Biosensors for Whole-Cell Bacterial Detection

被引:470
作者
Ahmed, Asif [1 ]
Rushworth, Jo V. [1 ]
Hirst, Natalie A. [1 ]
Millner, Paul A. [1 ]
机构
[1] Univ Leeds, Fac Biol Sci, Sch Biomed Sci, Leeds, W Yorkshire, England
关键词
SURFACE-PLASMON RESONANCE; ELECTROCHEMICAL IMPEDANCE SPECTROSCOPY; ESCHERICHIA-COLI O157H7; LABEL-FREE DETECTION; HIGHLY SENSITIVE DETECTION; 16S RIBOSOMAL-RNA; REAL-TIME PCR; IMPEDIMETRIC IMMUNOSENSOR; RAPID DETECTION; SALMONELLA-TYPHIMURIUM;
D O I
10.1128/CMR.00120-13
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Bacterial pathogens are important targets for detection and identification in medicine, food safety, public health, and security. Bacterial infection is a common cause of morbidity and mortality worldwide. In spite of the availability of antibiotics, these infections are often misdiagnosed or there is an unacceptable delay in diagnosis. Current methods of bacterial detection rely upon laboratory-based techniques such as cell culture, microscopic analysis, and biochemical assays. These procedures are time-consuming and costly and require specialist equipment and trained users. Portable stand-alone biosensors can facilitate rapid detection and diagnosis at the point of care. Biosensors will be particularly useful where a clear diagnosis informs treatment, in critical illness (e.g., meningitis) or to prevent further disease spread (e.g., in case of food-borne pathogens or sexually transmitted diseases). Detection of bacteria is also becoming increasingly important in anti-bioterrorism measures (e.g., anthrax detection). In this review, we discuss recent progress in the use of biosensors for the detection of whole bacterial cells for sensitive and earlier identification of bacteria without the need for sample processing. There is a particular focus on electrochemical biosensors, especially impedance-based systems, as these present key advantages in terms of ease of miniaturization, lack of reagents, sensitivity, and low cost.
引用
收藏
页码:631 / 646
页数:16
相关论文
共 119 条
[21]   Selective Detection of Live Pathogens via Surface-Confined Electric Field Perturbation on Interdigitated Silicon Transducers [J].
de la Rica, Roberto ;
Baldi, Antonio ;
Fernandez-Sanchez, Cesar ;
Matsui, Hiroshi .
ANALYTICAL CHEMISTRY, 2009, 81 (10) :3830-3835
[22]   Specific and targeted detection of viable Escherichia coli O157:H7 using a sensitive and reusable impedance biosensor with dose and time response studies [J].
Dweik, Majed ;
Stringer, R. Cody ;
Dastider, Shibajyoti Ghosh ;
Wu, Yifan ;
Almasri, Mahmoud ;
Barizuddin, Syed .
TALANTA, 2012, 94 :84-89
[23]   Real-time PCR in clinical microbiology: Applications for a routine laboratory testing [J].
Espy, MJ ;
Uhl, JR ;
Sloan, LM ;
Buckwalter, SP ;
Jones, MF ;
Vetter, EA ;
Yao, JDC ;
Wengenack, NL ;
Rosenblatt, JE ;
Cockerill, FR ;
Smith, TF .
CLINICAL MICROBIOLOGY REVIEWS, 2006, 19 (01) :165-+
[24]   Sensitive and rapid amperometric magnetoimmunosensor for the determination of Staphylococcus aureus [J].
Esteban-Fernandez de Avila, Berta ;
Pedrero, Maria ;
Campuzano, Susana ;
Escamilla-Gomez, Vanessa ;
Pingarron, Jose M. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 403 (04) :917-925
[25]   Sensitive optical biosensors for unlabeled targets: A review [J].
Fan, Xudong ;
White, Ian M. ;
Shopova, Siyka I. ;
Zhu, Hongying ;
Suter, Jonathan D. ;
Sun, Yuze .
ANALYTICA CHIMICA ACTA, 2008, 620 (1-2) :8-26
[26]   A Chemically Synthesized Capture Agent Enables the Selective, Sensitive, and Robust Electrochemical Detection of Anthrax Protective Antigen [J].
Farrow, Blake ;
Hong, Sung A. ;
Romero, Errika C. ;
Lai, Bert ;
Coppock, Matthew B. ;
Deyle, Kaycie M. ;
Finch, Amethist S. ;
Stratis-Cullum, Dimitra N. ;
Agnew, Heather D. ;
Yang, Sung ;
Heath, James R. .
ACS NANO, 2013, 7 (10) :9452-9460
[27]   Sub-femtomole detection of 16s rRNA from Legionella pneumophila using surface plasmon resonance imaging [J].
Foudeh, Amir M. ;
Daoud, Jamal T. ;
Faucher, Sebastien P. ;
Veres, Teodor ;
Tabrizian, Maryam .
BIOSENSORS & BIOELECTRONICS, 2014, 52 :129-135
[28]   Modern clinical microbiology: new challenges and solutions [J].
Fournier, Pierre-Edouard ;
Drancourt, Michel ;
Colson, Philippe ;
Rolain, Jean-Marc ;
La Scola, Bernard ;
Raoult, Didier .
NATURE REVIEWS MICROBIOLOGY, 2013, 11 (08) :574-585
[29]   Single-pipetting microfluidic assay device for rapid detection of Salmonella from poultry package [J].
Fronczek, Christopher F. ;
You, David J. ;
Yoon, Jeong-Yeol .
BIOSENSORS & BIOELECTRONICS, 2013, 40 (01) :342-349
[30]   Limitation of a localized surface plasmon resonance sensor for Salmonella detection [J].
Fu, Junxue ;
Park, Bosoon ;
Zhao, Yiping .
SENSORS AND ACTUATORS B-CHEMICAL, 2009, 141 (01) :276-283