An unbiased parametric imaging algorithm for nonuniformly sampled biomedical system parameter estimation

被引:78
作者
Feng, DG
Huang, SC
Wang, ZZ
机构
[1] UNIV CALIF LOS ANGELES,SCH MED,DEPT MOL & MED PHARMACOL,DIV NUCL MED & BIOPHYS,LOS ANGELES,CA 90024
[2] UNIV CALIF LOS ANGELES,SCH MED,DEPT BIOMATH,LOS ANGELES,CA 90024
基金
澳大利亚研究理事会;
关键词
D O I
10.1109/42.511754
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
An unbiased algorithm of generalized linear least squares (GLLS) for parameter estimation of nonuniformly sampled biomedical systems is proposed. The basic theory and detailed derivation of the algorithm are given, This algorithm removes the initial values required and computational burden of nonlinear least regression and achieves a comparable estimation quality in terms of the estimates' bias and standard deviation, Therefore, this algorithm is particular useful in image-wide (pixel-by-pixel based) parameter estimation, e.g., to generate parametric images from tracer dynamic studies with positron emission tomography. An example is presented to demonstrate the performance of this new technique. This algorithm is also generally applicable to other continuous system parameter estimation.
引用
收藏
页码:512 / 518
页数:7
相关论文
共 28 条
[1]   STRATEGY FOR THE MEASUREMENT OF REGIONAL CEREBRAL BLOOD-FLOW USING SHORT-LIVED TRACERS AND EMISSION TOMOGRAPHY [J].
ALPERT, NM ;
ERIKSSON, L ;
CHANG, JY ;
BERGSTROM, M ;
LITTON, JE ;
CORREIA, JA ;
BOHM, C ;
ACKERMAN, RH ;
TAVERAS, JM .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1984, 4 (01) :28-34
[3]   WEIGHTED INTEGRATION METHOD FOR LOCAL CEREBRAL BLOOD-FLOW MEASUREMENTS WITH POSITRON EMISSION TOMOGRAPHY [J].
CARSON, RE ;
HUANG, SC ;
GREEN, MV .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1986, 6 (02) :245-258
[4]  
CHEN K, 1981, J NUCL MED, V32, P1003
[5]  
DARGENIO DZ, 1990, ADAPT 2 USERS GUIDE
[6]  
EVANS AC, 1987, J CEREB BLOOD FLO S1, V7, pS453
[7]   MODELS FOR COMPUTER-SIMULATION STUDIES OF INPUT FUNCTIONS FOR TRACER KINETIC MODELING WITH POSITRON EMISSION TOMOGRAPHY [J].
FENG, D ;
HUANG, SC ;
WANG, XM .
INTERNATIONAL JOURNAL OF BIO-MEDICAL COMPUTING, 1993, 32 (02) :95-110
[8]  
Feng D., 1993, ANN NUCL MED, V7, pS33
[9]   A STUDY ON STATISTICALLY RELIABLE AND COMPUTATIONALLY EFFICIENT ALGORITHMS FOR GENERATING LOCAL CEREBRAL BLOOD-FLOW PARAMETRIC IMAGES WITH POSITRON EMISSION TOMOGRAPHY [J].
FENG, DG ;
WANG, ZZ ;
HUANG, SC .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1993, 12 (02) :182-188
[10]  
GINSBERG MD, 1982, ANN NEUROL, V15, P812