Computer-based detection of diabetes retinopathy stages using digital fundus images

被引:137
作者
Acharya, U. R. [1 ]
Lim, C. M. [1 ]
Ng, E. Y. K. [2 ]
Chee, C. [3 ]
Tamura, T. [4 ]
机构
[1] Ngee Ann Polytech, Dept Elect & Comp Engn, Singapore 599489, Singapore
[2] Nanyang Technol Univ, Coll Engn, Sch Mech & Aerosp Engn, Singapore, Singapore
[3] Natl Univ Singapore Hosp, Dept Ophthalmol, NUH Eye Surg, Singapore 117548, Singapore
[4] Chiba Univ, Dept Med Syst Engn, Chiba, Japan
关键词
image; diabetes; retinopathy; morphology; support vector machine; eye; microaneurysms; exudates; haemorrhages; AUTOMATED DETECTION;
D O I
10.1243/09544119JEIM486
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Diabetes mellitus is a heterogeneous clinical syndrome characterized by hyperglycaemia and the long-term complications are retinopathy, neuropathy, nephropathy, and cardiomyopathy. It is a leading cause of blindness. Diabetic retinopathy is the progressive pathological alterations in the retinal microvasculature, leading to areas of retinal non-perfusion, increased vascular permeability, and the pathological proliferation of retinal vessels. Hence, it is beneficial to have regular cost-effective eye screening for diabetes subjects. Nowadays, different stages of diabetes retinopathy are detected by retinal examination using indirect biomicroscopy by senior ophthalmologists. In this work, morphological image processing and support vector machine (SVM) techniques were used for the automatic diagnosis of eye health. In this study, 331 fundus images were analysed. Five groups were identified: normal retina, mild non-proliferative diabetic retinopathy, moderate non-proliferative diabetic retinopathy, severe non-proliferative diabetic retinopathy, and proliferative diabetic retinopathy. Four salient features blood vessels, microaneurysms, exudates, and haemorrhages were extracted from the raw images using image-processing techniques and fed to the SVM for classification. A sensitivity of more than 82 per cent and specificity of 86 per cent was demonstrated for the system developed.
引用
收藏
页码:545 / 553
页数:9
相关论文
共 33 条
[1]  
Acharya R, 2008, ARTECH HSE BIOINF BI, P1
[2]  
[Anonymous], 2000, Support Vector Machines and Other Kernel-based Learning Methods
[3]  
[Anonymous], [No title captured], DOI DOI 10.1023/A:1009715923555
[4]  
[Anonymous], 2003, PRACTICAL GUIDE SUPP
[5]  
[Anonymous], DIABETIC RETINOPATHY
[6]  
[Anonymous], DIABETES RETINOPATHY
[7]   Design and implementation of a unique blood-vessel detection algorithm towards early diagnosis of diabetic retinopathy [J].
Dua, S ;
Kandiraju, N ;
Thompson, HW .
ITCC 2005: International Conference on Information Technology: Coding and Computing, Vol 1, 2005, :26-31
[8]   Screening for diabetic retinopathy using computer based image analysis and statistical classification [J].
Ege, BM ;
Hejlesen, OK ;
Larsen, OV ;
Moller, K ;
Jennings, B ;
Kerr, D ;
Cavan, DA .
COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2000, 62 (03) :165-175
[9]  
Englmeier KH, 2004, EUR J MED RES, V9, P473
[10]   DIABETIC-RETINOPATHY [J].
FRANK, RN .
PROGRESS IN RETINAL AND EYE RESEARCH, 1995, 14 (02) :361-392