Retest variability of human infant contrast sensitivity: How many tests are sufficient?

被引:5
作者
Adams, RJ [1 ]
Courage, ML
Drover, JR
机构
[1] Mem Univ Newfoundland, Dept Psychol, St Johns, NF A1B 3X9, Canada
[2] Mem Univ Newfoundland, Dept Pediat, St Johns, NF A1B 3X9, Canada
关键词
infants; vision; contrast sensitivity; spatial vision; reliability;
D O I
10.1097/00006324-200002000-00013
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Retest variability of a new infant contrast sensitivity (CS) card procedure was assessed by binocular measurement of a group of 20 6-month-olds twice within a 1-week period. Coefficient of reliability analyses showed that within-subject variability between tests was only slightly less than variation across subjects, which suggests that results from a single test are a poor predictor of an infant's "true" visual functioning. To determine how many tests are needed to estimate when infant CS stabilizes to within an acceptable (0.15 log unit) criterion, a second experiment was conducted in which a small group of subjects was tested repeatedly over a 2-week period. The results showed that averaging performance on 2 to 3 tests was required before an accurate estimate of the subject's performance could be obtained. Our results suggest that caution should be taken in the interpretation of a single measurement of infant visual functioning.
引用
收藏
页码:90 / 95
页数:6
相关论文
共 16 条
[1]   CONTRAST SENSITIVITY IN 24-MONTH-OLDS AND 36-MONTH-OLDS AS ASSESSED WITH THE CONTRAST SENSITIVITY CARD PROCEDURE [J].
ADAMS, RJ ;
COURAGE, ML .
OPTOMETRY AND VISION SCIENCE, 1993, 70 (02) :97-101
[2]   A NEW TECHNIQUE TO MEASURE CONTRAST SENSITIVITY IN HUMAN INFANTS [J].
ADAMS, RJ ;
MERCER, ME ;
COURAGE, ML ;
VANHOFVANDUIN, J .
OPTOMETRY AND VISION SCIENCE, 1992, 69 (06) :440-446
[3]  
ADAMS RJ, 1998, INVEST OPHTH VIS SCI, V396, pS1087
[4]   MEASUREMENT IN MEDICINE - THE ANALYSIS OF METHOD COMPARISON STUDIES [J].
ALTMAN, DG ;
BLAND, JM .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES D-THE STATISTICIAN, 1983, 32 (03) :307-317
[5]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]   Stereoacuity development: 6 months to 5 years. A new tool for testing and screening [J].
Ciner, EB ;
SchanelKlitsch, E ;
Herzberg, C .
OPTOMETRY AND VISION SCIENCE, 1996, 73 (01) :43-48
[7]   Contrast sensitivity in infants and children with Down syndrome [J].
Courage, ML ;
Adams, RJ ;
Hall, EJ .
VISION RESEARCH, 1997, 37 (11) :1545-1555
[8]  
HOLMES JM, 1993, J PEDIATR OPHTHALMOL, V30, P312
[9]  
Hughes S. L., 1998, IOVS, V39, pS557
[10]   INTEROBSERVER AGREEMENT FOR MEASUREMENT OF GRATING ACUITY AND INTEROCULAR ACUITY DIFFERENCES WITH THE TELLER ACUITY CARD PROCEDURE [J].
MASH, C ;
DOBSON, V ;
CARPENTER, N .
VISION RESEARCH, 1995, 35 (02) :303-312