Angiographic computed tomography is comparable to multislice computed tomography in lumbar myelographic imaging

被引:9
作者
Buhk, Jan-Hendrik [1 ]
Elof, Erck [1 ]
Knauth, Michael [1 ]
机构
[1] Univ Gottingen, Dept Neuroradiol, D-37075 Gottingen, Germany
关键词
spine; myelography; computed tomography; rotational angiography; angiographic ct; myelographic ct; flat panel;
D O I
10.1097/01.rct.0000228152.73528.54
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We evaluated the feasibility of angiographic computed tomography (ACT) for diagnostic imaging in a patient with degenerative lumbar spine disease. ACT provides a volume data set out of a rotational acquisition with a c-arm-mounted flat-panel detector. Using this technique, radiographic myelography and myelographic computed tomography can be performed in a single session at the same imaging system. The quality of the reconstructed ACT slice images is comparable to those acquired by postmyelographic computed tomography.
引用
收藏
页码:739 / 741
页数:3
相关论文
共 11 条
  • [1] Randomized study of the safety and clinical utility of rotational vs. standard coronary angiography using a flat-panel detector
    Akhtar, M
    Vakharia, KT
    Mishell, J
    Gera, A
    Ports, TA
    Yeghiazarians, Y
    Michaels, AD
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2005, 66 (01) : 43 - 49
  • [2] A COMPARISON OF COMPUTED TOMOGRAPHY-MYELOGRAPHY, MAGNETIC-RESONANCE-IMAGING, AND MYELOGRAPHY IN THE DIAGNOSIS OF HERNIATED NUCLEUS PULPOSUS AND SPINAL STENOSIS
    BISCHOFF, RJ
    RODRIGUEZ, RP
    GUPTA, K
    RIGHI, A
    DALTON, JE
    WHITECLOUD, TS
    [J]. JOURNAL OF SPINAL DISORDERS, 1993, 6 (04): : 289 - 295
  • [3] Kalender WA, 2003, RADIOLOGE, V43, P379, DOI 10.1007/s00117-003-0897-4
  • [4] Kufeld M, 2003, AM J NEURORADIOL, V24, P1290
  • [5] Loose R., 2005, ROFO, VS1, pPO160
  • [6] Saint-Louis LA, 2001, CLIN ORTHOP RELAT R, P122
  • [7] Schueler BA, 2005, AM J NEURORADIOL, V26, P1898
  • [8] SCHUMACHER M, 1989, AM J NEURORADIOL, V10, P644
  • [9] Radiation dose to patients and radiologists during transcatheter arterial embolization: Comparison of a digital flat-panel system and conventional unit
    Suzuki, S
    Furui, S
    Kobayashi, I
    Yamauchi, T
    Kohtake, H
    Takeshita, K
    Takada, K
    Yamagishi, M
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 185 (04) : 855 - 859
  • [10] Application of multi-detector row helical scanning to postmyelographic CT
    Tsuchiya, K
    Katase, S
    Aoki, C
    Hachiya, J
    [J]. EUROPEAN RADIOLOGY, 2003, 13 (06) : 1438 - 1443