Selection of the wavelength range and spectrophotometric determination of leucovorin and methotrexate in human serum by a net analyte signal based method

被引:30
作者
Espinosa-Mansilla, A [1 ]
Merás, ID [1 ]
Gómez, MJR [1 ]
de la Peña, AM [1 ]
Salinas, F [1 ]
机构
[1] Univ Extremadura, Fac Sci, Dept Analyt Chem, E-06071 Badajoz, Spain
关键词
methotrexate; leucovorin; net analyte signal; hybrid linear analysis;
D O I
10.1016/S0039-9140(02)00243-6
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学]; 081704 [应用化学];
摘要
Leucovorin (LV) and methotrexate (MTX) were determined in human blood serum samples by using a model based in the net analytical signal concept. The calibration method used is a variation of the original hybrid linear analysis (HLA) method, developed by Goicoechea and Olivieri (HLA/GO). The calibration set was composed by nine serum samples with different amounts of LV and MTX in the range of 0-10 mug ml(-1). The selection of the optimum wavelength range involved the calculation of the net analyte signal regression plot for each test sample, in conjunction with the calculation of the minimum error indicator. Relative errors of prediction (REP, %) of 3.0 and 5.3% were calculated for LV and MTX, respectively. Only two factors were necessary to optimize the proposed HLA/GO model. Sensitivity, selectivity, analytical sensitivity and limit of detection of the proposed procedure were calculated. Detection limits of 0.34 and 0.93 mug ml(-1) for LV and MTX were determined. The proposed model was tested in the analysis of serum samples, without previous separation steps, obtaining recovery values between 96 and 99%, and between 92 and 103% for LV and MTX, respectively. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:255 / 263
页数:9
相关论文
共 33 条
[1]
HIGH-DOSE METHOTREXATE - A CRITICAL REAPPRAISAL [J].
ACKLAND, SP ;
SCHILSKY, RL .
JOURNAL OF CLINICAL ONCOLOGY, 1987, 5 (12) :2017-2031
[2]
[Anonymous], 1989, MULTIVARIATE CALIBRA
[3]
TRACE ANALYSIS OF METHOTREXATE AND 7-HYDROXYMETHOTREXATE IN HUMAN PLASMA AND URINE BY A NOVEL HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD [J].
BECK, O ;
SEIDEMAN, P ;
WENNBERG, M ;
PETERSON, C .
THERAPEUTIC DRUG MONITORING, 1991, 13 (06) :528-532
[4]
HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF METHOTREXATE, 7-HYDROXYMETHOTREXATE, 5-METHYLTETRAHYDROFOLIC ACID AND FOLINIC ACID IN SERUM AND CEREBROSPINAL-FLUID [J].
BELZ, S ;
FRICKEL, C ;
WOLFROM, C ;
NAU, H ;
HENZE, G .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1994, 661 (01) :109-118
[5]
An enhanced algorithm for linear multivariate calibration [J].
Berger, AJ ;
Koo, TW ;
Itzkan, I ;
Feld, MS .
ANALYTICAL CHEMISTRY, 1998, 70 (03) :623-627
[6]
BLEYER WA, 1978, CANCER-AM CANCER SOC, V41, P36, DOI 10.1002/1097-0142(197801)41:1<36::AID-CNCR2820410108>3.0.CO
[7]
2-I
[8]
BOOKSH KS, 1997, ANAL CHEM, V66, pA782
[9]
Computing detection limits in multicomponent spectroscopic analysis [J].
Boque, R ;
Rius, FX .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1997, 16 (08) :432-436
[10]
Simultaneous spectrophotometric-multivariate calibration determination of several components of ophthalmic solutions: phenylephrine, chloramphenicol, antipyrine, methylparaben and thimerosal [J].
Collado, MS ;
Mantovani, VE ;
Goicoechea, HC ;
Olivieri, AC .
TALANTA, 2000, 52 (05) :909-920