Demonstrating the comparability of certified reference materials

被引:12
作者
Duewer, David L. [1 ]
Lippa, Katrice A. [1 ]
Long, Stephen E. [1 ]
Murphy, Karen E. [1 ]
Sharpless, Katherine E. [1 ]
Sniegoski, Lorna T. [1 ]
Welch, Michael J. [1 ]
Tani, Wataru [2 ]
Umemoto, Masao [2 ]
机构
[1] NIST, Div Analyt Chem, Gaithersburg, MD 20899 USA
[2] Reference Mat Inst Clin Chem Stand, KSP R&D A205, Kawasaki Ku, Kanagawa 2130012, Japan
关键词
Certified reference material (CRM); Cholesterol in human serum; Errors-in-variables regression; Graphical communication; Joint Committee on Traceability in Laboratory Medicine (JCTLM); Metrological traceability; Potassium in human serum; MASS-SPECTROMETRY; DEFINITIVE METHOD; UNCERTAINTY; POTASSIUM; SERUM;
D O I
10.1007/s00216-009-2949-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Certified reference materials (CRMs) enable the meaningful comparison of measurement results over time and place. When CRMs are used to calibrate or verify the performance of a measurement system, results produced by that system can be related through the CRM to well-defined, stable, and globally accessible reference(s). Properly done, this directly establishes the metrological traceability of the results. However, achieving the meaningful comparison of results from measurement systems calibrated and/or verified with different CRMs requires that the different materials truly deliver the same measurand, that is, are "the same" within stated uncertainty except for differences in the level of the analyte of interest. We here detail experimental and data analysis techniques for establishing and demonstrating the comparability of materials. We focus on (1) establishing a uniform interpretation of the common forms of CRM uncertainty statements, (2) estimating consistent measurement system response uncertainties from sometimes inconsistent experimental designs, (3) using "errors-in-variables" analysis methods to evaluate comparability studies and novel graphical tools for communicating results of the evaluation to reviewing authorities and potential CRM customers, and (4) augmenting established comparability studies with new materials using measurements provided by the certifying institution. These experimental and data analytic tools were developed in support of the Joint Committee for Traceability in Laboratory Medicine's efforts to enhance the reliability of clinical laboratory measurements and are illustrated with potassium and cholesterol measurands of clinical relevance; however, these tools can be applied to any group of materials that deliver the same nominal measurand with stated value and uncertainty.
引用
收藏
页码:155 / 169
页数:15
相关论文
共 20 条
  • [1] [Anonymous], 2008, 200 JCGM, V200
  • [2] [Anonymous], 2001, 61432001 ISO
  • [3] [Anonymous], 2019, The New International System of Units (SI)-Quantum Metrology and Quantum Standards, DOI 10.4324/9781351048989
  • [4] [Anonymous], 1994, ISO 5725-2 Accuracy (trueness and precision) of measurement methods and results - Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method
  • [5] Armbruster David, 2007, Clin Biochem Rev, V28, P105
  • [6] *CLIN LAB STAND I, 2002, EP09A2 METH COMP BIA
  • [7] CORNBLEET PJ, 1979, CLIN CHEM, V25, P432
  • [8] Deming WE., 1943, Statistical adjustment of data
  • [9] IMPROVING RELIABILITY OF FACTOR-ANALYSIS OF CHEMICAL DATA BY UTILIZING MEASURED ANALYTICAL UNCERTAINTY
    DUEWER, DL
    KOWALSKI, BR
    FASCHING, JL
    [J]. ANALYTICAL CHEMISTRY, 1976, 48 (13) : 2002 - 2010
  • [10] DETERMINATION OF SERUM-CHOLESTEROL BY A MODIFICATION OF THE ISOTOPE-DILUTION MASS-SPECTROMETRIC DEFINITIVE METHOD
    ELLERBE, P
    MEISELMAN, S
    SNIEGOSKI, LT
    WELCH, MJ
    WHITE, E
    [J]. ANALYTICAL CHEMISTRY, 1989, 61 (15) : 1718 - 1723