Comparison of different analytical procedures in the determination of trace elements in lichens

被引:54
作者
Baffi, C
Bettinelli, M
Beone, GM
Spezia, S
机构
[1] Univ Cattolica Sacro Cuore, Ist Chim Agr & Ambientale, Fac Agr, I-29100 Piacenza, Italy
[2] ENEL, Prod Lab Piacenza, I-29100 Piacenza, Italy
关键词
trace elements; lichens; ICP-OES; ICP-MS; GFAAS; microwave digestion;
D O I
10.1016/S0045-6535(02)00094-2
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A BCR standard reference material of lichen (CRM 482) was used to validate an analytical procedure consisting of a microwave oven digestion associated with ICP-OES, ICP-MS and GFAAS techniques for the analysis of trace elements (Al, B, Ba, Cd, Co, Cr, Cu, Fe, Mn, Ni, Pb, Ti, V and Zn) in biomonitor samples. Two different acid mixtures were used: (a) 7 ml of HNO3, 1 ml of H2O2; (b) 7 ml of HNO3, 1 ml of H2O2 and 200 mul of HF; all digestions were carried out using 100-250 mg samples brought to a final volume of 50 ml. The validation of the procedure was carried out by two laboratories in terms of accuracy and precision; the former was estimated as percentage recovery by comparing experimental data with certificate values; the latter evaluated according to ISO standard 5725. Real lichen samples were analysed too with the procedures above described. In certified CRM 482 and real lichen samples the procedure with HF showed higher recovery values for Al, Ti, V, Ba and Fe than the procedure without HE. For all the other elements the two procedures gave comparable results both in terms of accuracy and precision. The recovery obtained with HF procedure for all the elements was generally better than 90-103%. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:299 / 306
页数:8
相关论文
共 10 条
[1]  
ASHLEY D, 1992, ATOM SPECTROSC, V13, P169
[2]   METAL BIOMONITORING WITH MOSSES - PROCEDURES FOR CORRECTING FOR SOIL CONTAMINATION [J].
BARGAGLI, R ;
BROWN, DH ;
NELLI, L .
ENVIRONMENTAL POLLUTION, 1995, 89 (02) :169-175
[3]  
Bettinelli M, 1996, ATOM SPECTROSC, V17, P133
[4]   THE USE OF MODIFIED MICROWAVE DIGESTION DISSOLUTION FOR THE QUANTITATIVE-DETERMINATION OF ALUMINUM, SILICON, AND IRON IN BIOLOGICAL-MATERIALS BY INDUCTIVELY-COUPLED PLASMA SPECTROMETRY [J].
FRIDLUND, S ;
LITTLEFIELD, S ;
RIVERS, J .
COMMUNICATIONS IN SOIL SCIENCE AND PLANT ANALYSIS, 1994, 25 (7-8) :933-941
[5]  
*ISO, 1989, ISO STAND HDB, V3
[6]  
LORENZINI G, 1999, PIANTE INQUINATMENTO, P247
[7]  
NIEBOER E, 1981, ATMOSPHERIC POLLUTAN, P339
[8]   Certified reference material of lichen (CRM 482) for the quality control of trace element biomonitoring [J].
Quevauviller, P ;
Herzig, R ;
Muntau, H .
SCIENCE OF THE TOTAL ENVIRONMENT, 1996, 187 (02) :143-152
[9]   INTERCOMPARISON TO IMPROVE THE QUALITY OF TRACE-ELEMENT DETERMINATION IN LICHENS [J].
QUEVAUVILLER, P ;
VANRENTERGHEM, D ;
MUNTAU, H ;
GRIEPINK, B .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1993, 53 (03) :233-242
[10]  
WYTTENBACH A, 1990, BIOL TRACE ELEMENT R, P213