Doing it right the first time: Quality improvement and the contaminant blood culture

被引:101
作者
Weinbaum, FI
Lavie, S
Danek, M
Sixsmith, D
Heinrich, GF
Mills, SS
机构
[1] NEW YORK HOSP,QUEENS MED CTR,DEPT PATHOL,FLUSHING,NY 11355
[2] NEW YORK HOSP,QUEENS MED CTR,DEPT EMERGENCY MED,FLUSHING,NY 11355
[3] NEW YORK HOSP,QUEENS MED CTR,DEPT QUAL MANAGEMENT,FLUSHING,NY 11355
[4] NEW YORK HOSP,QUEENS MED CTR,DEPT ADM,FLUSHING,NY 11355
关键词
D O I
10.1128/JCM.35.3.563-565.1997
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
The aim of the project was to determine whether the rate of contaminant blood cultures could be reduced by using a team of dedicated phlebotomists. Comparisons were made between adult patients requiring blood cultures for suspected bacteremia on medical and surgical units before and after the introduction and withdrawal of a dedicated blood culture team. The results showed that a significant reduction in the contaminant blood culture rate was achieved by the blood culture team (P < 0.001; chi(2) test). Therefore, in our experience, the rate of contaminant blood cultures can be reduced in a teaching hospital by using a team of dedicated phlebotomists. Calculations made with our data and those published by others suggest that cost savings from reducing false-positive blood cultures are greater than the cost of the blood culture team.
引用
收藏
页码:563 / 565
页数:3
相关论文
共 10 条
[1]   RAPID CLASSIFICATION OF POSITIVE BLOOD CULTURES - PROSPECTIVE VALIDATION OF A MULTIVARIATE ALGORITHM [J].
BATES, DW ;
LEE, TH .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1992, 267 (14) :1962-1966
[2]   CONTAMINANT BLOOD CULTURES AND RESOURCE UTILIZATION - THE TRUE CONSEQUENCES OF FALSE-POSITIVE RESULTS [J].
BATES, DW ;
GOLDMAN, L ;
LEE, TH .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1991, 265 (03) :365-369
[3]   CONTINUOUS IMPROVEMENT AS AN IDEAL IN HEALTH-CARE [J].
BERWICK, DM .
NEW ENGLAND JOURNAL OF MEDICINE, 1989, 320 (01) :53-56
[4]  
CROBSY PB, 1979, QUALITY FREE ART MAK
[5]  
CROBSY PB, 1984, QUALITY TEARS ART HA
[6]  
DUNAGAN WC, 1989, AM J MED, V87, P253
[7]  
JURAN TM, 1992, JURAN QUALITY DESIGN
[8]  
RELLER LB, 1982, CUMITECH IA BLOOD CU, V2
[9]   THE EFFECT OF SKIN DISINFECTION MATERIALS ON REDUCING BLOOD CULTURE CONTAMINATION [J].
SCHIFMAN, RB ;
PINDUR, A .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1993, 99 (05) :536-538
[10]   EFFECT OF LODOPHOR VS IODINE TINCTURE SKIN PREPARATION ON BLOOD CULTURE CONTAMINATION RATE [J].
STRAND, CL ;
WAJSBORT, RR ;
STURMANN, K .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1993, 269 (08) :1004-1006