Correlation of ultrasound-induced hemolysis with cavitation detector output in vitro

被引:101
作者
Everbach, EC
Makin, IRS
Azadniv, M
Meltzer, RS
机构
[1] UNIV WASHINGTON,APPL PHYS LAB,SEATTLE,WA 98105
[2] UNIV ROCHESTER,DEPT BIOPHYS,ROCHESTER,NY 14642
[3] UNIV ROCHESTER,DEPT CARDIOL,ROCHESTER,NY
关键词
ultrasound; cavitation; hemolysis; echo-contrast agents; microbubbles;
D O I
10.1016/S0301-5629(97)00039-2
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
A 20-MHz passive acoustic detector was used to quantify the amount of transient acoustic cavitation occurring in a sample exposed to intense pulsed ultrasound, A dilute suspension of human erythrocytes with and without a microbubble echo-contrast agent was exposed in vitro to 500 W/cm(2) (SPPA) ultrasound of center frequency 1 MHz and tone burst duration 20, 100, 200, 500 and 1000 mu s at a pulse repetition frequency of 20 Hz. Inertial cavitation occurring within the sample, as measured by the temporal average of the detector output, correlated well with hemolysis, suggesting that violent bubble collapse is responsible for cell damage, The result also raises the prospect of cavitation monitoring as a possible predictor of adverse bioeffects when echo-contrast agents are used clinically. (C) 1997 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:619 / 624
页数:6
相关论文
共 29 条
  • [1] *AM I ULTR MED, 1993, BIOEFF SAF DIAGN ULT, P21
  • [2] BAILEY MR, 1994, J ACOUST SOC AM, V96, P3305
  • [3] EFFECT OF A STABILIZED MICROBUBBLE ECHO CONTRAST AGENT ON HEMOLYSIS OF HUMAN ERYTHROCYTES EXPOSED TO HIGH-INTENSITY PULSED ULTRASOUND
    BRAYMAN, AA
    AZADNIV, M
    MAKIN, IRS
    MILLER, MW
    CARSTENSEN, EL
    CHILD, SZ
    RAEMAN, CH
    MELTZER, RS
    EVERBACH, EC
    [J]. ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 1995, 12 (01): : 13 - 21
  • [4] BUBBLE RECYCLING AND ULTRASONIC CELL-LYSIS IN A STATIONARY EXPOSURE VESSEL
    BRAYMAN, AA
    AZADNIV, M
    MILLER, MW
    CHEN, XC
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1994, 96 (02) : 627 - 633
  • [5] LYSIS OF ERYTHROCYTES BY EXPOSURE TO CW ULTRASOUND
    CARSTENSEN, EL
    KELLY, P
    CHURCH, CC
    BRAYMAN, AA
    CHILD, SZ
    RAEMAN, CH
    SCHERY, L
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1993, 19 (02) : 147 - 165
  • [6] TEST FOR KIDNEY HEMORRHAGE FOLLOWING EXPOSURE TO INTENSE, PULSED ULTRASOUND
    CARSTENSEN, EL
    HARTMAN, C
    CHILD, SZ
    COX, CA
    MAYER, R
    SCHENK, E
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1990, 16 (07) : 681 - 685
  • [7] SISTER-CHROMATID EXCHANGES IN HUMAN-LYMPHOCYTES EXPOSED INVITRO TO THERAPEUTIC ULTRASOUND
    CIARAVINO, V
    MILLER, MW
    CARSTENSEN, EL
    [J]. MUTATION RESEARCH, 1986, 172 (02): : 185 - 188
  • [8] ACOUSTIC CAVITATION GENERATED BY AN EXTRACORPOREAL SHOCKWAVE LITHOTRIPTER
    COLEMAN, AJ
    SAUNDERS, JE
    CRUM, LA
    DYSON, M
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1987, 13 (02) : 69 - 76
  • [9] ACOUSTIC CAVITATION PRODUCED BY MICROSECOND PULSES OF ULTRASOUND - A DISCUSSION OF SOME SELECTED RESULTS
    CRUM, LA
    ROY, RA
    DINNO, MA
    CHURCH, CC
    APFEL, RE
    HOLLAND, CK
    MADANSHETTY, SI
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1992, 91 (02) : 1113 - 1119
  • [10] FREE-RADICAL PRODUCTION IN AMNIOTIC-FLUID AND BLOOD-PLASMA BY MEDICAL ULTRASOUND
    CRUM, LA
    WALTON, AJ
    MORTIMER, A
    DYSON, M
    CRAWFORD, DC
    GAITAN, DF
    [J]. JOURNAL OF ULTRASOUND IN MEDICINE, 1987, 6 (11) : 643 - 647