A ZVZCS PWM FB DC/DC converter using a modified energy-recovery snubber

被引:80
作者
Kim, ES [1 ]
Kim, YH
机构
[1] Jeonju Univ, Dept Elect & Elect Engn, Jeonju 560759, South Korea
[2] Chung Ang Univ, Dept Elect Engn, Seoul 156756, South Korea
关键词
energy-recovery snubber; full-bridge (FB) dc/dc converter; small-signal modeling; zero-voltage switching (ZVS); zero-voltage zero-current switching (ZVZCS);
D O I
10.1109/TIE.2002.803237
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The conventional high-frequency phase-shifted zero-voltage-switching (ZVS) full-bridge dc/dc converter has a disadvantage, in that a circulating current flows through transformer and switching devices during the freewheeling interval. Due to this circulating current, rms current stress, conduction losses of the transformer and switching devices are increased. To alleviate this problem, this paper proposes an improved zero-voltage zero-current switching (ZVZCS) phase-shifted full-bridge (FB) dc/dc converter with a modified energy-recovery snubber (ERS) attached at the secondary side of transformer. Also, the small signal model of the proposed ZVZCS FB dc/dc converter is derived by incorporating the effects introduced by a transformer leakage inductance and an ERS to achieve ZVZCS. Both analysis and experiment are performed to verify the proposed topology by implementing a 7-kW (120 Vdc, 58 A) 30-kHz insulated-gate-bipolar-transistor-based experimental circuit.
引用
收藏
页码:1120 / 1127
页数:8
相关论文
共 4 条
[1]  
Cho JG, 1998, APPL POWER ELECT CO, P834, DOI 10.1109/APEC.1998.653995
[2]  
HAMADA S, 1993, P EUR C POW EL APPL, P130
[3]   An improved soft-switching PWM FB dc/dc converter for reducing conduction losses [J].
Kim, ES ;
Joe, KY ;
Kye, MH ;
Kim, YH ;
Yoon, BD .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 1999, 14 (02) :258-264
[4]  
Vlatkovic V., 1992, IEEE Transactions on Power Electronics, V7, P128, DOI 10.1109/63.124585