Mass accuracy and sequence requirements for protein database searching

被引:24
作者
Green, MK
Johnston, MV [1 ]
Larsen, BS
机构
[1] Univ Delaware, Dept Chem & Biochem, Newark, DE 19716 USA
[2] Dupont Co, Cent Res & Dev, Wilmington, DE 19880 USA
基金
美国国家科学基金会;
关键词
D O I
10.1006/abio.1999.4270
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
To elucidate the role of high mass accuracy in mass spectrometric peptide mapping and database searching, selected proteins were subjected to tryptic digestion and the resulting mixtures were analyzed by electrospray ionization on a 7 Tesla Fourier transform mass spectrometer with a mass accuracy of 1 ppm, Two extreme cases were examined in detail: equine apomyoglobin, which digested easily and gave very few spurious masses, and bovine alpha-lactalbumin, which under the conditions used, gave many spurious masses, The effectiveness of accurate mass measurements in minimizing false protein matches was examined by varying the mass error allowed in the search over a wide range (2-500 ppm). For the "clean" data obtained from apomyoglobin, very few masses were needed to return valid protein matches, and the mass error allowed in the search had little effect up to 500 ppm. However, in the case of alpha-lactalbumin more mass values were needed, and low mass errors increased the search specificity. Mass errors below 30 ppm were particularly useful in eliminating false protein matches when few mass values were used in the search. Collision-induced dissociation of an unassigned peak in the alpha-lactalbumin digest provided sufficient data to unambiguously identify the peak as a fragment from alpha-lactalbumin and eliminate a large number of spurious proteins found in the peptide mass search. The results show that even with a relatively high mass error (0.8 Da for mass differences between singly charged product ions), collision-induced dissociation can help identify proteins in cases where unfavorable digest conditions or modifications render digest peaks unidentifiable by a simple mass mapping search. (C) 1999 Academic Press.
引用
收藏
页码:39 / 46
页数:8
相关论文
共 24 条
[1]  
Amster IJ, 1996, J MASS SPECTROM, V31, P1325
[2]  
Cao P, 1998, RAPID COMMUN MASS SP, V12, P864, DOI 10.1002/(SICI)1097-0231(19980715)12:13<864::AID-RCM244>3.0.CO
[3]  
2-G
[4]   RAPID MASS-SPECTROMETRIC PEPTIDE SEQUENCING AND MASS MATCHING FOR CHARACTERIZATION OF HUMAN-MELANOMA PROTEINS ISOLATED BY 2-DIMENSIONAL PAGE [J].
CLAUSER, KR ;
HALL, SC ;
SMITH, DM ;
WEBB, JW ;
ANDREWS, LE ;
TRAN, HM ;
EPSTEIN, LB ;
BURLINGAME, AL .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1995, 92 (11) :5072-5076
[5]   Evaluation of algorithms used for cross-species proteome characterisation [J].
Cordwell, SJ ;
HumpherySmith, I .
ELECTROPHORESIS, 1997, 18 (08) :1410-1417
[6]  
Dienes T, 1996, MASS SPECTROM REV, V15, P163, DOI 10.1002/(SICI)1098-2787(1996)15:3<163::AID-MAS2>3.0.CO
[7]  
2-G
[8]   Protein identification using mass spectrometric information [J].
Fenyö, D ;
Qin, J ;
Chait, BT .
ELECTROPHORESIS, 1998, 19 (06) :998-1005
[9]   Distinguishing small molecular mass differences of proteins by mass spectrometry [J].
Green, MK ;
Vestling, MM ;
Johnston, MV ;
Larsen, BS .
ANALYTICAL BIOCHEMISTRY, 1998, 260 (02) :204-211
[10]   Proteome research: Complementarity and limitations with respect to the RNA and DNA worlds [J].
HumpherySmith, I ;
Cordwell, SJ ;
Blackstock, WP .
ELECTROPHORESIS, 1997, 18 (08) :1217-1242