Estimating Activity-related Energy Expenditure Under Sedentary Conditions Using a Tri-axial Seismic Accelerometer

被引:56
作者
van Hees, Vincent T. [1 ,2 ]
van Lummel, Rob C. [2 ]
Westerterp, Klaas R. [1 ]
机构
[1] Maastricht Univ, Dept Human Biol, Maastricht, Netherlands
[2] McRoberts BV, The Hague, Netherlands
关键词
PHYSICAL-ACTIVITY ASSESSMENT; DOUBLY LABELED WATER; INTRAINDIVIDUAL VARIABILITY; ACTIVITY MONITORS; CHILDREN; ADOLESCENTS; CALIBRATION; PREDICTION; CHAMBER; OBESITY;
D O I
10.1038/oby.2009.55
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Activity-related energy expenditure (AEE) is difficult to quantify, especially under sedentary conditions. Here, a model was developed using the detected type of physical activity (PA) and movement intensity (MI), based on a tri-axial seismic accelerometer (DynaPort MiniMod; McRoberts B. V., The Hague, the Netherlands), with energy expenditure for PA as a reference. The relation between AEE (J/min/kg), MI, and the type of PA was determined for standardized PAs as performed in a laboratory including: lying, sitting, standing, and walking. AEE (J/min/kg) was calculated from total energy expenditure (TEE) and sleeping metabolic rate (SMR) as assessed with indirect calorimetry ((TEE x 0.9)-SMR). Subsequently, the model was validated over 23-h intervals in a respiration chamber. Subjects were 15 healthy women (age: 22 +/- 2 years; BMI: 24.0 +/- 4.0 kg/m(2)). Predicted AEE in the chamber was significantly related to measured AEE both within (r(2) = 0.81 +/- 0.06, P < 0.00001) and between (r(2) = 0.70, P < 0.001) subjects. The explained variation in AEE by the model was higher than the explained variation by MI alone. This shows that a tri-axial seismic accelerometer is a valid tool for estimating AEE under sedentary conditions.
引用
收藏
页码:1287 / 1292
页数:6
相关论文
共 37 条
  • [1] ADRIAENS MP, 2003, BR J NUTR
  • [2] BOUTEN CV, 1994, MED SCI SPORT EXER, V26, P1516
  • [3] BRAY MS, 1994, MED SCI SPORT EXER, V26, P1524
  • [4] Sitting time and work patterns as indicators of overweight and obesity in Australian adults
    Brown, WJ
    Miller, YD
    Miller, R
    [J]. INTERNATIONAL JOURNAL OF OBESITY, 2003, 27 (11) : 1340 - 1346
  • [5] Chen Kong Y, 2003, Diabetes Technol Ther, V5, P1023, DOI 10.1089/152091503322641088
  • [6] Efficiency of walking and stepping: Relationship to body fatness
    Chen, KY
    Acra, SA
    Donahue, CL
    Sun, M
    Buchowski, MS
    [J]. OBESITY RESEARCH, 2004, 12 (06): : 982 - 989
  • [7] Improving energy expenditure estimation by using a triaxial accelerometer
    Chen, KY
    Sun, M
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1997, 83 (06) : 2112 - 2122
  • [8] The technology of accelerometry-based activity monitors: Current and future
    Chen, KY
    Bassett, DR
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2005, 37 (11) : S490 - S500
  • [9] Accelerometers and pedometers: methodology and clinical application
    Corder, Kirsten
    Brage, Soren
    Ekelund, Ulf
    [J]. CURRENT OPINION IN CLINICAL NUTRITION AND METABOLIC CARE, 2007, 10 (05) : 597 - 603
  • [10] Validity of a multisensor armband in estimating 24-h energy expenditure in children
    Dorwny, Cindy A.
    Cho, Leena
    Akohoue, Sylvie A.
    Chen, Kong Y.
    Buchowski, Maciej S.
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2008, 40 (04) : 699 - 706