Centric scan SPRITE magnetic resonance imaging: optimization of SNR, resolution, and relaxation time mapping

被引:93
作者
Halse, M
Rioux, J
Romanzetti, S
Kaffanke, J
MacMillan, B
Mastikhin, I
Shah, NJ
Aubanel, E
Balcom, BJ [1 ]
机构
[1] Univ New Brunswick, Dept Phys, MRI Ctr, Fredericton, NB E3B 5A3, Canada
[2] IME Forschungszentrum Juelich, MR Grp, Julich, Germany
[3] Univ New Brunswick, Fac Comp Sci, Fredericton, NB E3B 5A3, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Conical-SPRITE; Spiral-SPRITE; chirp z-transform; T-2; mappings; point spread function; MRI;
D O I
10.1016/j.jmr.2004.04.008
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Two strategies for the optimization of centric scan SPRITE (single point ramped imaging with T-1 enhancement) magnetic resonance imaging techniques are presented. Point spread functions (PSF) for the centric scan SPRITE methodologies are numerically simulated, and the blurring manifested in a centric scan SPRITE image through PSF convolution is characterized. Optimal choices of imaging parameters and k-space sampling scheme are predicted to obtain maximum signal-to-noise ratio (SNR) while maintaining acceptable image resolution. The point spread function simulation predictions are verified experimentally. The acquisition of multiple FID points following each RF excitation is described and the use of the Chirp z-Transform algorithm for the scaling of field of view (FOV) of the reconstructed images is illustrated. Effective recombination of the resealed images for SNR improvement and T-2* mapping is demonstrated. (C) 2004 Elsevier Inc. All rights reserved.
引用
收藏
页码:102 / 117
页数:16
相关论文
共 13 条
[1]  
Balcom B.J., 1998, SPATIALLY RESOLVED M, P75
[2]   Single-point ramped imaging with T-1 enhancement (SPRITE) [J].
Balcom, BJ ;
MacGregor, RP ;
Beyea, SD ;
Green, DP ;
Armstrong, RL ;
Bremner, TW .
JOURNAL OF MAGNETIC RESONANCE SERIES A, 1996, 123 (01) :131-134
[3]   Relaxation time mapping of short T2* nuclei with single-point imaging (SPI) methods [J].
Beyea, SD ;
Balcom, BJ ;
Prado, PJ ;
Cross, AR ;
Kennedy, CB ;
Armstrong, RL ;
Bremner, TW .
JOURNAL OF MAGNETIC RESONANCE, 1998, 135 (01) :156-164
[4]   FAST FOURIER-TRANSFORMS FOR NONEQUISPACED DATA [J].
DUTT, A ;
ROKHLIN, V .
SIAM JOURNAL ON SCIENTIFIC COMPUTING, 1993, 14 (06) :1368-1393
[5]   SENSITIVITY AND RESOLUTION OF CONSTANT-TIME IMAGING [J].
GRAVINA, S ;
CORY, DG .
JOURNAL OF MAGNETIC RESONANCE SERIES B, 1994, 104 (01) :53-61
[6]   Centric scan SPRITE magnetic resonance imaging [J].
Halse, M ;
Goodyear, DJ ;
MacMillan, B ;
Szomolanyi, P ;
Matheson, D ;
Balcom, BJ .
JOURNAL OF MAGNETIC RESONANCE, 2003, 165 (02) :219-229
[7]  
HEID O, 1998, 6 ANN M INT SOC MAGN, P2186
[8]  
Jeruchim M.C., 1992, SIMULATION COMMUNICA
[9]   Three-dimensional magnetic resonance imaging of rigid polymeric materials using single-point ramped imaging with T1 enhancement (SPRITE) [J].
Kennedy, CB ;
Balcom, BJ ;
Mastikhin, IV .
CANADIAN JOURNAL OF CHEMISTRY-REVUE CANADIENNE DE CHIMIE, 1998, 76 (11) :1753-1765
[10]   SPRITE MRI with prepared magnetization and centric k-space sampling [J].
Mastikhin, IV ;
Balcom, BJ ;
Prado, PJ ;
Kennedy, CB .
JOURNAL OF MAGNETIC RESONANCE, 1999, 136 (02) :159-168