Performance of an elliptical centric view order for signal enhancement and motion artifact suppression in breath-hold three-dimensional gradient echo imaging

被引:124
作者
Wilman, AH [1 ]
Riederer, SJ [1 ]
机构
[1] MAYO CLIN & MAYO FDN,MR RES LAB,ROCHESTER,MN 55905
关键词
centric phase encoding order; Gd-enhanced MR angiography; 3DFT MR imaging;
D O I
10.1002/mrm.1910380516
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
An elliptical centric phase-encoding (PE) order is applied to steady-state 3DFT imaging as performed during a single breath-hold or following contrast agent administration. In a set of simulation, phantom, and in vivo experiments, this truly centric RE order is shown to be both more resistant to breathing artifact and more capable of suppressing undesirable venous signals that can arise following peak arterial enhancement than a number of other centric RE techniques that are presently in use. Unlike other RE orders, the elliptical centric ordering changes with the relative dimensions of the two RE fields of view and is optimal based on increasing k-space radius. It thus creates a temporally diminishing importance to the RE order. The specific advantages of such an acquisition are demonstrated.
引用
收藏
页码:793 / 802
页数:10
相关论文
共 17 条
[1]   CENTRIC PHASE-ENCODING ORDER IN 3-DIMENSIONAL MP-RAGE SEQUENCES - APPLICATION TO ABDOMINAL IMAGING [J].
BAMPTON, AEH ;
RIEDERER, SJ ;
KORIN, HW .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1992, 2 (03) :327-334
[2]  
DEBBINS JP, 1996, P ISMRM 4 ANN M, P1427
[3]   Automated detection of bolus arrival and initiation of data acquisition in fast, three-dimensional, gadolinium-enhanced MR angiography [J].
Foo, TKF ;
Saranathan, M ;
Prince, MR ;
Chenevert, TL .
RADIOLOGY, 1997, 203 (01) :275-280
[4]  
HAACKE EM, 1986, MAGN RESON IMAGING, V4, P962
[5]  
KANAL E, 1991, RADIOLOGY P, V181, P119
[6]   ALTERED PHASE-ENCODING ORDER FOR REDUCED SENSITIVITY TO MOTION IN 3-DIMENSIONAL MR IMAGING [J].
KORIN, HW ;
RIEDERER, SJ ;
BAMPTON, AEH ;
EHMAN, RL .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1992, 2 (06) :687-693
[7]   Time-resolved contrast-enhanced 3D MR angiography [J].
Korosec, FR ;
Frayne, R ;
Grist, TM ;
Mistretta, CA .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (03) :345-351
[8]   CORONARY-ARTERIES - 3-DIMENSIONAL MR-IMAGING WITH FAT SATURATION AND MAGNETIZATION TRANSFER CONTRAST [J].
LI, D ;
PASCHAL, CB ;
HAACKE, EM ;
ADLER, LP .
RADIOLOGY, 1993, 187 (02) :401-406
[9]   A MONITORING, FEEDBACK, AND TRIGGERING SYSTEM FOR REPRODUCIBLE BREATH-HOLD MR-IMAGING [J].
LIU, YL ;
RIEDERER, SJ ;
ROSSMAN, PJ ;
GRIMM, RC ;
DEBBINS, JP ;
EHMAN, RL .
MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (04) :507-511
[10]   The effects of time varying intravascular signal intensity and k-space acquisition order on three-dimensional MR angiography image quality [J].
Maki, JH ;
Prince, MR ;
Londy, FJ ;
Chenevert, TL .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (04) :642-651