Effectiveness and acceptability of a newly designed hip protector: a pilot study

被引:53
作者
Chan, DK
Hillier, G
Coore, M
Cooke, R
Monk, R
Mills, J
Hung, WT
机构
[1] Prince Wales Childrens Hosp, Dept Geriatr Med, Randwick, NSW 2031, Australia
[2] Community Hlth Serv, Aged Care Assessment Team, Orange, NSW, Australia
[3] Prince Wales Childrens Hosp, Dept Orthopaed, Randwick, NSW 2031, Australia
[4] Univ Technol Sydney, FAR, Sch Math Sci, Broadway, NSW 2007, Australia
关键词
novel hip protector; hip fracture; dementia;
D O I
10.1016/S0167-4943(99)00048-5
中图分类号
R592 [老年病学]; C [社会科学总论];
学科分类号
03 ; 0303 ; 100203 ;
摘要
Hip fracture has a significant economic and personal cost, involving hospital admission and functional impairment for elderly people. To assess the benefit of using a newly designed hip protector (new material and new design) to prevent fracture in a realistic setting, a randomised intervention-control design was used to trial the effectiveness of pads worn by high falls risk residents (n = 71) in nursing home for 9 months. 40 residents were in the intervention group and 31 were in the control group. A profile of falls, including time of day, and orientation was obtained to demonstrate the potential effectiveness of the protectors for injury prevention. Acceptance of the hip protector was also surveyed amongst nursing home staff and residents. One hundred and one falls and six fractures occurred in the control group. In contrast, one hundred and ninety one falls and three fractures occurred in the hip protector (pads) group. The three fractures in the protector wearing group occurred when pads were not in place. This was extrapolated as 1 in every 16.8 falls and 1 in every 63.7 falls resulting in fracture in the two groups, respectively. The relative risk of fracture was 0.264 (95% CI = 0.073-0.959) when the fracture incidence rate in the intervention group (three fractures per 191 falls) was compared to the control group (six fractures per 101 falls). This is a statistically significant result and implies that this newly designed hip protector is effective in preventing hip fracture. The majority of falls occurred during the day, which was when protectors were worn in this study, but the data on orientation was incomplete, with direction unknown in 74% of falls. Compliance was an issue, which was interpreted as only 50.3% of falls recorded with protectors in place. Dementia was identified as the explanation for this as the pads were often removed by these residents who comprised the majority of participants. Perception of low risk was the primary barrier to residents accepting the intervention. Comfort of protectors was not a significant concern for staff or residents, and only staff described appearance as an issue. In conclusion, the newly designed hip protector is protective against fractures in a realistic setting. Compliance and acceptance of the protectors will ultimately determine the viability of this prophylaxis. (C) 2000 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:25 / 34
页数:10
相关论文
共 12 条
[1]   The risks of hip fracture in older people from private homes and institutions [J].
Butler, M ;
Norton, R ;
LeeJoe, T ;
Cheng, A ;
Campbell, AJ .
AGE AND AGEING, 1996, 25 (05) :381-385
[2]   EXTERNAL HIP PROTECTORS - LIKELY NONCOMPLIANCE AMONG HIGH-RISK ELDERLY PEOPLE LIVING IN THE COMMUNITY [J].
CAMERON, ID ;
QUINE, S .
ARCHIVES OF GERONTOLOGY AND GERIATRICS, 1994, 19 (03) :273-281
[3]   Case-control study of hazards in the home and risk of falls and hip fractures [J].
Clemson, L ;
Cumming, RG ;
Roland, M .
AGE AND AGEING, 1996, 25 (02) :97-101
[4]   Cohort study of risk of institutionalisation after hip fracture [J].
Cumming, RG ;
Klineberg, R ;
Katelaris, A .
AUSTRALIAN AND NEW ZEALAND JOURNAL OF PUBLIC HEALTH, 1996, 20 (06) :579-582
[5]  
CUMMINGS SR, 1989, J GERONTOL, V44, pM107
[6]   A portable neuromuscular function assessment for studying recovery from hip fracture [J].
Fox, KM ;
Felsenthal, G ;
Hebel, JR ;
Zimmerman, SI ;
Magaziner, J .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1996, 77 (02) :171-176
[7]  
HAYES WC, 1991, ORTHOP RES SOC T, V16, P139
[8]   EFFECT OF EXTERNAL HIP PROTECTORS ON HIP-FRACTURES [J].
LAURITZEN, JB ;
PETERSEN, MM ;
LUND, B .
LANCET, 1993, 341 (8836) :11-13
[9]   Force attenuation in trochanteric soft tissues during impact from a fall [J].
Robinovitch, SN ;
McMahon, TA ;
Hayes, WC .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1995, 13 (06) :956-962
[10]   FALLS IN THE NURSING-HOME [J].
RUBENSTEIN, LZ ;
JOSEPHSON, KR ;
ROBBINS, AS .
ANNALS OF INTERNAL MEDICINE, 1994, 121 (06) :442-451