Fast determination of paracetamol by using a very simple photometric flow-through sensing device

被引:63
作者
Cañada, MJA [1 ]
Reguera, MIP [1 ]
Medina, AR [1 ]
de Córdova, MLF [1 ]
Díaz, AM [1 ]
机构
[1] Univ Jaen, Dept Phys & Analyt Chem, Fac Expt Sci, E-23071 Jaen, Spain
关键词
paracetamol; solid phase spectroscopy-FIA; flow-through optosensor; pharmaceuticals;
D O I
10.1016/S0731-7085(99)00265-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple flow-through UV optosensing device was developed:for the determination of paracetamol based on its transient retention and concentration on a suitable active solid support (Sephadex QAE A-25 anion-exchange resin) packed in the flow cell and the continuous monitoring of its native absorbance on the solid phase at 264 nm. The sample was injected into a 0.08-M NaCl carrier stream at pH 11.0 by using a simple monochannel FIA manifold. After developing the analytical signal, paracetamol was desorbed from the solid support by the carrier solution itself. A very good linear response was found in the concentration range 0.5-8.0 mu g ml(-1) with a RSD (%) of 1.24, a detection limit of 0.022 mu g ml(-1) and a sampling rate of 40 h(-1). A strong increase in sensitivity as well as a very much higher selectivity were achieved as compared with the conventional flow injection method as a consequence of the separation of the analyte from the sample plug and its retention on the active solid support placed in the detection area. Applicability of the proposed sensor to direct determination of paracetamol in pharmaceuticals (to solve the sample being the only treatment) was successfully demonstrated. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:59 / 66
页数:8
相关论文
共 19 条
[1]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF ACETAMINOPHEN IN PLASMA - SINGLE-DOSE PHARMACOKINETIC STUDIES [J].
AMEER, B ;
GREENBLATT, DJ ;
DIVOLL, M ;
ABERNETHY, DR ;
SHARGEL, L .
JOURNAL OF CHROMATOGRAPHY, 1981, 226 (01) :224-230
[2]  
Argekar A.P, 1997, INDIAN DRUGS, V34, P437
[3]   A selective optosensor for UV spectrophotometric determination of thiamine in the presence of other vitamins B [J].
Barrales, PO ;
de Córdova, MLF ;
Díaz, AM .
ANALYTICA CHIMICA ACTA, 1998, 376 (02) :227-233
[4]  
Cañada MJA, 1999, FRESEN J ANAL CHEM, V363, P59
[5]  
de Córdova MLF, 1998, ANAL CHIM ACTA, V369, P263
[6]  
ELOBEID HA, 1987, ANAL PROFILES DRUG S, V14, P567
[7]   A VALIDATED HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD FOR THE DETERMINATION OF PARACETAMOL AND ITS MAJOR METABOLITES IN URINE [J].
GOICOECHEA, AG ;
DEALDA, MJL ;
VILAJATO, JL .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1995, 18 (16) :3257-3268
[8]  
HASSAN SM, 1981, J ASSOC OFF ANA CHEM, V64, P1442
[9]   Simultaneous assay of phenylpropanolamine hydrochloride, caffeine, paracetamol, glycerylguaiacolate and chlorpheniramine maleate in Silabat(TM) tablet using HPLC with diode array detection [J].
Indrayanto, G ;
Sunarto, A ;
Adriani, Y .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1995, 13 (12) :1555-1559
[10]   Flow-through solid phase UV spectrophotometric determination of amoxycillin [J].
Medina, AR ;
de Córdova, MLF ;
Díaz, AM .
ANALYTICAL LETTERS, 1999, 32 (04) :729-742