Novel potentiometric and optical silver ion-selective sensors with subnanomolar detection limits

被引:89
作者
Szigeti, Zsofia
Malon, Adam
Vigassy, Tamas
Csokai, Viktor
Grun, Alajos
Wygladacz, Katarzyna
Ye, Nan
Xu, Chao
Chebny, Vincent J.
Bitter, Istvan
Rathore, Rajendra
Bakker, Eric
Pretsch, Erno
机构
[1] Marquette Univ, Dept Chem, Milwaukee, WI 53210 USA
[2] ETH, Organ Chem Lab, CH-8093 Zurich, Switzerland
[3] Budapest Univ Technol & Econ, Dept Organ Chem Technol, H-1521 Budapest, Hungary
[4] Purdue Univ, Dept Chem, W Lafayette, IN 47907 USA
关键词
ion-selective electrodes; fluorescent microspheres; silver sensors; complex formation constants; lower detection limit; long-term stability;
D O I
10.1016/j.aca.2006.05.009
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Ten Ag+-selective ionophores have been characterized in terms of their potentiometric selectivities and complex formation constants in solvent polymeric membranes. The compounds with pi-coordination show much weaker interactions than those with thioether or thiocarbarnate groups as the coordinating sites. Long-term studies with the best ionophores show that the lower detection limit of the best Ag+ sensors can be maintained in the subnanomolar range for at least 1 month. The best ionophores have also been characterized in fluorescent microspheres. The so far best lower detection limits of 3 x 10(-11) M (potentiometrically) and 2 x 10(-11) M Ag+ (optically) are found with bridged thiacalixarenes. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 10
页数:10
相关论文
共 57 条
[1]  
[Anonymous], 1976, PURE APPL CHEM, V48, P127, DOI DOI 10.1351/PAC197648010127
[2]   A new neutral carrier for silver ions based on a bis(thiothiazole) derivative and its evaluation in membrane electrodes [J].
Badr, IHA .
MICROCHIMICA ACTA, 2005, 149 (1-2) :87-94
[3]   Determination of unbiased selectivity coefficients of neutral carrier-based cation-selective electrodes [J].
Bakker, E .
ANALYTICAL CHEMISTRY, 1997, 69 (06) :1061-1069
[4]   Ion-selective electrodes based on two competitive ionophores for determining effective stability constants of ion-carrier complexes in solvent polymer membranes [J].
Bakker, E ;
Pretsch, E .
ANALYTICAL CHEMISTRY, 1998, 70 (02) :295-302
[5]   DETERMINATION OF COMPLEX-FORMATION CONSTANTS OF NEUTRAL CATION-SELECTIVE IONOPHORES IN SOLVENT POLYMERIC MEMBRANES [J].
BAKKER, E ;
WILLER, M ;
LERCHI, M ;
SEILER, K ;
PRETSCH, E .
ANALYTICAL CHEMISTRY, 1994, 66 (04) :516-521
[6]  
Bakker E, 1999, ELECTROANAL, V11, P915, DOI 10.1002/(SICI)1521-4109(199909)11:13<915::AID-ELAN915>3.0.CO
[7]  
2-J
[8]   Selectivity of potentiometric ion sensors [J].
Bakker, E ;
Pretsch, E ;
Bühlmann, P .
ANALYTICAL CHEMISTRY, 2000, 72 (06) :1127-1133
[9]   Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics [J].
Bakker, E ;
Buhlmann, P ;
Pretsch, E .
CHEMICAL REVIEWS, 1997, 97 (08) :3083-3132
[10]   AN EASY ACCESS TO TETRA-O-ALKYLATED CALIX[4]ARENES OF CONE CONFORMATION [J].
BITTER, I ;
GRUN, A ;
AGAI, B ;
TOKE, L .
TETRAHEDRON, 1995, 51 (28) :7835-7840