A tapered titanium femoral stem inserted without cement in a total hip arthroplasty - Radiographic evaluation and stability

被引:85
作者
Mulliken, BD
Bourne, RB
Rorabeck, CH
Nayak, N
机构
[1] UNIV WESTERN ONTARIO HOSP, DIV ORTHOPAED SURG, LONDON, ON N6A 5A5, CANADA
[2] PIERSON CLIN BLDG, Grosse Pointe Farms, MI 48236 USA
关键词
D O I
10.2106/00004623-199608000-00012
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The results of 416 total hip arthroplasties performed in 372 patients with insertion of a Mallory-Head titanium femoral component without cement were reviewed retrospectively, to determine the stability and the radiographic parameters of stability for this type of stein, The average duration of clinical and radiographic follow-up was 3.7 years (range, 2.0 to 6.5 years), No revisions were performed to treat instability of the stem, pain, or osteolysis by the time of the latest follow-up examination Although the clinical results were excellent, the radiographic signs of fixation that have been well described for chromium-cobalt sterns were frequently absent, So-called endosteal spot welds, commonly seen in association, with long, extensively coated stems, were seen. infrequently, Resorptive bone-remodeling rarely extended beyond zones 1 and 7 of Gruen et al, Both endosteal and periosteal distal cortical hypertrophy was common, but the cause was unknown. Osteolysis of the distal aspect of the femur, shedding of the porous coating, and breakage of the stem mere not seen, Forty-four sterns (11 per cent) had initial subsidence; however, it nearly always stabilized within six months postoperatively and did not affect the eventual stability at the time of the short-term follow-up, The short-term clinical outcome confirmed the stability of these stems that had been determined from the radiographic findings and the lack of revisions, At the latest follow-up examination, 323 (87 per cent) of the patients (362 [87 per cent] of the hips) had no or slight pain in the lower limb over-all and only twenty-two (6 percent) of the patients (twenty-seven [6 per rent] of the hips) had pain in the thigh, This tapered titanium femoral component appears to provide excellent short-term stability without resorptive bone-remodeling, osteolysis, or a high prevalence of pain in the thigh, Radiographic evaluation of stability of this stem is clearly different from that of chromium-cobalt stems - particularly extensively coated anatomic medullary locking stems - in that so-called spot welds and severe resorptive bone changes were uncommon and distal cortical hypertrophy was common.
引用
收藏
页码:1214 / 1225
页数:12
相关论文
共 78 条
[1]
METALLIC WEAR IN FAILED TITANIUM-ALLOY TOTAL HIP REPLACEMENTS - A HISTOLOGICAL AND QUANTITATIVE-ANALYSIS [J].
AGINS, HJ ;
ALCOCK, NW ;
BANSAL, M ;
SALVATI, EA ;
WILSON, PD ;
PELLICCI, PM ;
BULLOUGH, PG .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (03) :347-356
[2]
[Anonymous], 1979, CLIN ORTHOP RELAT RE
[3]
BOBYN JD, 1992, CLIN ORTHOP RELAT R, P79
[4]
BOBYN JD, 1990, CLIN ORTHOP RELAT R, V261, P196
[5]
BOURNE RB, 1994, CLIN ORTHOP RELAT R, V298, P37
[6]
BURKART BC, 1993, ORTHOP CLIN N AM, V24, P645
[7]
THE EFFECT OF FEMORAL STEM GEOMETRY ON INTERFACE MOTION IN UNCEMENTED POROUS-COATED TOTAL HIP PROSTHESES - COMPARISON OF STRAIGHT-STEM AND CURVED-STEM DESIGNS [J].
CALLAGHAN, JJ ;
FULGHUM, CS ;
GLISSON, RR ;
STRANNE, SK .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (06) :839-848
[8]
THE UNCEMENTED POROUS-COATED ANATOMIC TOTAL HIP-PROSTHESIS - 2-YEAR RESULTS OF A PROSPECTIVE CONSECUTIVE SERIES [J].
CALLAGHAN, JJ ;
DYSART, SH ;
SAVORY, CG .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (03) :337-346
[9]
THE CLINICAL-RESULTS AND BASIC SCIENCE OF TOTAL HIP-ARTHROPLASTY WITH POROUS-COATED PROSTHESES [J].
CALLAGHAN, JJ .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1993, 75A (02) :299-310
[10]
ASSESSING THE RESULTS OF HIP-REPLACEMENT - A COMPARISON OF 5 DIFFERENT RATING SYSTEMS [J].
CALLAGHAN, JJ ;
DYSART, SH ;
SAVORY, CF ;
HOPKINSON, WJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1990, 72 (06) :1008-1009