay time; resonance energy transfer (RET); fluorescent labels; ruthenium labels;
D O I
10.1006/abio.2002.5633
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A novel immunosystem is described that exploits the effect of luminescence energy transfer from a luminescently labeled antigen to a fluorescent antibody. A luminescent ruthenium-ligand complex (D-455) with absorption/emission maxima at 456/639 nm, respectively, was employed as the donor label, and a squaraine-type cyanine label (636/655 nm), as the fluorescent acceptor label. Specifically, the system human serum albumin (HSA)/anti-HSA was studied. HSA was labeled with the donor dye D-455, and anti-HSA was labeled with the acceptor dye A-631. On formation of the antigen-antibody complex, energy transfer occurs. The radiationless energy transfer affects both the decay time of D-455 and the intensities of the emissions of both D-455 and A-631. The decay time of around 500 ns of D-455 allows frequency-domain measurements in the low kilohertz range and therefore can be based on the use of conventional optoelectronics. This also suggests gated measurements to be performed. The major difference from existing HSA immunosystems is the use of a slow decaying ruthenium-ligand complex as the donor and of a long-wave emitting cyanine acceptor dye having a high quantum yield and a decay kinetics that is governed by the rate of energy transfer from the slow decaying donor. (C) 2002 Elsevier Science (USA).
引用
收藏
页码:166 / 172
页数:7
相关论文
共 17 条
[1]  
Alpha-Bazin B, 2001, SPR S FLUOR, V1, P439
[2]  
DEMAS JN, 1971, J PHYS CHEM-US, V75, P991, DOI 10.1021/j100678a001
[3]  
Diamandis E.P., 1996, IMMUNOASSAY
[4]   Anomalous fluorescence enhancement of Cy3 and Cy3.5 versus anomalous fluorescence loss of Cy5 and Cy7 upon covalent linking to IgG and noncovalent binding to avidin [J].
Gruber, HJ ;
Hahn, CD ;
Kada, G ;
Riener, CK ;
Harms, GS ;
Ahrer, W ;
Dax, TG ;
Knaus, HG .
BIOCONJUGATE CHEMISTRY, 2000, 11 (05) :696-704
[5]   4',5'-DIMETHOXY-6-CARBOXYFLUORESCEIN - A NOVEL DIPOLE-DIPOLE COUPLED FLUORESCENCE ENERGY-TRANSFER ACCEPTOR USEFUL FOR FLUORESCENCE IMMUNOASSAYS [J].
KHANNA, PL ;
ULLMAN, EF .
ANALYTICAL BIOCHEMISTRY, 1980, 108 (01) :156-161
[6]  
KRICKA LJ, 1991, CLIN CHEM, V37, P1472
[7]   Synthesis and luminescence spectral characterization of long-lifetime lipid metal-ligand probes [J].
Li, L ;
Szmacinski, H ;
Lakowicz, JR .
ANALYTICAL BIOCHEMISTRY, 1997, 244 (01) :80-85
[8]   TIME-RESOLVED DETECTION OF ENERGY-TRANSFER - THEORY AND APPLICATION TO IMMUNOASSAYS [J].
MORRISON, LE .
ANALYTICAL BIOCHEMISTRY, 1988, 174 (01) :101-120
[9]   Red laser-induced fluorescence energy transfer in an immunosystem [J].
Oswald, B ;
Lehmann, F ;
Simon, L ;
Terpetschnig, E ;
Wolfbeis, OS .
ANALYTICAL BIOCHEMISTRY, 2000, 280 (02) :272-277
[10]  
Oswald B, 2001, PHOTOCHEM PHOTOBIOL, V74, P237, DOI 10.1562/0031-8655(2001)074<0237:NDLCFA>2.0.CO