Acetabular revision THA with use of a large (jumbo) cup is an effective treatment for many cavitary and segmental peripheral bone defects. However, hip center elevation may occur with use of a jumbo cup owing to reaming superiorly and/or because of the increased diameter of the jumbo cup compared with the native acetabulum. In our jumbo cup revision THAs, we attempted to avoid hip center elevation by placing the inferior edge of the cup at the inferior acetabulum. In this study, we asked (1) how much of an elevation in the hip center is observed radiographically with use of jumbo cups, and (2) how effective was our technique in minimizing hip center elevation during revision THA in clinical practice? We retrospectively reviewed radiographic data for all patients, from one surgeon's practice, who received a jumbo cup (defined as cup size a parts per thousand yen 66 mm in men, a parts per thousand yen 62 mm in women) during an acetabular revision between 1998 and 2012 and who had an anatomically placed THA or no THA on the contralateral side (so as to be able to make comparisons); 98 patients were identified and included. The height of the revised hip center was measured relative to the contralateral normal hip. Cup elevation resulting from superior reaming was determined by measuring the distance from the inferior cup edge to the interteardrop line. The mean hip center elevation and cup position relative to the interteardrop line in male and female patients were compared using unpaired t-tests. Radiographic analysis showed a mean hip center elevation of 11 mm. On average, 1 mm of the measured hip center elevation was the result of cup placement superior to its planned position at the interteardop line. Our results indicate that revision THA with a jumbo cup is associated with hip center elevation despite placement of the cup at the inferior acetabulum. An increase in femoral head length may be needed to compensate for hip center elevation with use of a jumbo cup. Level III, therapeutic study. See the Instructions for Authors for a complete description of levels of evidence.
引用
收藏
页码:2793 / 2798
页数:6
相关论文
共 13 条
[1]
Acetabular revision arthroplasty using so-called jumbo cementless components - An average 7-year follow-up study [J].
Dearborn, JT ;
Harris, WH .
JOURNAL OF ARTHROPLASTY, 2000, 15 (01) :8-15
[2]
Delp SL, 1996, CLIN ORTHOP RELAT R, P137
[3]
Medial protrusio technique for placement of a porous-coated, hemispherical acetabular component without cement in a total hip arthroplasty in patients who have acetabular dysplasia [J].
Dorr, LD ;
Tawakkol, S ;
Moorthy, M ;
Long, W ;
Wan, ZN .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (01) :83-92
[4]
Leg-Length Discrepancy After Revision Hip Arthroplasty: Are Modular Stems Superior? [J].
Dou, Yong ;
Zhou, Yixin ;
Tang, Qiheng ;
Yang, Dejin ;
Liu, Jian .
JOURNAL OF ARTHROPLASTY, 2013, 28 (04) :676-679
[5]
Acetabular Cup Revision With the Use of the Medial Protrusio Technique at an Average Follow-up of 6.6 Years [J].
Fabi, David ;
Gonzalez, Mark ;
Goldstein, Wayne ;
Ahmed, Muhammad .
JOURNAL OF ARTHROPLASTY, 2010, 25 (02) :197-202
[6]
Jumbo cup or high hip center - Is bigger better? [J].
Gustke, KA .
JOURNAL OF ARTHROPLASTY, 2004, 19 (04) :120-123
[7]
High placement of noncemented acetabular components in revision total hip arthroplasty - A concise follow-up, at a minimum of fifteen years, of a previous report [J].
Hendricks, Kelly J. ;
Harris, William H. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A (10) :2231-2236
[8]
Jumbo cups and morselized graft [J].
Jasty, M .
ORTHOPEDIC CLINICS OF NORTH AMERICA, 1998, 29 (02) :249-+
[9]
Lachiewicz PE, 2013, J BONE JOINT SURG AM, V95A, P543, DOI [10.2106/JBJS.L.0758, 10.2106/JBJS.L.00758]
[10]
Do Jumbo Cups Cause Hip Center Elevation in Revision THA? A Computer Simulation [J].
Nwankwo, Chima ;
Dong, Nick N. ;
Heffernan, Christopher D. ;
Ries, Michael D. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2014, 472 (02) :572-576