Diagnostic value of 16-slice multidetector computed tomography in symptomatic patients with suspected significant obstructive coronary artery disease

被引:19
作者
Erdogan, Nihan
Akar, Nihal
Vural, Murat
Canbay, Alper
Kayhan, Tugba
Sahin, Deniz
Diker, Erdem
Aydogdu, Sinan
机构
[1] Med Mar Diagnost Ctr, Dept Radiol, Ankara, Turkey
[2] Numune Educ & Res Hosp, Dept Cardiol, Ankara, Turkey
关键词
coronary angiography; multidetector computed tomography; coronary artery disease;
D O I
10.1007/s00380-005-0903-z
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We investigated the diagnostic value and limitations of 16-slice multidetector computed tomography (MDCT) to detect significant obstructive coronary artery disease in symptomatic patients. A total of 43 symptomatic patients underwent conventional coronary angiography and 16-slice multidetector computed tomography for the detection of significant obstructive coronary artery disease. The diagnostic value and limitations of 16-slice multidetector computed tomography to detect significant coronary stenoses were determined by analyzing all coronary arteries and proximal segments, both including and excluding unevaluable segments. Analysis of all 592 coronary artery segments demonstrated moderate sensitivity (67%) and positive predictive value (69%), with a high specificity (95%) and negative predictive value (94%) for the detection of significant coronary artery stenoses. When the unevaluable segments had been excluded, with the analysis of all evaluable segments, proximal segments, and evaluable proximal segments, sensitivity increased (71%, 77%, and 83%, respectively), and high specificity (95%, 96%, and 96%, respectively) and negative predictive value (95%) were maintained. When we repeated the analysis taking only the patients into account, 16-slice MDCT correctly diagnosed 88% of all patients but a moderate negative predictive value (63%) was obtained. Artifacts caused by cardiac motion were the most frequent reason for unevaluable segments. Calcification was the leading cause of degraded image quality and incorrect diagnosis. Our results demonstrated that 16-slice MDCT has a moderate diagnostic value for the correct diagnosis of symptomatic patients with significant coronary artery disease. This result suggests that 16-slice MDCT may not be able to exclude significant coronary artery disease reliably in patients at high risk.
引用
收藏
页码:278 / 284
页数:7
相关论文
共 18 条
[1]  
Achenbach S, 2001, CIRCULATION, V103, P2535
[2]  
Austen WG, 1975, CIRCULATION S4, V51, P5
[3]   Noninvasive detection of coronary stenosis using 16-slice detector computed tomography in carefully selected patients [J].
Beck, T ;
Kuettner, A ;
Burgstahler, C ;
Brückner, A ;
Heuschmid, M ;
Herdeg, C ;
Kopp, AE ;
Claussen, CD ;
Schroeder, S .
MEDIZINISCHE KLINIK, 2004, 99 (11) :645-650
[4]  
GAUDIO C, 2005, EUR REV MED PHARM SC, V9, P132
[5]   Predictive value of 16-slice multidetector spiral computed tomography to detect significant obstructive coronary artery disease in patients at high risk for coronary artery disease - Patient-versus segment-based analysis [J].
Hoffmann, U ;
Moselewski, F ;
Cury, RC ;
Ferencik, M ;
Jang, IK ;
Diaz, LJ ;
Abbara, S ;
Brady, TJ ;
Achenbach, S .
CIRCULATION, 2004, 110 (17) :2638-2643
[6]   Usefulness of multislice spiral computed tomography angiography for determination of coronary artery stenoses [J].
Knez, A ;
Becker, CR ;
Leber, A ;
Ohnesorge, B ;
Becker, A ;
White, C ;
Haberl, R ;
Reiser, MF ;
Steinbeck, G .
AMERICAN JOURNAL OF CARDIOLOGY, 2001, 88 (10) :1191-+
[7]  
KNEZ A, 2002, AM J CARDIOL, V89, P913
[8]   Diagnostic accuracy of multidetector computed tomography coronary angiography in with angiographically proven coronary artery disease patients [J].
Kuettner, A ;
Kopp, AF ;
Schroeder, S ;
Rieger, T ;
Brunn, J ;
Meisner, C ;
Heuschmid, M ;
Trabold, T ;
Burgstahler, C ;
Martensen, J ;
Schoebel, W ;
Selbmann, HK ;
Claussen, CD .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (05) :831-839
[9]   Diagnostic accuracy of noninvasive coronary imaging using 16-detector slice spiral computed tomography with 188 ms temporal resolution [J].
Kuettner, A ;
Beck, T ;
Drosch, T ;
Kettering, K ;
Heuschmid, M ;
Burgstahler, C ;
Claussen, CD ;
Kopp, AF ;
Schroeder, S .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (01) :123-127
[10]   Noninvasive detection of coronary lesions using 16-detector multislice spiral computed tomography technology - Initial clinical results [J].
Kuettner, A ;
Trabold, T ;
Schroeder, S ;
Feyer, A ;
Beck, T ;
Brueckner, A ;
Heuschmid, M ;
Burgstahler, C ;
Kopp, AF ;
Claussen, CD .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 44 (06) :1230-1237