Coupling of capillary electrophoresis with ICP-MS for speciation investigations

被引:109
作者
Michalke, B
Schramel, P
机构
[1] GSF Research Centre for Environment and Health, Institute of Ecological Chemistry Neuherberg
来源
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY | 1997年 / 357卷 / 06期
关键词
D O I
10.1007/s002160050220
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An online hyphenation of capillary electrophoresis (CE) with inductively coupled plasma-mass spectrometry (ICP-MS) is developed, using a homemade nebulizer as the interface. The high resolution power of CE is used for the separation of metal species, whereas ICP-MS is taken for element specific detection with low detection limits. Metal species of standard solutions and real samples are separated and monitored by UV and ICP-MS. After optimization, electropherograms with high resolution were obtained, showing low detection limits around 1 mu g/L (e.g. Pt-species) and very high resolution. Typical analysis times were below 22 min. Quality control aspects concerned species stability during the analytical procedure and stability of electrical current during nebulization. A possible interfering suction flow was estimated and found to be negligible.
引用
收藏
页码:594 / 599
页数:6
相关论文
共 33 条
[1]  
BRO S, 1988, J TRACE ELEM ELECT H, V2, P165
[2]  
CARUSO JA, 1996, 26 INT S ENV AN CHEM
[3]   ISOELECTRIC-FOCUSING BY FREE SOLUTION CAPILLARY ELECTROPHORESIS [J].
CHEN, SM ;
WIKTOROWICZ, JE .
ANALYTICAL BIOCHEMISTRY, 1992, 206 (01) :84-90
[4]   CAPILLARY ZONE ELECTROPHORESIS - ITS APPLICABILITY AND POTENTIAL IN BIOCHEMICAL-ANALYSIS [J].
DEYL, Z ;
STRUZINSKY, R .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1991, 569 (1-2) :63-122
[5]  
DORNER K, 1990, J TRACE ELEM ELECT H, V4, P37
[6]   ANALYSIS OF PROTEIN-FRACTIONS BY MICROPREPARATIVE CAPILLARY ISOELECTRIC-FOCUSING AND MATRIX-ASSISTED LASER-DESORPTION TIME-OF-FLIGHT MASS-SPECTROMETRY [J].
FORET, F ;
MULLER, O ;
THORNE, J ;
GOTZINGER, W ;
KARGER, BL .
JOURNAL OF CHROMATOGRAPHY A, 1995, 716 (1-2) :157-166
[7]   SAMPLE SELF-STACKING IN ZONE ELECTROPHORESIS - THEORETICAL DESCRIPTION OF THE ZONE ELECTROPHORETIC SEPARATION OF MINOR COMPOUNDS IN THE PRESENCE OF BULK AMOUNTS OF A SAMPLE COMPONENT WITH HIGH MOBILITY AND LIKE CHARGE [J].
GEBAUER, P ;
THORMANN, W ;
BOCEK, P .
JOURNAL OF CHROMATOGRAPHY, 1992, 608 (1-2) :47-57
[8]  
GILON N, 1996, 4 INT S HYPH TECHN C
[9]   CAPILLARY ZONE ELECTROPHORESIS FOR THE RAPID SCREENING OF BANNED DRUGS IN SPORT [J].
GONZALEZ, E ;
LASERNA, JJ .
ELECTROPHORESIS, 1994, 15 (02) :240-243
[10]   HIGH-PERFORMANCE CAPILLARY ELECTROPHORESIS OF PROTEINS FROM THE FLUID LINING OF THE LUNGS OF RATS EXPOSED TO PERFLUOROISOBUTYLENE [J].
GURLEY, LR ;
BUCHANAN, JS ;
LONDON, JE ;
STAVERT, DM ;
LEHNERT, BE .
JOURNAL OF CHROMATOGRAPHY, 1991, 559 (1-2) :411-429