Single reading with computer-aided detection and double reading of screening mammograms in the United Kingdom national breast screening program

被引:66
作者
Gilbert, Fiona J.
Astley, Susan M.
McGee, Magnus A.
Gillan, Maureen G. C.
Boggis, Caroline R. M.
Griffiths, Pamela M.
Duffy, Stephen W.
机构
[1] Univ Aberdeen, Dept Radiol, Aberdeen AB25 2ZD, Scotland
[2] Univ Manchester, Dept Imaging Sci & Biomed Engn, Manchester, Lancs, England
[3] Christchurch Sch Med, Dept Publ Hlth & Gen Practice, Christchurch, New Zealand
[4] Withington Hosp, Nightingale Ctr, Manchester M20 8LR, Lancs, England
[5] Wolfson Inst Prevent Med, Dept Epidemiol Math & Stat, London, England
关键词
D O I
10.1148/radiol.2411051092
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To retrospectively determine if the use of a computer-aided detection ( CAD) system can improve the performance of single reading of screening mammograms to match that of double reading in the United Kingdom. Materials and Methods: Local research ethics committee approval was obtained; informed consent was not required. This study included a sample of 10 267 mammograms obtained in women aged 50 years or older who underwent routine screening at one of two breast screening centers in 1996. Mammograms that were double read in 1996 were randomly allocated to be re-read by eight different radiologists using CAD. The cancer detection and recall rates from double reading and single reading with CAD were compared. Statistical significance and confidence intervals were calculated with the McNemar test to account for the matched nature of the data. Results: Single reading with CAD led to a cancer detection rate that was significantly (P = .02) higher than that achieved with double reading: 6.5% more cancers were detected by means of single reading with CAD than by means of double reading. However, the recall rate was higher for single reading with CAD than for double reading (8.6% vs 6.5%, respectively; P < .001). This was equivalent to relative increases of 15% and 32% in the cancer detection and recall rates, respectively. Conclusion: Single reading with CAD leads to an improved cancer detection rate and an increased recall rate.
引用
收藏
页码:47 / 53
页数:7
相关论文
共 34 条
[1]   DOUBLE READING OF MAMMOGRAPHY SCREENING FILMS - ONE RADIOLOGIST OR 2 [J].
ANTTINEN, I ;
PAMILO, M ;
SOIVA, M ;
ROIHA, M .
CLINICAL RADIOLOGY, 1993, 48 (06) :414-421
[2]  
ASTLEY S, 2004, P 7 INT WORKSH DIG M
[3]   Mammographic characteristics of 115 missed cancers later detected with screening mammography and the potential utility of computer-aided detection [J].
Birdwell, RL ;
Ikeda, DM ;
O'Shaughnessy, KF ;
Sickles, EA .
RADIOLOGY, 2001, 219 (01) :192-202
[4]   The effect of changing from one to two views at incident (subsequent) screens in the NHS breast screening programme in England: impact on cancer detection and recall rates [J].
Blanks, RG ;
Bennett, RL ;
Patnick, J ;
Cush, S ;
Davison, C ;
Moss, SM .
CLINICAL RADIOLOGY, 2005, 60 (06) :674-680
[5]   A comparison of cancer detection rates achieved by breast cancer screening programmes by number of readers, for one and two view mammography: results from the UK National Health Service breast screening programme [J].
Blanks, RG ;
Wallis, MG ;
Moss, SM .
JOURNAL OF MEDICAL SCREENING, 1998, 5 (04) :195-201
[6]   Results from the UKNHS breast screening programme 1994-1999 [J].
Blanks, RG ;
Moss, SM ;
Patnick, J .
JOURNAL OF MEDICAL SCREENING, 2000, 7 (04) :195-198
[7]   Computer-assisted mammographic imaging [J].
Boggis, CR ;
Astley, SM .
BREAST CANCER RESEARCH, 2000, 2 (06) :392-395
[8]   Improvement in sensitivity of screening mammography with computer-aided detection: A multiinstitutional trial [J].
Brem, RF ;
Baum, J ;
Lechner, M ;
Kaplan, S ;
Souders, S ;
Naul, LG ;
Hoffmeister, J .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 181 (03) :687-693
[9]  
Burhenne LJW, 2000, RADIOLOGY, V215, P554
[10]   Comparison of standard reading and computer aided detection (CAD) on a national proficiency test of screening mammography [J].
Ciatto, S ;
Del Turco, MR ;
Risso, G ;
Catarzi, S ;
Bonardi, R ;
Viterbo, V ;
Gnutti, P ;
Guglielmoni, B ;
Pinelli, L ;
Pandiscia, A ;
Navarra, F ;
Lauria, A ;
Palmiero, R ;
Indovina, PL .