Investigation of novel incineration technology for hospital waste

被引:16
作者
Liu, Yangsheng [1 ]
Ma, Lanlan
Liu, Yushan
Kong, Guoxing
机构
[1] Peking Univ, Dept Environm Engn, Key Lab Water & Sediment Sci, Minist Educ, Beijing 100871, Peoples R China
[2] Taiyuan Chenfeng Environm Engn Co Ltd, Taiyuan 518034, Peoples R China
[3] Zhenzhou Tianchen Environm Protect Co Ltd, Zhengzhou 030006, Peoples R China
关键词
ENERGY-PRODUCTION; EMISSION FACTORS; HEAVY-METALS; FLY-ASH; COMBUSTION; VITRIFICATION; GASIFICATION; ELEMENTS; DIOXINS; PCDD/F;
D O I
10.1021/es060190z
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Conventional incineration systems for hospital waste (HW) emit large amounts of particulate matter (PM) and heavy metals, as well as dioxins, due to the large excess air ratio. Additionally, the final process residuess- bottom and fly ashes containing high levels of heavy metals and dioxinss-also constitute a serious environmental problem. These issues faced by HW incineration processes are very similar to those confronted by conventional municipal solid waste (MSW) incinerators. In our previous work, we developed a novel technology integrating drying, pyrolysis, gasification, combustion, and ash vitrification (DPGCV) in one step, which successfully solved these issues in MSW incineration. In this study, many experiments are carried out to investigate the feasibility of employing the DPGCV technology to solve the issues faced by HW incineration processes, although there was no MSW incinerator used as a HW incinerator till now. Experiments were conducted in an industrial HW incineration plant with a capacity of 24 tons per day (TPD), located in Zhenzhou, Henan Province. Results illustrated that this DPGCV technology successfully solved these issues as confronted by the conventional HW incinerators and achieved the expected results for HW incineration as it did for MSW incineration. The outstanding performance of this DPGCV technology is due to the fact that the primary chamber acted as both gasifier for organic matter and vitrifying reactor for ashes, and the secondary chamber acted as a gas combustor.
引用
收藏
页码:6411 / 6417
页数:7
相关论文
共 48 条
[1]   Incineration of different types of medical wastes: Emission factors for particulate matter and heavy metals [J].
Alvim-Ferraz, MCM ;
Afonso, SAV .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2003, 37 (14) :3152-3157
[2]  
ALVIMFERRAZ MCM, 2000, J AIR WASTE MANAGE, V50, P131
[3]  
Batterman S., 2004, Assessment of Small-Scale Incinerators for Health-Care Waste
[4]  
Berkel V, 1988, INT J ENVIRON AN CH, V34, P51
[5]   Characteristics of heavy metals on particles with different sizes from municipal solid waste incineration [J].
Chang, MB ;
Huang, CK ;
Wu, HT ;
Lin, JJ ;
Chang, SH .
JOURNAL OF HAZARDOUS MATERIALS, 2000, 79 (03) :229-239
[6]  
[陈德珍 Chen Dezhen], 2002, [上海环境科学, Shanghai Environmental Science], V21, P344
[7]  
CHEREMISINOFF PEP, 1992, COMBUSTION PRINCIPLE
[8]   Evaluation of PCDD/F congener partition in vapor/solid phases of waste incinerator flue gases [J].
Chi, KH ;
Chang, MB .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2005, 39 (20) :8023-8031
[9]  
*CHIN EPA, 2001, CHIN POLL CONTR STAN
[10]  
*CHIN EPA, 1996, ID STAND HAZ WAST