Translumbar type II endoleak repair using angiographic CT

被引:52
作者
Binkert, Christoph A. [1 ]
Alencar, Herlen [1 ]
Singh, Jai [1 ]
Baum, Richard A. [1 ]
机构
[1] Brigham & Womens Hosp, Dept Radiol, Boston, MA 02115 USA
关键词
D O I
10.1097/01.RVI.0000231966.74734.7D
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
Translumbar embolization of type II endoleaks after endovascular abdominal aneurysm repair has been proved to be effective. One challenge of this approach is the choice of the most suitable image guiding modality. For needle placement, cross-sectional imaging under computed tomographic (CT) guidance is preferable. For embolization, fluoroscopy is the modality of choice for most interventionalists. A new technology can acquire CT-like images by rotating an angiographic, flat-panel detector of a C-arm around the patient. This technology allows a combination of fluoroscopic and CT guidance within the angiographic suite. The authors describe the successful use of a combination of fluoroscopy and angiographic CT in three cases of translumbar type II endoleak embolization.
引用
收藏
页码:1349 / 1353
页数:5
相关论文
共 15 条
[1]
Diagnosis and treatment of inferior mesenteric arterial endoleaks after endovascular repair of abdominal aortic aneurysms [J].
Baum, RA ;
Carpenter, JP ;
Tuite, CM ;
Velazquez, OC ;
Soulen, MC ;
Barker, CF ;
Golden, MA ;
Pyeron, AM ;
Fairman, RM .
RADIOLOGY, 2000, 215 (02) :409-413
[2]
Endoleaks after endovascular repair of abdominal aortic aneurysms [J].
Baum, RA ;
Stavropoulos, SW ;
Fairman, RM ;
Carpenter, JP .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2003, 14 (09) :1111-1117
[3]
Treatment of type 2 endoleaks after endovascular repair of abdominal aortic aneurysms: Comparison of transarterial and translumbar techniques - Discussion [J].
Freischlag, JA ;
Baum, RA ;
Brewster, DC ;
Zarins, CK .
JOURNAL OF VASCULAR SURGERY, 2002, 35 (01) :29-29
[4]
Translumbar embolization of type 2 endoleaks after endovascular repair of abdominal aortic aneurysms [J].
Baum, RA ;
Cope, C ;
Fairman, RM ;
Carpenter, JP .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2001, 12 (01) :111-116
[5]
Outcomes of secondary interventions after abdominal aortic aneurysm endovascular repair [J].
Becquemin, JP ;
Kelley, L ;
Zubilewicz, T ;
Desgranges, P ;
Lapeyre, M ;
Kobeiter, H .
JOURNAL OF VASCULAR SURGERY, 2004, 39 (02) :298-304
[6]
Ultrasound-guided percutaneous transabdominal treatment of a type 2 endoleak [J].
Boks, SS ;
Andhyiswara, T ;
de Smet, AAEA ;
Vroegindeweij, D .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2005, 28 (04) :526-529
[7]
Giant gastroduodenal artery pseudoaneurysm due to polyarteritis noclosa as a cause of obstructive jaundice: Imaging findings and coil embolization results [J].
Ellis, PK ;
Kennedy, PT ;
Collins, AJ .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2005, 28 (06) :854-854
[8]
Combined laparoscopic and percutaneous treatment of a type II endoleak following endovascular abdominal aortic aneurysm repair [J].
Karkos, CD ;
Hayes, PD ;
Lloyd, DM ;
Fishwick, G ;
White, SA ;
Quadar, S ;
Sayers, RD .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2005, 28 (05) :656-660
[9]
Percutaneous ultrasound-guided thrombin injection for endoleaks: An alternative [J].
Kasthuri, RS ;
Stivaros, SM ;
Gavan, D .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2005, 28 (01) :110-112
[10]
Successful treatment of a type-II endoleak with percutaneous CT-guided thrombin injection in a patient after endovascular abdominal aortic aneurysm repair [J].
Krueger, K ;
Zaehringer, M ;
Gawenda, M ;
Brunkwall, J ;
Lackner, K .
EUROPEAN RADIOLOGY, 2003, 13 (07) :1748-1749