Near-infrared dyes for six-color immunophenotyping by laser scanning cytometry

被引:41
作者
Gerstner, AOH
Lenz, D
Laffers, W
Hoffman, RA
Steinbrecher, M
Bootz, F
Tárnok, A
机构
[1] Univ Leipzig, Cardiac Ctr, Dept Otorhinolaryngol Plast Surg, D-04289 Leipzig, Germany
[2] Univ Leipzig, Cardiac Ctr, Leipzig, Germany
[3] BD Biosci, San Jose, CA USA
[4] Caltag Labs GmbH, Hamburg, Germany
来源
CYTOMETRY | 2002年 / 48卷 / 03期
关键词
immunophenotyping; laser scanning cytometry; multiparametric analysis; slide-based cytometry; minimal sample volume; cyanine; 7; tandem dyes;
D O I
10.1002/cyto.10119
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: To adequately analyze the complexity of the immune system and reduce the required sample volume for immunophenotyping in general, more measurable colors for the discrimination of leukocyte subsets are necessary. Immunophenotyping by the laser scanning cytometer (LSC), a slide-based cytometric technology, combines cell detection based on multiple colors with their subsequent visualization without the need for physical cell sorting. In the present study, the filter setting of the LSC was adapted for the measurement of the far-red emitting dye cyanine 7 (Cy7), thereby increasing the number of measurable commercially available fluorochromes. Methods: The optical filters of the LSC were replaced-photomultiplier (PMT)3/allophycocyanin (APC): 740-nm dichroic long pass, and 670-/55-nm bandpass; PMT 4/Cy7:810-/90-nm bandpass. Peripheral blood leukocytes were stained directly by fluorochrome-labeled antibodies or by indirect staining. The tandem dyes of Cy7 (phycoerythrin [PE]-Cy7, APC-Cy7) and the fluorochromes fluorescein isothiocyanate (FITC), PE, PE-Cy5, and APC were tested alone and in different combinations. Results: With the new filter combination and tandem fluorochromes, Cy7 was measurable at 488-nm (argon laser) or 633-nm (helium-neon laser) excitation. Resolution was in the range of FITC for PE-Cy7 but approximately 30% lower for APC-Cy7; spillover into the respective donor fluorochrome channel for both tandem dyes was prominent. A six-color panel for leukocyte subtyping was designed. Conclusions: With this adaptation, it is possible to measure the tandem conjugates PE-Cy7 and APC-Cy7. This new setup opens the way for six-color immunophenotyping by LSC. Cytometry 48:115-123, 2002. (C) 2002 Wiley-Liss, Inc.
引用
收藏
页码:115 / 123
页数:9
相关论文
共 35 条
[1]  
Beavis AJ, 1996, CYTOMETRY, V24, P390
[2]  
Bedner E, 1999, CYTOMETRY, V36, P77, DOI 10.1002/(SICI)1097-0320(19990501)36:1<77::AID-CYTO10>3.3.CO
[3]  
2-6
[4]  
Bedner E, 2001, CYTOMETRY, V43, P38, DOI 10.1002/1097-0320(20010101)43:1<38::AID-CYTO1017>3.3.CO
[5]  
2-J
[6]  
Clatch RJ, 1998, CYTOMETRY, V34, P36, DOI 10.1002/(SICI)1097-0320(19980215)34:1<36::AID-CYTO6>3.3.CO
[7]  
2-0
[8]   11-color, 13-parameter flow cytometry: Identification of human naive T cells by phenotype, function, and T-cell receptor diversity [J].
De Rosa, SC ;
Herzenberg, LA ;
Herzenberg, LA ;
Roederer, M .
NATURE MEDICINE, 2001, 7 (02) :245-248
[9]   BDCA-2, BDCA-3 and BDCA-4: Three markers for distinct subsets of dendritic cells in human peripheral blood [J].
Dzionek, A ;
Fuchs, A ;
Schmidt, P ;
Cremer, S ;
Zysk, M ;
Miltenyi, S ;
Buck, DW ;
Schmitz, J .
JOURNAL OF IMMUNOLOGY, 2000, 165 (11) :6037-6046
[10]   Immunophenotyping of peripheral blood leukocytes by laser scanning cytometry [J].
Gerstner, A ;
Laffers, W ;
Bootz, F ;
Tárnok, A .
JOURNAL OF IMMUNOLOGICAL METHODS, 2000, 246 (1-2) :175-185