Fluorescein fluorescence hyperpolarization as an early kinetic measure of the apoptotic process

被引:24
作者
Zurgil, N [1 ]
Schiffer, Z [1 ]
Shafran, Y [1 ]
Kaufman, M [1 ]
Deutsch, M [1 ]
机构
[1] Bar Ilan Univ, Dept Phys, Jerome Schottenstein Cellscan Ctr Early Detect Ca, IL-52900 Ramat Gan, Israel
关键词
cellscan; apoptosis; fluorescence polarization; thymocytes;
D O I
10.1006/bbrc.1999.1934
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The ability to identify apoptotic cells within a complex population is crucial in the research and diagnosis of normal physiology and disease states. The Cellscan mark S (CS-S) cytometer was used in this study to detect intracellular fluorescence intensity and polarization (FI and FP) in several well-established models of apoptosis: Following spontaneous apoptosis, as well as glucocorticoid or anti Fas-induced apoptosis, CS-S individual cell-based analysis revealed the appearance of a cell cluster characterized by low FI and high FP. Temporal analysis of annexine V binding and FP measurements following DXM treatment showed that hyperpolarization preceded phosphatidylserine appearance on the outer plasma membrane. The early increase in FP was found to be dose dependent and inversely related to cell diameter. Cell dehydration and alteration of plasma membrane transport properties, both occurring during early stages of apoptosis, may be involved in the phenomena of intracellular fluorescein hyper-polarization in apoptosis. (C) 2000 Academic Press.
引用
收藏
页码:155 / 163
页数:9
相关论文
共 54 条
[1]  
Adayev T, 1998, J NEUROCHEM, V71, P1854
[2]  
Algeciras-Schimnich A, 1999, J IMMUNOL, V162, P5205
[3]  
BENDER E, 1999, CYTOMETRY, V35, P181
[4]   Anti-metatype antibody stabilization of Fv 4-4-20 variable domain dynamics [J].
Carrero, J ;
Mallender, WD ;
Voss, EW .
JOURNAL OF BIOLOGICAL CHEMISTRY, 1996, 271 (19) :11247-11252
[5]   FLUORESCEIN EXCITATION AND EMISSION POLARIZATION SPECTRA IN LIVING CELLS - CHANGES DURING CELL-CYCLE [J].
CERCEK, L ;
CERCEK, B ;
OCKEY, CH .
BIOPHYSICAL JOURNAL, 1978, 23 (03) :395-405
[6]   Flow cytometric ratio analysis of the Hoechst 33342 emission spectrum: Multiparametric characterization of apoptotic lymphocytes [J].
Chiu, L ;
Cherwinski, H ;
Ransom, J ;
Dunne, JF .
JOURNAL OF IMMUNOLOGICAL METHODS, 1996, 189 (02) :157-171
[7]  
COHEN JJ, 1993, IMMUNOL TODAY, V14, P126, DOI 10.1016/0167-5699(93)90214-6
[8]   LITHIUM INDUCES APOPTOSIS IN IMMATURE CEREBELLAR GRANULE CELLS BUT PROMOTES SURVIVAL OF MATURE NEURONS [J].
D'MELLO, SR ;
ANELLI, R ;
CALISSANO, P .
EXPERIMENTAL CELL RESEARCH, 1994, 211 (02) :332-338
[9]   FEATURES OF APOPTOTIC CELLS MEASURED BY FLOW-CYTOMETRY [J].
DARZYNKIEWICZ, Z ;
BRUNO, S ;
DELBINO, G ;
GORCZYCA, W ;
HOTZ, MA ;
LASSOTA, P ;
TRAGANOS, F .
CYTOMETRY, 1992, 13 (08) :795-808
[10]  
Darzynkiewicz Z, 1997, CYTOMETRY, V27, P1