The fiberoptic intraparenchymal cerebral pressure monitor in 244 patients

被引:48
作者
Shapiro, S [1 ]
Bowman, R [1 ]
Callahan, J [1 ]
Wolfla, C [1 ]
机构
[1] INDIANA UNIV,MED CTR,DEPT NEUROSURG,INDIANAPOLIS,IN
来源
SURGICAL NEUROLOGY | 1996年 / 45卷 / 03期
关键词
ICP; ICP monitor; fiberoptic; intracranial pressure monitor;
D O I
10.1016/0090-3019(95)00359-2
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND The fiberoptic intraparenchymal pressure monitor has been shown to provide reliable data in patients monitored for a short period of time, An analysis of a large population, including patients monitored for a prolonged period such as weeks, has never been performed. METHODS We conducted a retrospective study in which we evaluated the fiberoptic intraparenchymal cerebral pressure monitor for complications and accuracy. RESULTS The fiberoptic intraparenchymal cerebral pressure (ICP) monitor was used in 244 patients since 1988. Pathology included trauma in 180, intracerebral hemorrhage (ICK) in 19, aneurysmal subarachnoid hemorrhage in 16, arteriovenous malformations in 10, cerebral edema in 12, and tumor in 7. The mean length of monitoring was 7 days with 49 patients (20%) monitored 1-2 days, 105 (43%) monitored 3-6 days, 48 monitored for 7-10 days (20%), and 42 (17%) monitored from 10-24 days. Seventy-four 0patients also had ventriculostomies and there was strong correlation with the TCP monitor (p < 0.001). Complications from insertion were 2 patients (0.8%) with ICH, both with hepatic dysfunction. In the group monitored greater than 6 days, 34 patients (38%) required at least one catheter change due to upward drift of the ICP. Fiberoptic breakage requiring replacement was documented in 41 patients (16%). An insertion-site infection occurred in one case monitored for 23 days. Two infected bone flaps occurred that had a monitor placed in the flap. There were no cases of bacterial meningitis or cerebral abscess. CONCLUSIONS The monitor is easy, safe, and reliable to use with a very low rate of infection, Coagulopathic patients may best be monitored by an alternative method.
引用
收藏
页码:278 / 281
页数:4
相关论文
共 13 条
[1]   INTRACRANIAL-PRESSURE MONITORS - EPIDEMIOLOGIC-STUDY OF RISK-FACTORS AND INFECTIONS [J].
AUCOIN, PJ ;
KOTILAINEN, HR ;
GANTZ, NM ;
DAVIDSON, R ;
KELLOGG, P ;
STONE, B .
AMERICAN JOURNAL OF MEDICINE, 1986, 80 (03) :369-376
[2]   COMPLICATIONS OF INTRACRANIAL-PRESSURE MONITORING IN FULMINANT HEPATIC-FAILURE [J].
BLEI, AT ;
OLAFSSON, S ;
WEBSTER, S ;
LEVY, R .
LANCET, 1993, 341 (8838) :157-158
[3]  
CATHEY SL, 1987, NEUROSURGERY, V21, P116
[4]   EVALUATION OF A FIBEROPTIC INTRACRANIAL-PRESSURE MONITOR [J].
CRUTCHFIELD, JS ;
NARAYAN, RK ;
ROBERTSON, CS ;
MICHAEL, LH .
JOURNAL OF NEUROSURGERY, 1990, 72 (03) :482-487
[5]   MONITORING OF BRAIN-TISSUE PRESSURE WITH A FIBEROPTIC DEVICE [J].
GAMBARDELLA, G ;
DAVELLA, D ;
TOMASELLO, F ;
HORWITZ, NH ;
WILKINSON, HA .
NEUROSURGERY, 1992, 31 (05) :918-922
[6]   THE SAFETY AND VALUE OF EXTRADURAL INTRACRANIAL-PRESSURE MONITORS IN FULMINANT HEPATIC-FAILURE [J].
KEAYS, RT ;
ALEXANDER, GJM ;
WILLIAMS, R .
JOURNAL OF HEPATOLOGY, 1993, 18 (02) :205-209
[7]   INTRACRANIAL-PRESSURE MONITORING AND LIVER-TRANSPLANTATION FOR FULMINANT HEPATIC-FAILURE [J].
LIDOFSKY, SD ;
BASS, NM ;
PRAGER, MC ;
WASHINGTON, DE ;
READ, AE ;
WRIGHT, TL ;
ASCHER, NL ;
ROBERTS, JP ;
SCHARSCHMIDT, BF ;
LAKE, JR .
HEPATOLOGY, 1992, 16 (01) :1-7
[8]  
MUNOZ S J, 1991, Gastroenterology, V100, pA777
[9]   INTRA-CRANICAL PRESSURE - TO MONITOR OR NOT TO MONITOR - A REVIEW OF OUR EXPERIENCE WITH SEVERE HEAD-INJURY [J].
NARAYAN, RK ;
KISHORE, PRS ;
BECKER, DP ;
WARD, JD ;
ENAS, GG ;
GREENBERG, RP ;
DASILVA, AD ;
LIPPER, MH ;
CHOI, SC ;
MAYHALL, CG ;
LUTZ, HA ;
YOUNG, HF .
JOURNAL OF NEUROSURGERY, 1982, 56 (05) :650-659
[10]   COMPARISON AMONG 3 METHODS OF INTRACRANIAL-PRESSURE RECORDING [J].
NORTH, B ;
REILLY, P .
NEUROSURGERY, 1986, 18 (06) :730-732