Physico/chemical characterization and in vivo evaluation of nanothickness bioceramic depositions on alumina-blasted/acid-etched Ti-6Al-4V implant surfaces

被引:86
作者
Coelho, Paulo G. [1 ]
Lemons, Jack E. [2 ]
机构
[1] NYU, Dept Biomat & Biomimet, New York, NY 10010 USA
[2] Univ Alabama, Dept Prosthodont & Biomat, Birmingham, AL 35294 USA
关键词
implant surface; bioceramic; nanothickness; surface characterization; animal model; histomorphometric; biomechanical; PLASMA-SPRAYED HYDROXYAPATITE; CALCIUM-PHOSPHATE COATINGS; TITANIUM SURFACE; PART; BIOMECHANICAL EVALUATION; ENDOSSEOUS IMPLANTS; ROUGHENED TITANIUM; CERAMIC COATINGS; TRABECULAR BONE; TERM ADHESION;
D O I
10.1002/jbm.a.32097
中图分类号
R318 [生物医学工程];
学科分类号
100103 [病原生物学];
摘要
The objective of this study was to physico/chemically characterize and evaluate the in vivo performance of two nanothickness ion beam assisted depositions (IBAD) of bioceramic coatings on implants in a beagle model. Alumina-blasted/acid-etched (AB/AE) Ti-6Al-4V implants were subjected to two different IBAD depositions (IBAD I and IBAD 11), which were physico/chemically characterized by SEM, EDS, XPS, XPS + ion-beam milling (depth profiling), XRD, AFM, and ToF-SIMS. A beagle dog tibia model was utilized for histomorphometric and biomechanical (torque) comparison between AB/AE, IBAD I, BAD II, and plasma-sprayed hydroxyapatite (PSHA) coated implants that remained hi vivo for 3 and 5 weeks. The coatings were characterized as amorphous Ca-P with high Ca/P stoichiometries with thicknesses of an order of magnitude difference (IBAD I = 30-50 nm and IBAD II = 300-500 nm). The histomorphometric and biomechanical testing results showed that the 300-500 nm thickness deposition (IBAD II) and PSHA positively modulated bone healing at early implantation times. (C) 2008 Wiley Periodicals, Inc. J Biomed Mater Res 90A: 351-361, 2009
引用
收藏
页码:351 / 361
页数:11
相关论文
共 47 条
[1]
Albrektsson T, 2004, INT J PROSTHODONT, V17, P544
[2]
Albrektsson T, 2004, INT J PROSTHODONT, V17, P536
[3]
Anselme K, 2000, J BIOMED MATER RES, V49, P155, DOI 10.1002/(SICI)1097-4636(200002)49:2<155::AID-JBM2>3.0.CO
[4]
2-J
[5]
Statistical demonstration of the relative effect of surface chemistry and roughness on human osteoblast short-term adhesion [J].
Anselme, K ;
Bigerelle, M .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2006, 17 (05) :471-479
[6]
Topography effects of pure titanium substrates on human osteoblast long-term adhesion [J].
Anselme, K ;
Bigerelle, M .
ACTA BIOMATERIALIA, 2005, 1 (02) :211-222
[7]
The relative influence of the topography and chemistry of TiAl6V4 surfaces on osteoblastic cell behaviour [J].
Anselme, K ;
Linez, P ;
Bigerelle, M ;
Le Maguer, D ;
Le Maguer, A ;
Hardouin, P ;
Hildebrand, HF ;
Iost, A ;
Leroy, JM .
BIOMATERIALS, 2000, 21 (15) :1567-1577
[8]
The pathology of total joint arthroplasty I. Mechanisms of implant fixation [J].
Bauer, TW ;
Schils, J .
SKELETAL RADIOLOGY, 1999, 28 (08) :423-432
[9]
De novo alveolar bone formation adjacent to endosseous implants -: A model study in the dog [J].
Berglundh, T ;
Abrahamsson, I ;
Lang, NP ;
Lindhe, J .
CLINICAL ORAL IMPLANTS RESEARCH, 2003, 14 (03) :251-262
[10]
Highly crystalline Mp-1™ hydroxylapatite coating Part II:: In vivo performance on endosseous root implants in dogs [J].
Burgess, AV ;
Story, BJ ;
Wagner, WR ;
Trisi, P ;
Pikos, MA ;
Guttenberg, SA .
CLINICAL ORAL IMPLANTS RESEARCH, 1999, 10 (04) :257-266