Robust Correction of Spike Noise: Application to Diffusion Tensor Imaging

被引:17
作者
Chavez, S. [1 ]
Storey, P. [2 ]
Graham, S. J. [3 ,4 ]
机构
[1] Sunnybrook Hlth Sci Ctr, Toronto, ON M4N 3M5, Canada
[2] NYU, Dept Radiol, Sch Med, New York, NY 10016 USA
[3] Univ Toronto, Rotman Res Inst, Baycrest Ctr Geriatr Care, Toronto, ON M5S 1A1, Canada
[4] Univ Toronto, Dept Med Biophys, Toronto, ON M5S 1A1, Canada
关键词
diffusion tensor imaging; spike noise; outlier detection; ripple artifact; ECHO; IMAGES; MRI;
D O I
10.1002/mrm.22019
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
Echo-planar imaging (EPI)-based diffusion tensor imaging (DTI) is particularly prone to spike noise. However, existing spike noise correction methods are impractical for corrupted DTI data because the methods correct the complex MRI signal, which is not usually stored on clinical MRI systems. The present work describes a novel Outlier Detection De-spiking technique (ODD) that consists of three steps: detection, localization, and correction. Using automated outlier detection schemes, ODD exploits the data redundancy available in DTI data sets that are acquired with a minimum of six different diffusion-weighted images (DWIs) with similar signal and noise properties. A mathematical formulation, describing the effects of spike noise on magnitude images, yields appropriate measures for an outlier detection scheme used for spike detection while a normalization-dependent outlier detection scheme is used for spike localization. ODD performs accurately on diverse DTI data sets corrupted by spike noise and can be used for automated control of DTI data quality. ODD can also be extended to other MRI applications with data redundancy, such as dynamic imaging and functional MRI. Magn Reson Med 62:510-519, 2009. (C) 2009 Wiley-Liss, Inc.
引用
收藏
页码:510 / 519
页数:10
相关论文
共 19 条
[1]
Basser PJ, 1996, J MAGN RESON SER B, V111, P209, DOI 10.1016/j.jmr.2011.09.022
[2]
ESTIMATION OF THE EFFECTIVE SELF-DIFFUSION TENSOR FROM THE NMR SPIN-ECHO [J].
BASSER, PJ ;
MATTIELLO, J ;
LEBIHAN, D .
JOURNAL OF MAGNETIC RESONANCE SERIES B, 1994, 103 (03) :247-254
[3]
CHAVEZ S, 2007, P 12 ANN M ISMRM BER
[4]
SNORE - SPIKE NOISE REMOVAL AND DETECTION [J].
FOO, TKF ;
GRIGSBY, NS ;
MITCHELL, JD ;
SLAYMAN, BE .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1994, 13 (01) :133-136
[5]
GNANADESIKAN R, 1997, METHODS STAT DATA AN
[6]
MEASUREMENT OF SIGNAL INTENSITIES IN THE PRESENCE OF NOISE IN MR IMAGES [J].
HENKELMAN, RM .
MEDICAL PHYSICS, 1985, 12 (02) :232-233
[7]
HENKELMAN RM, 1987, REV MAGN RESON MED, V2, P32
[8]
A survey of outlier detection methodologies [J].
Hodge V.J. ;
Austin J. .
Artificial Intelligence Review, 2004, 22 (2) :85-126
[9]
DtiStudio: Resource program for diffusion tensor computation and fiber bundle tracking [J].
Jiang, HY ;
van Zijl, PCM ;
Kim, J ;
Pearlson, GD ;
Mori, S .
COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2006, 81 (02) :106-116
[10]
Jones DK, 1999, MAGN RESON MED, V42, P37, DOI 10.1002/(SICI)1522-2594(199907)42:1<37::AID-MRM7>3.0.CO