EVALUATION OF ONYX HD-500 EMBOLIC SYSTEM IN THE TREATMENT OF 84 WIDE-NECK INTRACRANIAL ANEURYSMS

被引:6
作者
Piske, Ronie L. [1 ]
Kanashiro, Luis H. [1 ]
Paschoal, Eric [1 ]
Agner, Celso [2 ]
Lima, Sergio S. [1 ]
Aguiar, Paulo H. [3 ]
机构
[1] Hosp Beneficencia Portuguesa Sao Paulo, Sect Intervent Neuroradiol, BR-01323001 Sao Paulo, Brazil
[2] Advocate Trinity Hosp, Dept Neurol, Chicago, IL USA
[3] Univ Sao Paulo, Sch Med, Dept Neurol, Div Neurosurg, Sao Paulo, Brazil
关键词
Aneurysm; Guglielmi detachable coils; Onyx; Recurrence; Wide neck; CELLULOSE-ACETATE POLYMER; MATRIX DETACHABLE COILS; ANGIOGRAPHIC FOLLOW-UP; UNIVERSITY-OF-ILLINOIS; ENDOVASCULAR TREATMENT; CEREBRAL ANEURYSMS; ARTERIOVENOUS-MALFORMATIONS; SUBARACHNOID HEMORRHAGE; CLINICAL-EXPERIENCE; SACCULAR ANEURYSMS;
D O I
10.1227/01.NEU.0000339108.17736.72
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE: We report our results using Onyx HD-500 (Micro Therapeutics, Inc., Irvine, CA) in the endovascular treatment of wide-neck intracranial aneurysms, which have a high rate of incomplete occlusion and recanalization with platinum coils. METHODS: Sixty-nine patients with 84 aneurysms were treated. Most of the aneurysms were located in the anterior circulation (80 of 84 aneurysms), were unruptured (74 of 84 aneurysms), and were incidental. Ten presented with subarachnoid hemorrhage, and 15 were symptomatic. All aneurysms had wide necks (neck >4 mm and/or dome-to-neck ratio <1.5). Fifty aneurysms were small (<12 mm), 30 were large (12 to <25 mm) and 4 were giant. Angiographic follow-up was available for 65 of the 84 aneurysms at 6 months, for 31 of the 84 aneurysms at 18 months, and for 5 of the 84 aneurysms at 36 months. RESULTS: Complete aneurysm occlusion was seen in 65.5% of aneurysms on immediate control, in 84.6% at 6 months, and in 90.3% at 18 months. The rates of complete occlusion were 74%, 95.1%, and 95.2% for small aneurysms and 53.3%, 70%, and 80% for large aneurysms at the same follow-up periods. Progression from incomplete to complete occlusion was seen in 68.2% of all aneurysms, with a higher percentage in small aneurysms (90.9%). Aneurysm recanalization was observed in 3 patients (4.6%), with retreatment in 2 patients (3.3%). Procedural mortality was 2.9%. Overall morbidity was 7.2%. CONCLUSION: Onyx embolization of intracranial wide-neck aneurysms is safe and effective. Morbidity and mortality rates are similar to those of other current endovascular techniques. Larger samples and longer follow-up periods are necessary.
引用
收藏
页码:865 / 874
页数:10
相关论文
共 49 条
[1]   The remodeling technique of balloon-assisted Guglielmi detachable coil placement in wide-necked aneurysms: experience at the University of Illinois at Chicago [J].
Aletich, VA ;
Debrun, GM ;
Misra, M ;
Charbel, F ;
Ausman, JI .
JOURNAL OF NEUROSURGERY, 2000, 93 (03) :388-396
[2]   Effects of timing of coil embolization after aneurysmal subarachnoid hemorrhage on procedural morbidity and outcomes [J].
Baltsavias, GS ;
Byrne, JV ;
Halsey, J ;
Coley, SC ;
Sohn, MJ ;
Molyneux, AJ .
NEUROSURGERY, 2000, 47 (06) :1320-1329
[3]  
Berenstein A, 2006, AM J NEURORADIOL, V27, P1834
[4]   Intrasaccular combination of metallic coils and Onyx liquid embolic agent for the endovascular treatment of cerebral aneurysms [J].
Cekirge, H. Saruhan ;
Saatci, Isil ;
Geyik, Serdar ;
Yavuz, Kivilcim ;
Ozturk, Halil ;
Pamuk, Gulsun .
JOURNAL OF NEUROSURGERY, 2006, 105 (05) :706-712
[5]   Late angiographic and clinical follow-up results of 100 consecutive aneurysms treated with Onyx reconstruction: largest single-center experience [J].
Cekirge, HS ;
Saatci, I ;
Ozturk, MH ;
Cil, B ;
Arat, A ;
Mawad, M ;
Ergungor, F ;
Belen, D ;
Er, U ;
Turk, S ;
Bavbek, M ;
Sekerci, Z ;
Beskonakli, E ;
Ozcan, OE ;
Ozgen, T .
NEURORADIOLOGY, 2006, 48 (02) :113-126
[6]  
Chyatte D., 2003, Management of Cerebral Aneurysms, P89
[7]   Long-term angiographic follow-up of 169 intracranial berry aneurysms occluded with detachable coils [J].
Cognard, C ;
Weill, A ;
Spelle, L ;
Piotin, M ;
Castaings, L ;
Rey, A ;
Moret, J .
RADIOLOGY, 1999, 212 (02) :348-356
[8]   Late angiographic follow-up review of surgically treated aneurysms [J].
David, CA ;
Vishteh, AG ;
Spetzler, RF ;
Lemole, M ;
Lawton, MT ;
Partovi, S .
JOURNAL OF NEUROSURGERY, 1999, 91 (03) :396-401
[9]   Aneurysm geometry: An important criterion in selecting patients for Guglielmi detachable coiling [J].
Debrun, GM ;
Aletich, VA ;
Kehrli, P ;
Misra, M ;
Ausman, JI ;
Charbel, F ;
Shownkeen, H .
NEUROLOGIA MEDICO-CHIRURGICA, 1998, 38 :1-20
[10]   Selection of cerebral aneurysms for treatment using Guglielmi detachable coils: The preliminary university of Illinois at chicago experience [J].
Debrun, GM ;
Aletich, VA ;
Kehrli, P ;
Misra, M ;
Ausman, JI ;
Charbel, F .
NEUROSURGERY, 1998, 43 (06) :1281-1295