The limits of the separation power of unidimensional column liquid chromatography

被引:143
作者
Guiochon, Georges [1 ]
机构
[1] Univ Tennessee, Dept Chem, Knoxville, TN 37996 USA
[2] Oak Ridge Natl Lab, Div Chem & Analyt Sci, Oak Ridge, TN 37831 USA
基金
美国国家科学基金会;
关键词
bed heterogeneity; column efficiency; efficiency; flow velocity; friction; gradient elution; isocratic elution; peak capacity; pressure; retention times; thermal effects;
D O I
10.1016/j.chroma.2006.07.032
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The practical limit of the separation power of HPLC depends on time, money, and skill. That is it depends on the time available for the analysis, on the quality and performance of the pump and hardware and particularly on the maximum pressure at which the pump can deliver the mobile phase to the column, and on the temperature at which the column can be operated. It also depends on the properties of the packing material selected (e.g., its particle size, its pore geometry, and its connectivity) and on the packing method used since it affects the coefficients of the HETP equation. Finally, it depends on the thermal stability of the sample and the packing material. The complexity of the sample also plays an important role in that it determines whether the analysis should be made under isocratic, isothermal conditions, in gradient elution, in temperature programming, or with a combination of both types of programming. The various phenomena that affect column properties and separation performance are discussed. Past achievements suggest that columns providing efficiencies in excess of a million plates in less than 1 day are within the grasp of current technology. The possibility of further advances are considered. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:6 / 49
页数:44
相关论文
共 238 条
[1]   Determination of the porosities of monolithic columns by inverse size-exclusion chromatography [J].
Al-Bokari, M ;
Cherrak, D ;
Guiochon, G .
JOURNAL OF CHROMATOGRAPHY A, 2002, 975 (02) :275-284
[2]  
[Anonymous], HPLC 2006
[3]  
[Anonymous], J HIGH RESOLUT CHROM, DOI DOI 10.1002/JHRC.1240040607
[4]  
[Anonymous], 1956, FONTAINES PUBLIQUES
[5]  
ANTIA FD, 1988, J CHROMATOGR, V435, P1
[6]   ON THE DISPERSION OF A SOLUTE BY DIFFUSION, CONVECTION AND EXCHANGE BETWEEN PHASES [J].
ARIS, R .
PROCEEDINGS OF THE ROYAL SOCIETY OF LONDON SERIES A-MATHEMATICAL AND PHYSICAL SCIENCES, 1959, 252 (1271) :538-550
[7]   ON THE DISPERSION OF A SOLUTE IN A FLUID FLOWING THROUGH A TUBE [J].
ARIS, R .
PROCEEDINGS OF THE ROYAL SOCIETY OF LONDON SERIES A-MATHEMATICAL AND PHYSICAL SCIENCES, 1956, 235 (1200) :67-77
[8]  
BAKAJIN O, 2006, SCIENCE, V312, P1034
[9]   MICROCYLINDER ELECTRODES AS SENSITIVE DETECTORS FOR HIGH-EFFICIENCY, HIGH-SPEED LIQUID-CHROMATOGRAPHY [J].
BAUR, JE ;
WIGHTMAN, RM .
JOURNAL OF CHROMATOGRAPHY, 1989, 482 (01) :65-73
[10]   RADIAL DISPERSION FROM COMMERCIAL HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY COLUMNS INVESTIGATED WITH MICROVOLTAMMETRIC ELECTRODES [J].
BAUR, JE ;
KRISTENSEN, EW ;
WIGHTMAN, RM .
ANALYTICAL CHEMISTRY, 1988, 60 (21) :2334-2338