The dynamic neutralization system for the spine: a multi-center study of a novel non-fusion system

被引:261
作者
Stoll, TM
Dubois, G
Schwarzenbach, O
机构
[1] Bethesda Spital, Dept Spinal Surg, CH-4020 Basel, Switzerland
[2] Nouvelle Clin Union, St Jean, France
[3] Spital Thun Simmental, Thun, Switzerland
关键词
lumbar spine; surgical treatment; non-fusion; instrumentation; instability;
D O I
10.1007/s00586-002-0438-2
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Various forms of lumbar instability require a surgical stabilization. As an alternative to fusion, a mobile, dynamic stabilization restricting segmental motion would be advantageous in various indications, allowing greater physiological function and reducing the inherent disadvantages of rigid instrumentation and fusion. The dynamic neutralization system for the spine (Dynesys) is a pedicle screw system for mobile stabilization, consisting of titanium alloy screws connected by an elastic synthetic compound, controlling motion in any plane (non-fusion system). This prospective, multi-center study evaluated the safety and efficacy of Dynesys in the treatment of lumbar instability conditions, evaluating pre- and postoperative pain, function, and radiological data on a consecutive series of 83 patients. Indications consisted of unstable segmental conditions, mainly combined with spinal stenosis (60.2%) and with degenerative discopathy (24.1%), in some cases with disc herniation (8.4%), and with revision surgery (6.0%). Thirty-nine patients additionally had degenerative spondylolisthesis, and 30 patients had undergone previous lumbar surgery. In 56 patients instrumentation was combined with direct decompression. The mean age at operation was 58.2 (range 26.8-85.3) years; the mean follow-up time was 38.1 months (range 11.2-79.1 months). There were nine complications unrelated to the implant, and one due to a screw malplacement. Four of them required an early surgical reintervention. Additional lumbar surgery in the follow-up period included: implant removal and conversion into spinal fusion with rigid instrumentation for persisting pain in three cases, laminectomy of an index segment in one case and screw removal due to loosening in one case. In seven cases, radiological signs of screw loosening were observed. In seven cases, adjacent segment degeneration necessitated further surgery. Mean pain and function scores improved significantly from baseline to follow-up, as follows: back pain scale from 7.4 to 3.1, leg pain scale from 6.9 to 2.4, and Oswestry Disability Index from 55.4% to 22.9%. These study results compare well with those obtained by conventional procedures; in addition to which, mobile stabilization is less invasive than fusion. Long-term screw fixation is dependent on correct screw dimension and proper screw positioning. The natural course of poly-segmental disease in some cases necessitates further surgery as the disease progresses. Dynamic neutralization proved to be a safe and effective alternative in the treatment of unstable lumbar conditions.
引用
收藏
页码:S170 / S178
页数:9
相关论文
共 44 条
[1]   BIOMECHANICAL EVALUATION OF LUMBAR SPINAL STABILITY AFTER GRADED FACETECTOMIES [J].
ABUMI, K ;
PANJABI, MM ;
KRAMER, KM ;
DURANCEAU, J ;
OXLAND, T ;
CRISCO, JJ .
SPINE, 1990, 15 (11) :1142-1147
[2]   Comparative results between conventional and computer-assisted pedicle screw installation in the thoracic, lumbar, and sacral spine [J].
Amiot, LP ;
Lang, K ;
Putzier, M ;
Zippel, H ;
Labelle, H .
SPINE, 2000, 25 (05) :606-614
[3]   Lumbar spinal stenosis:: Conservative or surgical management?: A prospective 10-year study [J].
Amundsen, T ;
Weber, H ;
Nordal, HJ ;
Magnaes, B ;
Abdelnoor, M ;
Lilleås, F .
SPINE, 2000, 25 (11) :1424-1435
[4]  
[Anonymous], 1992, Rachis
[5]   POSTFUSION INSTABILITY AT THE ADJACENT SEGMENTS AFTER RIGID PEDICLE SCREW FIXATION FOR DEGENERATIVE LUMBAR SPINAL-DISORDERS [J].
AOTA, Y ;
KUMANO, K ;
HIRABAYASHI, S .
JOURNAL OF SPINAL DISORDERS, 1995, 8 (06) :464-473
[6]   INCREASE OF MOTION BETWEEN LUMBAR VERTEBRAE AFTER EXCISION OF THE CAPSULE AND CARTILAGE OF THE FACETS - A CADAVER STUDY [J].
BODEN, SD ;
MARTIN, C ;
RUDOLPH, R ;
KIRKPATRICK, JS ;
MOEINI, SMR ;
HUTTON, WC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1994, 76A (12) :1847-1853
[7]   Surgical results after soft system stabilization of the lumbar spine in degenerative disc disease - Long term results [J].
Brechbuhler, D ;
Markwalder, TM ;
Braun, M .
ACTA NEUROCHIRURGICA, 1998, 140 (06) :521-525
[8]   THE ROLE OF FUSION AND INSTRUMENTATION IN THE TREATMENT OF DEGENERATIVE SPONDYLOLISTHESIS WITH SPINAL STENOSIS [J].
BRIDWELL, KH ;
SEDGEWICK, TA ;
OBRIEN, MF ;
LENKE, LG ;
BALDUS, C .
JOURNAL OF SPINAL DISORDERS, 1993, 6 (06) :461-472
[9]  
Dubois G., 1999, Lumbar segmental instability, P233
[10]   COMPLICATIONS ASSOCIATED WITH THE TECHNIQUE OF PEDICLE SCREW FIXATION - A SELECTED SURVEY OF ABS MEMBERS [J].
ESSES, SI ;
SACHS, BL ;
DREYZIN, V .
SPINE, 1993, 18 (15) :2231-2239