Amperometric enzyme electrodes for aerobic and anaerobic glucose monitoring prepared by glucose oxidase immobilized in mixed ferrocene-cobaltocenium dendrimers

被引:71
作者
Alonso, B [1 ]
Armada, PG
Losada, J
Cuadrado, I
González, B
Casado, CM
机构
[1] Univ Autonoma Madrid, Fac Ciencias, Dept Quim Inorgan, E-28049 Madrid, Spain
[2] Univ Politecn Madrid, Escuela Tecn Super Ingn Ind, Dept Ingn Quim Ind, E-28006 Madrid, Spain
关键词
enzyme sensor; glucose; modified electrode; ferrocene; cobaltocenium; dendrimer;
D O I
10.1016/j.bios.2003.12.024
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The enzyme glucose oxidase (GOx) has been immobilized electrostatically onto carbon and platinum electrodes modified with mixed ferrocene-cobaltocenium dendrimers. The ferrocene units have been used successfully as mediators between the GOx and the electrode under anaerobic conditions. In experiments carried out in the presence of oxygen, the cobaltocenium moieties act as electrocatalysts in the reduction of the oxygen in the solution, thus making possible the determination of the oxygen variation due to the enzymatic reaction, with high sensitivity. The current response of the electrode was determined by measuring steady-state current values obtained applying a constant potential. The effect of the substrate concentration, the dendrimer generation, the thickness of the dendrimer layer, interferences, and storage on the response of the sensors were investigated. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:1617 / 1625
页数:9
相关论文
共 34 条
[1]   ELECTRODES MODIFIED WITH ELECTROACTIVE FILMS OF ORGANOMETALLIC DENDRIMERS [J].
ALONSO, B ;
MORAN, M ;
CASADO, CM ;
LOBETE, F ;
LOSADA, J ;
CUADRADO, I .
CHEMISTRY OF MATERIALS, 1995, 7 (08) :1440-1442
[2]   ELECTROCATALYTIC REDUCTION OF CO2 AND O-2 WITH ELECTROPOLYMERIZED FILMS OF VINYL-TERPYRIDINE COMPLEXES OF FE, NI AND CO [J].
ARANA, C ;
KESHAVARZ, M ;
POTTS, KT ;
ABRUNA, HD .
INORGANICA CHIMICA ACTA, 1994, 225 (1-2) :285-295
[3]  
Armada MPG, 2003, SENSOR ACTUAT B-CHEM, V88, P190, DOI 10.1016/S0925-4005(02)00326-X
[4]   THIN-FILM BIENZYME AMPEROMETRIC BIOSENSORS BASED ON POLYMERIC REDOX MEDIATORS WITH ELECTROSTATIC BIPOLAR PROTECTING LAYER [J].
BOGUSLAVSKY, L ;
KALASH, H ;
XU, Z ;
BECKLES, D ;
GENG, L ;
SKOTHEIM, T ;
LAURINAVICIUS, V ;
LEE, HS .
ANALYTICA CHIMICA ACTA, 1995, 311 (01) :15-21
[5]   Redox-active ferrocenyl dendrimers and polymers in solution and immobilised on electrode surfaces [J].
Casado, CM ;
Cuadrado, I ;
Morán, M ;
Alonso, B ;
García, B ;
González, B ;
Losada, J .
COORDINATION CHEMISTRY REVIEWS, 1999, 185-6 :53-79
[6]  
Casado CM, 2000, ANGEW CHEM INT EDIT, V39, P2135, DOI 10.1002/1521-3773(20000616)39:12<2135::AID-ANIE2135>3.3.CO
[7]  
2-I
[8]   POLYMERIC REDOX MEDIATOR ENZYME ELECTRODES FOR ANAEROBIC GLUCOSE MONITORING [J].
CHEN, CJ ;
LIU, CC ;
SAVINELL, RF .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1993, 348 (1-2) :317-338
[9]   Organometallic dendrimers with transition metals [J].
Cuadrado, I ;
Morán, M ;
Casado, CM ;
Alonso, B ;
Losada, J .
COORDINATION CHEMISTRY REVIEWS, 1999, 193-5 :395-445
[10]   A SIMPLE METHOD FOR CATALYST IMMOBILIZATION ON ELECTRODE SURFACES [J].
DESMET, S ;
CASSIDY, J ;
MCCORMAC, T ;
MAES, NA .
ELECTROANALYSIS, 1995, 7 (08) :782-784