Identification of sources of atmospheric PM at the Pittsburgh Supersite, Part I: Single particle analysis and filter-based positive matrix factorization

被引:37
作者
Pekney, Natalie J.
Davidson, Cliff I. [1 ]
Bein, Keith J.
Wexler, Anthony S.
Johnston, Murray V.
机构
[1] Carnegie Mellon Univ, Dept Civil & Environm Engn, Pittsburgh, PA 15213 USA
[2] Carnegie Mellon Univ, Dept Engn & Publ Policy, Pittsburgh, PA 15213 USA
[3] Univ Calif Davis, Dept Land Air & Water Resources, Davis, CA 95616 USA
[4] Univ Calif Davis, Dept Mech & Aeronaut Engn, Davis, CA 95616 USA
[5] Univ Delaware, Dept Chem & Biochem, Newark, DE 19716 USA
关键词
real-time single particle mass spectrometry; positive matrix factorization; ambient aerosols; trace elements; particle size-composition;
D O I
10.1016/j.atmosenv.2005.12.072
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
During the Pittsburgh Air Quality Study (PAQS), July 2001-September 2002, three co-located instruments analyzed the composition of ambient particulate matter (PM): (1) A single particle mass spectrometer, RSMS-3, was deployed to obtain high-temporal-resolution measurements of single particle size (> 1.1 mu m) and composition which were correlated with meteorological data to identify sources; (2) PM2.5 and PM10 were collected on cellulose filters using high-volume (hi-vol) samplers, followed by microwave-assisted digestion and analysis by inductively coupled plasma-mass spectrometry (ICP-MS). Positive matrix factorization (PMF) was used to identify possible source categories; and (3) a micro-orifice uniform-deposit impactor (MOUDI) obtained size-distributed samples of PM. Several days of MOUDI filters were selected for microwave-assisted digestion and analysis by ICP-MS. In this paper, sources identified using the single particle data were compared to the PMF results for the hi-vol/ICP-MS data. The strengths of each method were combined to hypothesize the most likely sources of various elements in ambient PM in Pittsburgh. In the final results, Mo and Cr are attributed to local specialty steel facilities; Fe, Mn, Zn, and K are attributed to a steel mill SE of the monitoring station; internally mixed Pb-containing particles are attributed to a major source to the NW; and Ga is attributed to coal combustion sources to the NW. There is a notable lack of oil combustion sources. The MOUDI data were used to resolve discrepancies between the single particle and hi-vol/ICP-MS data concerning the detection of Ti and Se. The hi-vol data showed appreciable Ti and Se masses, but RSMS-3 was unable to detect significant numbers of Ti-containing particles because of their large size, while we hypothesize that the volatility of Se caused it to be distributed more evenly over all emitted particles such that the amount of Se in any individual particle is below the limit of detection. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:S411 / S423
页数:13
相关论文
共 24 条
[1]  
Andren A.W., 1975, Environ. Sci. Technol., V9, P856, DOI [10.1021/es60107a002, DOI 10.1021/ES60107A002]
[2]  
[Anonymous], 1969, 999AP26 USEPA
[3]   Speciation of size-resolved individual ultrafine particles in Pittsburgh, Pennsylvania [J].
Bein, KJ ;
Zhao, YJ ;
Wexler, AS ;
Johnston, MV .
JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 2005, 110 (D7) :1-22
[4]  
BEIN KJ, 2005, IN PRESS ATMOSPHERIC, DOI DOI 10.1016/J.ATMOSENV.2006.01.064
[5]   Sources of atmospheric carbonaceous particulate matter in Pittsburgh, Pennsylvania [J].
Cabada, JC ;
Pandis, SN ;
Robinson, AL .
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2002, 52 (06) :732-741
[6]   Mass size distributions and size resolved chemical composition of fine particulate matter at the Pittsburgh supersite [J].
Cabada, JC ;
Rees, S ;
Takahama, S ;
Khlystov, A ;
Pandis, SN ;
Davidson, CI ;
Robinson, AL .
ATMOSPHERIC ENVIRONMENT, 2004, 38 (20) :3127-3141
[7]   VAPOR-PHASE CONCENTRATIONS OF ARSENIC, SELENIUM, BROMINE, IODINE, AND MERCURY IN THE STACK OF A COAL-FIRED POWER-PLANT [J].
GERMANI, MS ;
ZOLLER, WH .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1988, 22 (09) :1079-1085
[8]   The role of resuspended soil in lead flows in the California South Coast Air Basin [J].
Harris, AR ;
Davidson, CI .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2005, 39 (19) :7410-7415
[9]  
Hopke P.K., 1985, RECEPTOR MODELING EN
[10]   Detection of negative ions from individual ultrafine particles [J].
Kane, DB ;
Wang, JJ ;
Frost, K ;
Johnston, MV .
ANALYTICAL CHEMISTRY, 2002, 74 (09) :2092-2096