Qualitative and quantitative analysis of the learning curve of a simulated surgical task on the da Vinci system

被引:128
作者
Hernandez, JD [1 ]
Bann, SD [1 ]
Munz, Y [1 ]
Moorthy, K [1 ]
Datta, V [1 ]
Martin, S [1 ]
Dosis, A [1 ]
Bello, F [1 ]
Darzi, A [1 ]
Rockall, T [1 ]
机构
[1] St Marys Hosp, Imperial Coll Sch Med, Dept Surg Oncol & Technol, London W2 1NY, England
来源
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES | 2004年 / 18卷 / 03期
关键词
minimally invasive surgery; skills assessment; telemanipulator systems;
D O I
10.1007/s00464-003-9047-3
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Robotic telemanipulation systems provide solutions to the problems of less dexterity and visual constraints of minimally invasive surgery (MIS). However, their influence over surgeons' dexterity and learning curve needs to be assessed. We present motion analysis as an objective method to measure performance and learning progress. Methods: Thirteen surgeons completed five synthetic small bowel anastomoses using the da Vinci system. Objective Structured Assessment of Technical Skills (OSATS) allowed qualitative analysis. Quantitative analysis used API software of the system to retrieve real-time robotic signal data of time., path length, and number of movements. Wilcoxon signed ranks test was used for statistical analysis. A p value < 0.05 was considered significant. Results: OSATS global scores were 18.6 points for the first attempt and 26 for the fifth attempt (p < 0.02, Cronbach's alpha = 0.894). Paired data of motion analysis for attempts 1 vs 5 showed significant change: time taken 3507 see and 2287 see (p < 0.008), total number of movements 2411 and 1387 (p = 0.01), total path length 21,630 cm and 13,941 cm (p = 0.01). Conclusions: A rapid learning curve to a competent level using the da Vinci system is possible aided by the system's intuitive motion. Motion analysis is a useful tool to measure performance in the da Vinci system compared to OSATS and time alone.
引用
收藏
页码:372 / 378
页数:7
相关论文
共 34 条
[1]   Robotics and allied technologies in endoscopic surgery [J].
Buess, GF ;
Schurr, MO ;
Fischer, SC .
ARCHIVES OF SURGERY, 2000, 135 (02) :229-235
[2]   The world's first obesity surgery performed by a surgeon at a distance [J].
Cadiere, GB ;
Himpens, J ;
Vertruyen, M ;
Favretti, F .
OBESITY SURGERY, 1999, 9 (02) :206-209
[3]  
Cadière GB, 2001, WORLD J SURG, V25, P1467
[4]  
Cheah W K, 2000, Surg Endosc, V14, P1085
[5]   Robotic surgical training in an academic institution [J].
Chitwood, WR ;
Nifong, W ;
Chapman, WHH ;
Felger, JE ;
Bailey, BM ;
Ballint, T ;
Mendleson, KG ;
Kim, VB ;
Young, JA ;
Albrecht, RA .
ANNALS OF SURGERY, 2001, 234 (04) :475-484
[6]   Robotic-enhanced arterial revascularization for multivessel coronary artery disease [J].
Cichon, R ;
Kappert, U ;
Schneider, J ;
Schramm, I ;
Gulielmos, V ;
Tugtekin, SM ;
Schüler, S .
ANNALS OF THORACIC SURGERY, 2000, 70 (03) :1060-1062
[7]   Initial United States clinical trial of robotically assisted endoscopic coronary artery bypass grafting [J].
Damiano, RJ ;
Ehrman, WJ ;
Ducko, CT ;
Tabaie, HA ;
Stephenson, ER ;
Kingsley, CP ;
Chambers, CE .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2000, 119 (01) :77-82
[8]   Assessing operative skill - Needs to become more objective [J].
Darzi, A ;
Smith, S ;
Taffinder, N .
BRITISH MEDICAL JOURNAL, 1999, 318 (7188) :887-888
[9]   The relationship between motion analysis and surgical technical assessments [J].
Datta, V ;
Chang, A ;
Mackay, S ;
Darzi, A .
AMERICAN JOURNAL OF SURGERY, 2002, 184 (01) :70-73
[10]   The use of electromagnetic motion tracking analysis to objectively measure open surgical skill in the laboratory-based model [J].
Datta, V ;
Mackay, S ;
Mandalia, M ;
Darzi, A .
JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2001, 193 (05) :479-485